RDG603A73 - Issue 3
Page 39 of 96
SECTION 6
– Operation
NOTICE:
REFER TO THE SHIRE MANUAL PRIOR TO STARTING THE ENGINE.
1. Starting the engine for the first time
•
Remove ignition key.
•
Ensure all oil and coolant levels are checked.
•
Ensure both the engine and domestic batteries are connected. Both battery master
switches must be turned on. Failure to do so may damage the domestic alternator.
•
Ensure that the raw water seacock is turned on.
2. Starting Procedure
•
Ensure there is no one in the engine compartment.
•
Ensure the engine compartment door is closed.
•
Ensure the gearshift control level is set to neutral and that all persons are clear of any
moving parts.
•
Insert ignition key.
•
Turn key to on position. The glow plug light will illuminate.
•
Observe warning lights (and gauges on deluxe panel). Note: The engine water
temperature overheat warning light will only come on for a brief period of time when
the ignition is first turned on as a bulb check. It will then only illuminate in the case of
the engine coolant temperature exceeding the maximum safety level.
•
Wait for the glow plug light to go out.
•
Turn key to start and hold to crank.
•
Crank the engine for no more than 15 seconds.
•
Upon engine start, immediately release the key.
•
Key will return to on position.
•
The warning buzzer will stop and on the deluxe panel, the oil pressure gauge will show
an oil pressure of 2.5 - 3.5 bar (36 - 51 psi).
•
Should any warning light not go out, or if there is no reading on the oil pressure gauge,
the buzzer will continue sounding. In this case, stop the engine immediately and check
the relevant system (Note: If the charge light does not go out, briefly increase the
engine speed).
•
Once started check that sea water is coming out of the water cooled exhaust outlet in
the hull of the boat.