This manual provides the information necessary to help customers connect, install and operate, 
the Mag648 and Mag649™ magnetic field sensors.

Technical specifications of the products, including power supply requirements and analogue 
output details, can be found in 

DS2298

, whilst outline drawings of both sensor head, electronics 

board and cable can be found on the 

Mag648/Mag649 product page

.

1.1. Symbols Glossary

The following symbols used within this manual call your attention to specific types of 
information:

WARNING: 

Indicates a situation in which serious bodily injury or death could result if the 

warning is ignored.

Caution:

 Indicates a situation in which bodily injury or damage to your instrument, or both, 

could result if the caution is ignored.

Indicates a situation in which ESD protection should be used.

Identifies items that must be disposed of safely to prevent unnecessary damage to the 
environment.

Note:

 

A paragraph in this format provides useful supporting information on how to make 

better use of your purchase.

2. Safe Use

WARNING:

 These products are not qualified for use in explosive atmospheres or life 

support systems. Consult Bartington Instruments for advice.

WARNING: 

Environmental and electrical specifications should not be exceeded.

To prevent irreparable damage, electrostatic discharge (ESD) protection and precautions 
must be used when handling the unpackaged sensor electronics board.

Note: Do not expose to strong magnetic fields while being stored as this can magnetise 
the sensor and affect its offset performance.

Содержание Mag648

Страница 1: ...www bartington com INNOVATION IN MAGNETICS OM2298 4 Operation Manual for Mag648 and Mag649 Low Power Three Axis Magnetic Field Sensors...

Страница 2: ...l Description 4 4 1 Vector Measurements and Conventions 4 5 Connections 5 5 1 Cable Recommendations 5 5 2 Connection to Power Supply Acquisition Unit 5 5 4 Mounting Recommendations 6 6 Using the Mag64...

Страница 3: ...s a situation in which bodily injury or damage to your instrument or both could result if the caution is ignored Indicates a situation in which ESD protection should be used Identifies items that must...

Страница 4: ...48 High stability circuitry ensures that a minimum of ten years service should be expected 4 General Description Key 1 Connector cable 2 Sensing Elements 3 Mounting Holes 4 1 Vector Measurements and C...

Страница 5: ...ll cables should be mounted securely in place When designing their own cable the following recommendation should be followed ensure that the cables are shielded to prevent them picking up electromagne...

Страница 6: ...mage to the connector or magnetometer When aligned correctly hand tighten the connector Refer to the product brochure for detailed information Caution For the Mag648U and Mag649U only Allow for recess...

Страница 7: ...not connected or not sufficient to power the sensor Check that the power supply meets the requirement provided in DS2298 and that the connection is as per Connection to Power Supply Acquisition Unit B...

Страница 8: ...e Mag648 and Mag649 probe should be removed using a mild detergent solution only Electronics should be cleaned with an antistatic cloth only ESD protection should be used when handling the electronics...

Страница 9: ...ngland The copyright of this document is the property of Bartington Instruments Ltd Bartington is a registered trademark of Bartington Instruments Limited in the following countries Australia Brazil C...

Отзывы: