background image

Scope : 

USER MANUAL 
DE8-BC Ex d Empty Enclosure 

 

      

 

Date: 

02.04.2022 

Ver.: 

QA Code: 

5

 

Checked by: 

E.T. 

Approved by: 

S.Gr. 

Page: 

of 8

 

Document no. : 

21469 

 
 

The passing on and copying of this document and the use or communication of it’s contents are forbidden without express authority. 
Offenders are liable to payment of damages. All rights are  reserved in the event of the registration of a patent . 

Example of the type label that shall be mounted inside the enclosure: 

 

 

Description of the component 

Our  DE8-BC  range  of  flameproof  enclosures  is  available  in  many  sizes.  They  are  made  of 
welded  and  machined  acid  resistant  stainless  steel  316L  or  painted  carbon  steel.  Each  is 
expected  to  receive  electrical  components  inside,  making  service  and  maintenance  easy. 
They  can  also  be  customized  to  meet  each  individual  specific  need.  If  necessary,  multiple 
enclosures can be assembled on a frame with or without combined Ex e junction boxes. 
 

The enclosures are delivered with Ex Component certificate (U-certificate) to be used 
as basis for further certification of an Ex Equipment or Protective System.

  

 
Meaning of symbols 

 

This symbol means a hazard and precaution to be taken 

Safety instructions  

The  device  must  be  installed,  used  and  maintained  in  accordance  with  the  following 

standards: 
 

  IEC/EN 60079-0 (Explosive atmospheres - Part 0: 

Equipment - General 

requirements

  IEC/EN 60079-1 (Explosive atmospheres - Part 1: Equipment protection by 

flameproof enclosures "d") 

  IEC/EN 60079-14 (Explosive atmospheres - Part 14: Electrical installations design, 

selection and erection) 

  IEC/EN 60079-17 (Explosive atmospheres - Part 17: Electrical installations inspection 

and maintenance) 

  IEC/EN 60079-31 (Explosive atmospheres - Part 31: Equipment dust ignition 

protection by enclosure "t") 

  Decrees, orders, laws, directives, circulars, applications, standards, state of art and 

other documentation relating to its installation site 

It is forbidden to change anything without the prior written consent of Bartec 

Technor unless the enclosure undergoes a full Equipment certification at a Notified 
Body/Certification Body. 

 We cannot accept any responsibility for failure to observe these regulations: 

 

  Make  sure  of  the  compatibility  between  the  information  on  the  nameplate,  the 

explosive atmosphere present, the area of use and ambient temperatures on surfaces 

  Any damage on the device can cause the flameproof protection to become ineffective 

  The installation of the enclosure must be done in the state of the art in the technical 

domains and only by qualified, competent and empowered personnel 

Содержание DE8-BC Series

Страница 1: ...S Gr Page 1 of 8 Document no 21469 The passing on and copying of this document and the use or communication of it s contents are forbidden without express authority Offenders are liable to payment of...

Страница 2: ...d for use in potentially explosive atmospheres and certified according to the requirements of the ATEX Directive and IECEx Parameters relating to safety Maximum current 1000 A Maximum DC voltage 1000...

Страница 3: ...ructions The device must be installed used and maintained in accordance with the following standards IEC EN 60079 0 Explosive atmospheres Part 0 Equipment General requirements IEC EN 60079 1 Explosive...

Страница 4: ...the carrier Do not put damaged products into service Packaging Location storage Duration storage Open In a covered location clean without contact with external substances and closed with temperature a...

Страница 5: ...5 192 274 346 12 14 x M12 35 85 DE8BC 351D 358 478 471 33 250 350 225 192 274 346 12 14 x M12 35 98 DE8BC 43 438 538 321 40 380 400 300 252 334 526 12 14 x M12 35 122 DE8BC 43D 438 538 472 63 380 400...

Страница 6: ...Nm 20 C 40 C Qty x L 20 C 40 C DE8BC 32 800 800 12 x M12 35 74 74 DE8BC 32D 800 800 12 x M12 35 74 74 DE8BC 351 800 800 14 x M12 35 74 74 DE8BC 351D 800 800 14 x M12 35 74 74 DE8BC 43 800 800 14 x M1...

Страница 7: ...s A C Sides B D Max 2 Sides A C Sides B D Max 2 DE8BC 32 12 12 32 8 8 20 3 3 12 1 1 4 DE8BC 32D 12 12 32 8 8 20 3 3 12 1 1 4 DE8BC 351 12 12 24 8 8 18 3 3 8 1 1 4 DE8BC 351D 12 12 24 8 8 18 3 3 8 1 1...

Страница 8: ...the content of the Ex component enclosure equipment may be placed in any arrangement provided that an area of at least 20 IIB or 40 IIB H2 of each cross sectional area remains free The length of flame...

Отзывы: