background image

 

 

 

- 27 - 

Protective devices 

 

Protective function 

 

That function is designed for assuring that the device may be activated only after 
correct placing of the tumbler
 on the motor block (contact with the sensor) and 
after closing both lid clamps.

 

 
 

Overload/overheating protection 

 

 

 

That protection is activated automatically 
in case of motor overheating due too long 
operation or overloading. Wait for the 
device to cool down and press RESET 
button in the bottom (drawing on the left). 

 

Then the blender may be used again.

 

 
 

5. Installation and operation 

5.1 Installation 

 

Positioning 

 

  Unpack the device and remove all packing material. 

 CAUTION! 

  Never remove the rating plate and any warning signs from the device. 

  Place the device on top of an even, stable, and water-resistant surface which 

supports the weight of the device and is not heat sensitive. Moreover the surface 
should be smooth and dry so the front suction cups may be properly attached. 

 

  Never place the device on the table edge to avoid tilting or drop. 

  The operating surface must be easily accessible and large enough. In order to 

assure comfortable operation and proper air circulation leave at least 15 cm of 
space on the sides and back and 50 cm on the front and top from the walls, 
cabinets, etc.

 

  Never place the device in humid or wet environment. 

  Never place the device on the flammable surfaces. 

  Never place the device in the vicinity of open fire, electric ovens, heating furnaces, 

or other heat sources. 

Содержание 150151

Страница 1: ...150151 V1 0315...

Страница 2: ...tection 23 2 3 Declaration of conformity 23 3 Transport packaging and storage 24 3 1 Delivery check 24 3 2 Packaging 24 3 3 Storage 24 4 Technical data 25 4 1 Overview of parts 25 4 2 Technical specif...

Страница 3: ...y and inappropriately All persons using the device must follow the recommendations and instructions in this instruction manual 1 1 Safety instructions Please keep these instructions and give them to f...

Страница 4: ...e cable is damaged If the power cable is damaged have an authorised service center or qualified electrician replace it The device is not adapted for use with an external timer or remote control Never...

Страница 5: ...ct operation damages or dropping on the floor When the cable is damaged it should be replaced by the service company or qualified electrician in order to avoid the hazards The supply cable must be dis...

Страница 6: ...oves when required CAUTION In order to avoid any damages of the device follow the instructions below In order to avoid the damages of the motor block blending tumbler and the knife system do not move...

Страница 7: ...multi blender is designed only for blending preparing shakes puree or drinks CAUTION Any use going beyond the intended purpose and or any different use of the device is forbidden and is not considere...

Страница 8: ...by violation of advice concerning operation and cleaning use other than designed alterations made by user use of inadequate spare parts We reserve the right to make technical changes for purposes of...

Страница 9: ...The outer and inner packing material should be removed completely from the device before installation NOTE If you liked to dispose the packing consider the regulations applicable in your country Supp...

Страница 10: ...l data 4 1 Overview of parts Blending tumbler Transmission coupling Lid Sensor Blending tumbler handle Control panel Protective clamps Motor block Spout with transparent plug Rubber feet Knife install...

Страница 11: ...y 1 second operation 1 second pause 4 2 Technical specification Name Multi blender Code no 150151 Material housing stainless steel plastic blending tumbler plastic nickel chrome steel 18 10 Speed leve...

Страница 12: ...Never remove the rating plate and any warning signs from the device Place the device on top of an even stable and water resistant surface which supports the weight of the device and is not heat sensit...

Страница 13: ...nnect the device directly to the wall socket do not use any extension cords or power strips Place the device so that the plug is easily accessible and can be quickly removed from its socket in case of...

Страница 14: ...tions are illuminated in blue colour and the selected button flashes during the operation The continuous work time for levels 1 3 is 1 minute The device processes the ingredients very quickly After th...

Страница 15: ...motor block by rotating it counterclockwise Empty the tumbler through the spout After use disconnect the device from the socket pull the plug 6 Cleaning CAUTION Disconnect the unit from the power supp...

Страница 16: ...the table below before calling the service company or informing the vendor Problem Cause Solution The device is connected to the power supply but the ON OFF button lamp is not working Plug improperly...

Страница 17: ...sal service in your community WARNING To exclude any abuse and the dangers involved make the waste device unfit for use before disposal For that purpose disconnect device from mains supply and remove...