background image

8/28/20 

Home Screen Overview 

 

 

WiFi Status/Button 

Indicates current WiFi status. Green 

bars indicate signal strength. A red X 

indicates no WiFi connection. Press to 

enter the WiFi menu. 

Current Time 

Current time in 

military time. 

Press to change 

time.

 

Headgrower Button 

Press to view options 

for connecting the 
controller through 

Headgrower. Also 

found in the menu. 

 

Menu 

Displays the following 

menu options: 

Settings 

Configuration 

 

Humidity Reading 

Displays the current humidity 

reading. If no sensor is 

attached, it will read 0%. 

 

Force 

Used to manually activate an 

alarm. Will stay active until 

cancelled.   

 

Rain Sensor Reading 

Displays the current rain 

sensor reading. When the 

alarm is active, it will 

change to either be yellow 

(Force) or red (Alarm). 

Light Sensor 

Reading 

Displays the current 

light sensor reading 

in micro moles per 

second per meter 

squared.

 

Wind A2 Reading 

Displays the current status for 

the Wind Activation #2 

Alarm. When the alarm is 

active, it will change from 

Good to either be yellow 

(Force) or red (Alarm). 

 

Outside Temperature

 

Displays the outdoor 

temperature reading. 

Informational only.  

Wind A1 Reading 

Displays the current status for 

the Wind Activation #2 

Alarm. Alarm will displayed as 

pictured when the activation 

speed has been maintained 

for the activate delay time.

 

Block 

Used to block an active alarm 

for 20 minutes before reverting 

back to normal operation.  

 

Wind Speed/Direction

 

Displays the wind speed 

and wind direction (if 

optional directional sensor 

is used). If a standard 

anemometer is used, it will 

always display N (North).  

Содержание WeatherBoss

Страница 1: ...8 28 20 1 WeatherBoss Operation Manual BARTLETT Instrument Co 1032 Ave H Fort Madison IA 52627 319 372 8366 www bartinst com...

Страница 2: ...MENU SCREEN 5 SETTINGS 5 CONFIGURATION 5 SENSOR READINGS 7 RAIN SENSOR 7 WEATHER SENSOR 7 TEMPERATURE SENSOR 8 HUMIDITY SENSOR OPTIONAL 8 LIGHT PHOTO SENSOR OPTIONAL 9 MANUALLY ACTIVATE ALARM 9 BLOCK...

Страница 3: ...e East but a low speed for winds from the West Alarm 2 could be the opposite having a high speed alarm set for wind from the West and low speed alarm from the East This alarm could be assigned to Vent...

Страница 4: ...arm is active it will change to either be yellow Force or red Alarm Light Sensor Reading Displays the current light sensor reading in micro moles per second per meter squared Wind A2 Reading Displays...

Страница 5: ...the Headgrower cloud platform for remote monitoring and control of the WeatherBoss See the WiFi section for more information about firmware updates WiFi Set up Wi Fi for Firmware download and for rem...

Страница 6: ...hannel for the Headgrower app See your Headgrower manual for more information Headgrower ID Displays the HEadgrower ID for your controller This is similar to your controllers serial number and cannot...

Страница 7: ...rection if a standard anemometer is being used High Activation Speed If the wind speed is greater than the High Activation Speed the alarm will activate When the alarm activates the environmental cont...

Страница 8: ...work provided with your humidity sensor needs to be entered into the WeatherBoss Go to Menu Configuration Humidity Cal and enter the 4 digit code provided and press Save If a humidity sensor is not be...

Страница 9: ...larm The Force button may be pressed at any time to activate the output of the Weather Alarm this is a manual override feature The Weather Alarm will close any open vents to the first programmed posit...

Страница 10: ...estore factory default settings The default settings are Activation Set Point 20 MPH Drop Out Set Point 15 MPH Activation Delay 4 Seconds Drop Out Delay 6 Seconds Units English Response Time 1 Wind Al...

Страница 11: ...peed drops below 15 miles per hour for 6 seconds Activation Set Point 20 MPH Drop Out Set Point 15 MPH Activation Delay 4 Seconds Drop Out Delay 6 Seconds 1 Output Off Wind speed is below the activati...

Страница 12: ...ays The WeatherBoss will close any open roof vents to the first programmed position when the when the wind speed exceeds 20 miles per hour The roof vents will return control of the roof vents to the e...