background image

Page. 5 

!

OPERATING INSTRUCTIONS

!

!

The Bartol 

Mag-Probe

" is an 

Instrument f

or 

sensing magnetic fields.

!

!

CAUTION

Damage may result 

if 

the 

"Mag-

Probe" Is 

dropped

.

!

General applications

!

All voltages

 

(AC 

& DC)

!

Solenoids

Solenoid  valves

Relays

Reed

 

relays

Coils,

 

Rotary  solenoids

Stepper 

switches

Detecting 

residual 

magnetism

Coils

Transient 

current  pulses

Identifying

 

North & South poles

etc

.

!

The  white  magnetic  shield  on  the 

Mag-

Probe’s

"

  tip  reduces  the  chance  of 

magnetic  fields  turning  it  on  during 
storage  and  must  be  removed  before 
using.

 

Replace the magnetic shield after 

using

.

!

!

DO  NOT  STORE  THE  “MAG-PROBE"  NEAR  A 
PERMANENT MAGNET OR MAGNETIC FIELD.

!

!

Mag-Probe

"

 

will  not  detect  devices 

enclosed  in  a  magnetic  shield.

 

(most 

devices aren’t shielded

.

)

!

!

You may self test the

 

Mag-Probe

"

 

with the 

High/Low sensitivity ring supplied with each 
unit.

!

!

TESTING AC 

DC DEVICES WITHOUT

!

USING THE 

HIGH/LOW 

SENSITIVITY RING

!

1. Hold  the 

Mag-Probe

"

  as  shown  in 

figure 2.

!

2. Place the tip close to or on the shaft that 

projects through the device’s coil.

!

3. Observe  the  LED  in  the 

Mag-Probe’s

"

 

handle.

!

4. If  the  LED  is  on,the  solenoid  or  relay  is 

energized.

!

5. If the LED is off, the solenoid or relay is 

de-energized.

!

6. If  the  LED  turns  on  and  off,  and  flow 

through the solenoid valve under test is 
not  interrupted,  or  power  through  a 
relay’s  contacts  don’t  turn  on  and  off,  a 
mechanical failure has occurred. 

!

7. If  the  LED  remains  off  during  machine 

operation, two possible problems exist:

!

A. No power to the solenoid or relay.

!

B. An open coil

To  locate  the  problem,  first  test  the 
power  source,  then  the  solenoid  or 
relay coil.

!

8. If transit pulses are suspected, hold the 

Probe tip close to or  on the  solenoid or 
relay  and  observe  the  LED  during  a 
machine  cycle.  If  transit  pulses  are 
present  during  the  time  the  solenoid  or 
relay should be off, the LED will flash on 
and off.

!

With  a  little  practice,  you’ll  know  when  to 
use  the  high/low  sensitivity  ring  in  order  to 
test sub-miniature and smaller devices.

!

!

If you need the added sensitivity, install the 
high/low  sensitivity  ring  according  to  the 
following instructions.

!

Отзывы: