background image

 

 

   

 

 

Operational Instruction 

(Translation)

 

  Miniature Control and Display Unit  

Type 07-61.1-…./…. 

 

 

BARTEC 

GmbH  Max-Eyth-Straße 16  

97980 Bad Mergentheim 

Germany 

Tel.:  +49 7931 597-0 

Fax:  +49 7931 597-119 

[email protected] 

www.bartec.de 

Reservation  Technical data subject to change without notice. Changes, errors and 

misprints may not be used as a basis for any claim for damages. 

EN 2/4 

 

 

01-6100-7D0002/

B-0

2/

15-STVT-283184

 

Safety Instructions 

The miniature control and display unit may be 
used only within the specified temperature
class and the temperature range indicated for it
(see type label). The miniature control and
display unit is not suitable for use in Zones
0/20.  
The miniature control and display unit may be 
operated only if it is clean and not damaged in
any way. Dust deposits > 5 mm (> 0.2 in) must
be removed. 
Utilization in areas other than those specified
and the opening or modification of the product
by anyone other than the manufacturer are not
permitted and will exempt BARTEC from lia-
bility for defects and any further liability. 
The generally applicable statutory rules and
other binding directives relating to workplace
safety, accident prevention and environmental
protection must be observed. 
When using electrical systems, the relevant
installation and operating conditions must be
observed. The specifications on the type label
must be adhered to. 
Observe the applicable laws and directives
when commissioning or restarting operation. 
Always follow the safety instructions on the
operating equipment. 
 

Marking 

Particularly important points in these instruc-
tions are marked with a symbol: 

 

 

DANGER indicates a hazardous situation
which, if not avoided, will result in death or 
serious injury. 

 

WARNING indicates a hazardous situation 
which, if not avoided, could result in death or 
serious injury. 

 

CAUTION indicates a hazardous situation
which, if not avoided, could result in minor or 
moderate injury.  

 

NOTICE is used to address practices not 
related to personal injury. 

 

 

Note 

Important instructions and information on
effective, economical and environmentally
compatible handling. 

 

Standards conformed to 

EN 60079-0:2012/IEC 60079-0 : 2011 
EN 60079-1:2007/IEC 60079-1 : 2007-04 
EN 60079-7:2007/IEC 60079-7 : 2006-07 
EN 60079-11:2012/IEC 60079-11 : 2011 
EN 60079-31:2009/IEC 60079-31 : 2008 

 

ABNT NBR IEC 60079-0 
ABNT NBR IEC 60079-1 
ABNT NBR IEC 60079-7 
ABNT NBR IEC 60079-11 
ABNT NBR IEC 60079-31 

 

as well as 

 

EN 60204-1:2006/IEC 60204-1:2005, mod. 
EN 62208:2011/IEC 62208:2011 
EN 60445:2010/IEC 60445:2010 
EN 60529:1991 + A1:2000 + A2:2013/ 
IEC 60529:1989 + A1:1999 + A2:2013 
 

 

Note 

See the separate installations documentation
for standards for the installed parts.

 

 

Transport, storage 

 

Damage to the miniature control and display 
unit through incorrect transport or incorrect 
storage. 

 

Transport and storage is permissible in
original packaging only. 

 

Assembly / disassembly 

 

Risk of serious injury due to incorrect 
proceedings. 

 

Only authorized and qualified personnel 
may do any of the assembly, disassembly,
installation and commissioning work. 

 

Always disconnect the miniature control 
and display unit from voltage before as-
sembly/disassembly. 

 

Follow the components mounting instructi-
ons/operating instructions. 

When assembling the miniature control and 
display unit, take care that the distances be-
tween the outside edge of the flame-proof gap 
and the fixed obstacles that are not part of the
miniature control and display unit are for: 

 

Gas/vapour sub-group 

IIC IIB 
at least 40 mm 
(1.58 in) 

at least 30 mm 
(1.18 in) 

 

 

Property damage caused by unsuitable 
connection cables. 

 

Select the quality of the connection cable
so that it corresponds to the thermal and
mechanical requirements of the respective
range of application. 

In hazardous areas the connection cable must
be laid in a way that ensures it will be protected
from damage and it will be mechanically fail-
proof.  
 

 

 

Note 

For miniature control and display units set up 
outdoors, it may be necessary to implement 
measures to ensure operation in accordance 
with the intended purpose (e.g. shelter from the 
rain or an outer enclosure with a suitable 
protection class). 

 

Installation 

 

Death or serious injury through improper 
use. 

 

Extensions or modifications to the minia-
ture control and display unit are only per-
missible if the manufacturer’s approval is 
obtained first. 

 

IEC/EN60079-14 must be observed. 

 
Check when installing: 

 

When connecting cables and conductors 
to operating equipment with the “Ex e” 
type of protection, use Ex-certified cable 
entries that are suitable for the respective 
types of cables and conductors. They 
must conform to the “Ex e” type of protec-
tion and have a suitable sealing element 
uphold the miniature control and display 
unit’s protection class. 

 

Connect metallic cable entries to the 
earthing system. 

 

Seal unused cable entry holes with Ex-
certified stopping plugs.  

 

When connecting directly to the flame-
proof enclosure, use Ex-certified entries 
that are suitable for the enclosure capaci-
ty, the gas sub-group and the conductor. 

 
Take care when connecting conductors: 

 

Always use suitable crimping tools when 
crimping the wire-end ferrules to ensure a 
consistent quality of pressing each time.  

 

Take care not to damage the individual 
wires. 

 

Tighten all terminal points securely (in-
cluding those not in use). 

 

Commissioning 

Before commissioning, check that: 

 

The miniature control and display unit has 
been installed in compliance with regula-
tions. 

 

The enclosure is not damaged. 

 

The connection has been established 
properly. 

 

The cables have been laid correctly. 

 

All screws have been tightened securely. 

 

The miniature control and display unit
functions perfectly. 

 
 

 

Содержание 07-61.1 Series

Страница 1: ...rial Aluminium surface bare coated Stainless steel Brass surface bare nickel plated Cover closure Cheese head screw ISO 4762 M4x14 A2 70 or ISO 4762 M5x14 A2 70 Dimensions See page 3 01 6100 7D0002 B 02 15 STVT 283184 Note on instructions When working in hazardous areas the safety of personnel and equipment depends on compli ance with the relevant safety regulations The people in charge of install...

Страница 2: ...display unit through incorrect transport or incorrect storage Transport and storage is permissible in original packaging only Assembly disassembly Risk of serious injury due to incorrect proceedings Only authorized and qualified personnel may do any of the assembly disassembly installation and commissioning work Always disconnect the miniature control and display unit from voltage before as sembly...

Страница 3: ...spect the threaded gap Visually inspect the flameproof encapsu lation for damage Check sealings for effectiveness Replace old or damaged sealings with new original seals Check that the connecting terminals cable conductor entries are secure Note In the course of maintenance particular atten tion must be paid to checking that the parts essential for the type of protection and proper functioning are...

Страница 4: ...ax Eyth Straße 16 97980 Bad Mergentheim Germany Tel 49 7931 597 0 Fax 49 7931 597 119 info bartec de www bartec de Reservation Technical data subject to change without notice Changes errors and misprints may not be used as a basis for any claim for damages EN 4 4 01 6100 7D0002 B 02 15 STVT 283184 ...

Отзывы: