Pag. 49/87
INSTRUCTIONS FOR USE
Gas fryer (fig. 15, 16 – pag.6)
To light the burner of the fry top, proceed in the following way:
-
turn the knob (1) from the off position
Q
into the on position ;
-
press down to the bottom;
-
push the button of the piezoelectric lighter (2) to light the pilot burner;
-
keep the knob pressed down until the thermocouple heats up, keeping the pilot lit; this can be
checked through the slit in the control panel;
-
light the main burner, positioning the knob in one of the eight possible positions, choosing the
one most suited to the type of cooking desired, considering that they correspond indicatively to
the temperatures shown below:
To put out the main burner, it is necessary to turn the knob to the right into the on position , to
put out also the pilot, turn the knob again into the off position
Q
.
Gas Fryer with electronic control (fig. 17,18 pag.6)
To light the burners of the gas fryer, proceed in the following way:
-
turn the knob (1) from the off position
Q
to the on position ;
-
press down the button hard;
-
push the button of the piezoelectric lighter (2) to light the pilot burner;
-
keep the knob pressed down until the thermocouple heats up, keeping the pilot lit; this can be
checked through the hole in the combustion chamber;
-
light the main burner to the required setting, by setting the knob to
-
regulate the required temperature by using the knob that controls the thermostat (2).
To turn off the main burner, it is necessary to turn the knob to the right into the position , to turn
off the pilot, turn the knob again, into the off position
Q
.
Normal functioning (fig. 19 pag. 7)
When not in operation the instrument shows the temperature revealed by the probe.
To see the set temperature value, press and release the button UP (1), the led at the bottom, to the
right of the display, flashes showing that a setting is being made. Therefore, if a temperature
modification is required, press the buttons UP (1) or DOWN (2) in 4 seconds and regulate as
required.
To change this operation wait 4 seconds without pressing any buttons or press and release the
MELT button (3) or the START/STOP button (5).
ATTENTION! The firm sets the temperature range, and it varies from a minimum level of 0°C to a
maximum of 195°C.
Before activating this function set the working temperature required, using the UP button (1) to
increase the value or the DOWN button (2) to reduce it. Start the heating by pressing the
START/STOP button (5), then the led START/STOP (6) flashes until a temperature close to the set
Position [N°]
1
2
3
4
5
6
7
Temperature [°C]
100
115
130
145
160
175
190