Align the trace heater exactly and fix it firmly to the bases and the cylinder using additional fixing straps.
To avoid damage to the trace heater. make sure that the fixing straps are not tightened too firmly. It should be possible to move the trace
heater slightly under the fixing straps.
The distances between the fixing straps should not exceed 250 mm.
Finally, place aluminium tape on areas of loose contact of the trace heater.
This step improves heat transfer and prevents insulating material being trapped between the trace heater and the tank.