background image

Barracuda CloudGen Firewall

F400 Revision C

4 / 7

Energy efficiency [average]

> 85%

The hardware specifications list was valid at the time this manual was published. The listed
components are subject to change at any time, as Barracuda Networks may change hardware
components due to technological advancements. Therefore, the list may not reflect the current
hardware configuration of the Barracuda appliance it was delivered with.

LEDs and Acoustic Signals

Your appliance is equipped with a variety of LEDs. The tables below show the different meanings of
the different glowing states and acoustic signals:

LED Color

Status

Meaning Installation

Meaning Operation

All LEDs Off

Off

Appliance is powered off or
installation has not initialized
far enough for LED control
when installation is started.

Appliance is powered off.

Power LED front side -
GREEN

Steady

Installation was completed
successfully, appliance is halted
for reboot or installation was
not yet initialized far enough for
LED control.

Appliance is plugged in and
is on.

Status LED front side -
GREEN/RED

Off

Installation has not initialized
far enough for LED control
when installation is started.

-

Status LED front side -
GREEN

Steady

Installation was completed
successfully, appliance is halted
for reboot.

Appliance is up and running.

Status LED front side -
GREEN

Blinking

Normal installation.

Appliance is either booting,
shutting down, or
performing a system
update.

Status LED front side -
RED

Steady

-

Appliance is halted and may
be disconnected.

Status LED front side -
RED

Blinking

Error during installation.

An error has appeared
preventing the appliance
from entering the up state.

Status LED front side -
RED/GREEN

Steady

-

Appliance is in 

ART

 mode.

Disc LED front side -
YELLOW

Blinking

Appliance is reading or writing
on storage.

Appliance is accessing the
internal storage.

Содержание CloudGen F400 C Standard Model

Страница 1: ...s and a single power supply Other F400 C model types F20 provide di erent port combinations and a dual power supply F400 C Standard Model Port Con guration Port Label OS Notation Speed Type Management...

Страница 2: ...cal Fiber SFP A1 a1 10 GbE Optical Fiber SFP A2 a2 10 GbE Optical Fiber SFP The CloudGen Firewall hardware appliances ship with a Quick Start Guide Follow this guide to connect to your rewall To prote...

Страница 3: ...an Power supply F400 F400 F20 Single internal Dual hot swap internal Environmental Noise emission db A N A Operating temperature C 0 to 40 Storage temperature C 20 to 70 Operating humidity non condens...

Страница 4: ...o Power LED front side GREEN Steady Installation was completed successfully appliance is halted for reboot or installation was not yet initialized far enough for LED control Appliance is plugged in an...

Страница 5: ...ow and or red LED colors Depending on the appliance type the status LED might be on by default and it might take some time during boot and installation to start either blinking or changing the color F...

Страница 6: ...nd date currently con gured on the appliance Uptime of Barracuda OS The uptime in days hours and minutes Serial number of the appliance Unique identi er for the appliance Shutdown menu Enables you to...

Страница 7: ...c No portion of this document may be copied distributed publicized or used for other than internal documentary purposes without the written consent of an o cial representative of Barracuda Networks In...

Отзывы: