INSTALLATION INSTRUCTIONS
800.533.3948 • www.barronltg.com
3
40070017 REV 1 01/2019
ACCESSORIES
(insert 3528 or 5050 for the **** for the correct version)
• RFX-CSS-**** is designed to join (2) cut sections together. (Fig. 2)
• RFX-CSS-FLEX-**** is designed to join (2) cut sections together with 2”
wire spacing, allowing the FTK tape to bend or turn corners. (Fig.3)
• RFX-CSP-**** is designed to provide wire leads to a cut section of FTK
tape to assist with connection to the driver. (Fig. 4)
NOTE:
• When connecting lengths together keep all negatives (-) on one side and all
positives (+) on the other. Failure to do so will leave a non-working section.
(Fig. 5)
• Peel the silicon sleeve back approximately 1/8” and slide the tape under the
connector terminals, aligning the copper pads with the terminal prongs.
Snap cover down to secure the FTK tape in place. (Fig. 6)
TROUBLE SHOOTING
Product will not light:
• Verify that there is power to the receptacle feeding the product.
• Check the GFCI and see if it is tripped.
• Check the driver and make sure it has power.
• Verify product porlarity is correct.
Product does not light for the first 8”- 30”:
• Product was cut incorrectly. It will be necessary to re-cut the product at the
correct designated locations and reassemble.
Product has a dark section in the run:
• This indicates the product was pulled, twisted or kinked and the circuitry
was damaged.
• It will be necessary to cut new product or cut out the damaged section and
splice a new piece in its place.