1. Assembly Housing 

 
 

1.1  

BRICK 

 

 
1)  

 

Drill 7 holes (1,0mm ) and 4 holes (5,5mm) with the 
fixture in the lower housing.  
Press 4 inserts into the big holes. 
 
 

2)  

 

Lead the 7 wires (each with different colour) through the 
drillings. 
 
(LiY 0.08mm², d

iso 

> 0.2mm) 

 
 

3)  

 

Fill the RFID upper housing with Sikaflex as shown in 
the picture. 
 

4)  

 

Fix the RFID lower housing with 4 screws and 4 
washers on the housing. 
 

5)  

 

Seal the screw heads and the wire openings with 
Sikaflex. 
 

 

Содержание MC9000ex Series

Страница 1: ...Integration Manual BARTEC Blatt 1 9 MC9000ex Series Mobile Computer MC92NOex RFID ...

Страница 2: ...er housing Press 4 inserts into the big holes 2 Lead the 7 wires each with different colour through the drillings LiY 0 08mm diso 0 2mm 3 Fill the RFID upper housing with Sikaflex as shown in the picture 4 Fix the RFID lower housing with 4 screws and 4 washers on the housing 5 Seal the screw heads and the wire openings with Sikaflex ...

Страница 3: ...ress 4 inserts into the big holes Lead the 7 wires each with different colour through the drillings LiY 0 08mm diso 0 2mm 2 Fill the RFID upper housing with Sikaflex as shown in the picture 3 Fix the RFID lower housing with 4 screws and 4 washers on the top housing 4 Seal the screw heads and the wire openings with Sikaflex ...

Страница 4: ...er housing Solder appropriate wires on the LF board as shown in the picture and fix them with UV glue Apply Sikaflex in the sealing area of the housing 2 Put the RFID lower housing on the upper housing and press them together 3 Apply the opening of the lower housing with Sikaflex 4 Lock the opening with the according cover ...

Страница 5: ... wires on the HF board as shown in the picture and fix them with UV glue Apply Sikaflex in the sealing area of the housing 2 Put the RFID lower housing on the upper housing and press them together 3 Fill the resin into the RFID housing without empty space and apply the opening of the lower housing with Sikaflex 4 Lock the opening with the according cover ...

Страница 6: ...ard as shown in the picture and fix them with UV glue Apply Sikaflex in the sealing area of the housing 2 Put the RFID lower housing on the upper housing and press them together 3 Fill the resin into the RFID housing without empty space and apply the opening of the lower housing with Sikaflex 4 Lock the opening with the according cover ...

Страница 7: ...able of the external antenna through the opening of the RFID lower housing 3 Fix the RFID lower housing and external antenna with 4 washers and 4 screws 4 Seal the screw heads and antenna cable passage with Sikaflex 5 Position the UHF Reader on the according pins and fix it with Sikaflex Apply Sikaflex in the sealing area of the housing ...

Страница 8: ...he picture and fix it with UV glue Secure the connector with Sikaflex 7 Put the RFID lower housing on the upper housing and press them together 8 Fill the resin into the RFID housing without empty space and apply the opening of the lower housing with Sikaflex 9 Lock the opening with the according cover ...

Страница 9: ...BRICK 1 Lay the top housing on the bottom housing and slide it in the way of the arrow 2 Also for the external antenna versions 3 2 GUN 1 Lay the top housing on the bottom housing and slide it in the way of the arrow 2 Also for the external antenna versions ...

Отзывы: