EX port parameters
Explosion protection
IEC
Parameters
USA
Parameters
USB (magnetic
connector)
SIM (1&2)
card
SD card
Unit
U
o
V
oc
5.45
5.45
5.45
V
I
o
I
sc
2.81
1.20
7.04
A
P
o
P
out
0.84
0.41
2.59
W
C
o
C
a
N/A
27.40
39.30
μF
L
o
L
a
N/A
24.97
0.72
μH
USB U
i
and device U
m
(non-hazardous area connection only) = 12V.
ATEX Zone 1 / 21
Type
17-S13*-1***/*********
Marking
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135°C Db
-20°C
≤
Ta
≤
+60°C
Test certificate
CSANe 20ATEX4223X
IECEx Zone 1 / 21
Type
17-S13*-1***/*********
Marking
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db
-20°C
≤
Ta
≤
+60°C
Test certificate
IECEx SIR 20.0036X
NEC 500/505
Type
17-S13*-1***/*********
Marking
Class I; Division 1; Groups A, B, C and D; T4
Ex ia IIC T4 Ga
Class I, Zone 0, AEx ia IIC T4 Ga
Test certificate
CSA 22CA80042090X
Temperature range
ATEX/IECEx (EN IEC 60079-0)
-20 °C
≤
Ta
≤
+60 °C (-4 °F
≤
Ta
≤
140 °F)
Discarge (EN IEC 62368-1)
-20 °C
≤
Ta
≤
+50 °C (-4 °F
≤
Ta
≤
122 °F)
Charging (EN IEC 62368-1)
0 °C
≤
Ta
≤
+45 °C (32 °F
≤
Ta
≤
113 °F)
Long term storage
0 °C
≤
Ta
≤
+35 °C (32 °F
≤
Ta
≤
95 °F)