background image

Remark: The Remote Control can also be configured for a „No Echo“ mode. In this mode the Remote Control is working like
a „traditional remote  control“ and no reply from the  modules is expected. Using the  „No Echo“ mode only makes sense  if
several Chromoflex RC modules are operated without a „Master“ in one network.

Technical Data

Radio frequency: 868.3 Mhz (license free in EC, Switzerland, Norway and Iceland)

Batteries: 2 batteries, type „Lady“ /„LR03“ /„AAA“ with 1.5 Volt (Alkaline)

Contact / Internet

Download of the PC Software, manuals, data sheets and technical requests (technical requests only as E-mail please!):

www.chromoflex.com , www.barthelme.de 

Manufacturing and distribution:

www.barthelme.de

Setup of the Remote Control

In the setup mode (pressing 

SHIFT

 for > 4 sec), a 5-digit code must be entered, using the buttons 

COL+

 and 

Col-

. Please

press  the  buttons 

COL+

  / 

COL-

  according  to  the  following  table.  We  recommend  to  use  the  modes  with  „Echo“.  Only  if

several modules are operated without a „Master“ in one network, the mode „No Echo“ makes sense. The factory setup is
„Network 8, Echo“:

No:  Code Col+/-  Explanation                          

 0:  - - - - -

No Echo, Normal (Any module), Net 1

 1:  - - - - +

No Echo, Normal (Any module), Net 2

 2:  - - - + -

No Echo, Normal (Any module), Net 3 

 3:  - - - + + 

No Echo, Normal (Any module), Net 4

 4:  - - + - -

No Echo, Normal (Any module), Net 5

 5:  - - + - +

No Echo, Normal (Any module), Net 6

 6:  - - + + -

No Echo, Normal (Any module), Net 7

 7:  - - + + +

No Echo, Normal (Any module), Net 8

 8:  - + - - -

No Echo, Only master, Net 1 

 9:  - + - - +

No Echo, Only master, Net 2

10:  - + - + -

No Echo, Only master, Net 3

11:  - + - + +  

No Echo, Only master, Net 4

12:  - + + - -

No Echo, Only master, Net 5

13:  - + + - +

No Echo, Only master, Net 6

14:  - + + + -

No Echo, Only master, Net 7

15:  - + + + +

No Echo, Only master, Net 8

16:  + - - - -

Echo, Normal (Any module), Net 1

17:  + - - - +

Echo, Normal (Any module), Net 2

18:  + - - + -

Echo, Normal (Any module), Net 3 

19:  + - - + + 

Echo, Normal (Any module), Net 4

20:  + - + - -

Echo, Normal (Any module), Net 5

21:  + - + - +

Echo, Normal (Any module), Net 6

22:  + - + + -

Echo, Normal (Any module), Net 7

23:  + - + + +

Echo, Normal (Any module), Net 8 (** Factory Default **)

24:  + + - - -

Echo, Only master, Net 1 

25:  + + - - +

Echo, Only master, Net 2

26:  + + - + -

Echo, Only master, Net 3

27:  + + - + +  

Echo, Only master, Net 4

28:  + + + - -

Echo, Only master, Net 5

39:  + + + - +

Echo, Only master, Net 6

30:  + + + + -

Echo, Only master, Net 7

31:  + + + + +

Echo, Only master, Net 8