5. CONNECTION 

IMPORTANT: 

The module must be operated with a po-

wer supply that is suitable for the used 
LEDs!

IMPORTANT: 

Improper power supplies may lead to mal-
functions and unwanted flickering effects 

or overheating. We strongly recommend 
using high-quality (stabilized) switching 
power supplies!

We warn against using non-stabilized po-
wer supplies. We recommend switching 
power supplies. Even LED power supplies 

are not recommended, because some are 
already equipped with control electronics 

for constant current, which will destroy 
the electronics of CHROMOFLEX Pro.

6. OPERATION 

Please operate this unit only when it is 
working properly.
In case of an error, switch off the unit im-
mediately. Do not operate the unit until the 
unit was verified electronically by a quali-
fied electrician.

A case of error is:

•  Visible signs of damage on the unit
•  The unit is not operating properly
•  Rising smoke or crackling sounds from 

the unit 

•  Visible signs of overheating

Maintenance and service which require 

access to live components inside the unit 
must be carried out by an authorized elec-

trician.

WARNING: risk of electric shock!

One power supply can be used for several 
units in parallel if the maximum output po-
wer of the supply is observed.

This model does not have any internal cur-
rent regulator. Supply voltage is passed th-
rough and the voltage of the power supply 
must match the voltage of the LED strip.

NOTE: 

LED stripes of 10 volts, 12 volts and 24 

volts are offered on the market. Depending 
on the length the LED stripes might need 
very high currents.

How to avoid malfunctions or fire risk:

•  Do not affect air circulation by covering 

the unit.

•  Do not attach anything to the unit e.g. de-

coration items etc.

•  Do not let your children play unattended 

with electrical equipment. Children can-
not always perceive possible dangers 
correctly. 

POWER IN

GND

+8… 26 V DC

COM

W

COM+

B

W-

R

B-

G

R-
G-

Antenna 

Do not cut!

EXAMPLE: CONNECTION 4 CHANNEL

7. CONTENTS

Every CHROMOFLEX Pro Luminaire unit is 

shipped with this manual. The instructions 
are an integral part of the equipment to 
which they relate and must be handed to 

the user.

CHROMOFLEX Pro Glas Touch RGBW 
(66000336, 66000337), CHROMOFLEX Pro 
remote control RGB (6600045), CHRO-
MOFLEX Pro USB dongle (66000036) 
und the CHROMOFLEX Pro Wallswitch 
(Art.66000373) are optional accessories.

IMPORTANT NOTE:

 

Complete manuals for any CHROMOFLEX 
can be downloaded at 

www.barthelme.de

 

Please look for updates before installation.

4. INSTALLATION

The electric wiring/connection must 
comply with all current and valid national 
requirements, be constructed by a cer-

tified electrical tradesman, and comply 
with all the requirements set forth in this 
planning manual. 

ATTENTION: 

Disconnect the system and the device be-
fore beginning any work! 

ASSEMBLY SITE 

The unit is suitable for assembly in profiles, 

it is important not to shield the antenna, it 

can affect wireless signal range.

In operation the unit might produce heat. 
Care must be taken to provide unrestricted 

air ventilation.