background image

Pag.  12

3.1 ROUTINE MAINTENANCE

3. 

CLEANING AND MAINTENANCE 

2. 

OPERATING INSTRUCTIONS

2.2 SETTINGS

LIGHTING BURNERS
-   Open main gas tap upstream of appliance.  

-   Press knob and turn from “

closed

” position to “

light/pilot light” 

position

 

and at the same time press the pie-

zoelectric button until the pilot light comes on. The pilot light can be monitored through the inspection hole on 

the control panel.  

  When first starting up, in order to keep the pilot light ON, keep the knob pressed for about 10 seconds. When 

it is released, the pilot light should remain lighted, otherwise, repeat the operation.   

-   To switch on the main pilot light, turn the gas knob from the “

light/pilot light” 

position

 

to the

 

maximum flame” 

position.Adjust the temperature by turning the knob from position 1 to position 7.   

SWITCH-OFF
-   To switch off the main burner and then the pilot light, turn the gas knob to “

light/pilot light” 

and then to

 “clo-

sed”

.

 

 

-   At the end of the working day, switch off the gas check valve upstream of the appliance.  

The control knobs  of the burner taps have two positions:

shut  

lighting / pilot light 

The appliance must be used only for the purpose for which it was designed. Any other use is improper. 

During operation, supervise the appliance.  

2.1  STARTING UP FOR THE FIRST TIME  

Before starting up the appliance for the first time remove all the packing and thoroughly clean the protective 

industrial grease from the appliance  using water and normal detergent.  

BIMETAL PLATE - INSTRUCTIONS FOR USE

When the plate is warm, dampen very slightly with vegetable oil and wait until the plate reaches the desired tem-

perature. For best cooking results, the temperature should be about 240°C - 250°C. The food may be cooked 

on the entire surface of the plate.

At the end of the working day, clean the appliance, both for reasons of hygiene and to prevent operating faults.   

Do not clean the appliance with direct or high-pressure jets of water and do not use metal pads, brushes or scra

-

pers in normal steel. If necessary, use stainless steel pads, but do not rub them against the grain of the metal 

Содержание 131.1413

Страница 1: ...N AND MAINTENANCE MANUAL FOR GAS FRY TOPS MANUEL D INSTRUCTIONS POUR L UTILISATION ET L ENTRETIEN DES FRY TOPS GAZ GEBRAUCHS UND WARTUNGSANLEITUNG FÜR GAS FRY TOPS MANUAL DE INSTRUCCIONES PARA EL USO Y EL MANTENIMIENTO DEL FRY TOP GAS REV 04 2012 COD ZSL6508 131 1413 131 1813 ...

Страница 2: ...n be consulted by different users If the appliance changes owner the user manual must also be transferred to the new owner if necessary request a new copy from the authorised dealer or directly from the manufacturer Only qualified persons must be entrusted with installation operations adapting the appliance to different types of gas commissioning and eliminating system faults All current rules and...

Страница 3: ...t 10 cm away from flammable walls The bain marie may be placed against refractory and non combustible walls Do not obstruct the aspiration or heat di scharge openings and gaps and place the appliance underneath an extraction hood that complies with current standards Fig 1 1 4 CONNECTING GAS INSTALLATION INSTRUCTIONS Installation operations adaptations to other types of gas commissioning and the el...

Страница 4: ...juster in order to ensure optimum operation CHECKING THERMAL POWER During initial installation and during maintenance or adaptation to another type of gas nominal heat input must be measured It can be measured by using the volumetric method with the aid of a litre counter or a chronometer After checking connecting pressure and the diameter of the injectors which must be stamped on the injector mea...

Страница 5: ... operates correctly instruct the user on how to use it Fig 5 1 5 CONNECTING TO A DIFFERENT TYPE OF GAS REPLACING MAIN BURNER NOZZLE Fig 4 1 Burner 2 Nozzle Before adapting to a new type of gas shut off the gas cock upstream Loosen the screws that hold the front control panel in place and disconnect the electric cables of the piezoelectric ignition Loosen the main injectors Ref 2 and repla ce them ...

Страница 6: ...king day switch off the gas check valve upstream of the appliance The control knobs of the burner taps have two positions shut lighting pilot light The appliance must be used only for the purpose for which it was designed Any other use is improper During operation supervise the appliance 2 1 STARTING UP FOR THE FIRST TIME Before starting up the appliance for the first time remove all the packing a...

Страница 7: ...arm soapy water on steel surfaces and then rinse in plenty of water and dry with a soft cloth Maintain the shine by regular polishing with a normal liquid polish Do not wash the work top or floor with hydrochloric acid PLATE In order to remove any encrusted residue scrape with a hard plastic spatula positioned at an angle Clean the plate regularly using a damp cloth After cleaning switch the plate...