user's port and the public grid. The installer or the user of the appliance is
responsible for providing that the appliance is connected to the mains supply
with system impedance Z
sys
is lower or equals Z
max
.
Z
max
Dishwasher
0,21 Ω
Pass-through dishwasher
0,24 Ω
Dishwasher for fitting
0,41 Ω
• Only connection cables, type H07RN-F, may be used; current-carrying capacity
at continuous operation and 60°C at a cord:
Three-phase appliances
o
- 5x2.5 mm^2 up to 20 A
o
- 5x4 mm^2 up to 30 A
o
- 5x6 mm^2 up to 38 A
o
- 5x10 mm^2 up to 54 A
Single-phase appliances
o
- 3x1.5 mm^2 up to 16 A
o
- 3x2.5 mm^2 up to 25 A
• The appliance must be integrated with the potential safety equalization system.
Connection is executed via the screw with 5021 symbol, pursuant to IEC 60417
.
Potential equalization cord cross-section must be 10 mm².