background image

3

USER GUIDE

Congratulations on your purchase of a Barnes 
grinder pump system. With proper care and by 
following a few simple guidelines your grinder 
pump will give you many years of dependable 
service.

Use and Care

The grinder pump station is designed to 
handle routine, domestic sewage. Solid waste 
materials should be thrown in the trash. While 
your station is capable of accepting and 
pumping a wide range of materials, regulatory 
agencies advise that the following items should 
not be introduced into any sewer either directly 
or through a kitchen waste disposal:

• Glass
• Metal
• Diapers
• Socks, rags or cloth
• Plastic objects (e.g., toys, utensils, etc.)
• Sanitary napkins or tampons

In addition you must 

NEVER

 introduce into any 

sewer:

• Explosives
• Flammable Material
• Lubricating Oil and/or Grease
• Strong Chemicals
• Gasoline

General Information

Your home wastewater disposal service is 
part of a low pressure sewer system. The key 
element in this system is the Barnes grinder 
pump station. The basin collects all wastewater 
from the house. The solids in the sewage are 
then ground to a small size suitable for pumping 
in the slurry.

The grinder pump generates suf

fi

 cient pressure 

to pump this slurry from your home to the 
wastewater plant.

Power Failure

Your grinder pump cannot dispose of wastewater 
or provide an alarm signal without electrical 
power. If electrical power service is interrupted, 
keep water usage to a minimum.

Warranty

Your grinder pump is furnished with a warranty 
against defects in material or workmanship. A 
properly completed 
Start-Up/Warranty Registration form must be 
on 

fi

 le at the Barnes factory in order to activate 

your warranty. In addition your pump must be 
installed in accordance with the installation 
instructions.
If you have a claim under the provisions 
of the warranty, contact your local Barnes 

 

Distributor.
When contacting your representative for service, 
please include your station serial number, 
pump model number, and pump serial number.

For future reference, record the following 
information:

Station Serial No:

Pump Model No:

Pump Serial No:

Local Distributor:

Distributor Telephone:

Professional Plumbing

Содержание PGPH Series

Страница 1: ...ystems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax...

Страница 2: ...NG Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected Make sure lifting handles are securely fastened each time before lifting Do not operate pump without...

Страница 3: ...der pump station The basin collects all wastewater from the house The solids in the sewage are then ground to a small size suitable for pumping in the slurry The grinder pump generates sufficient pres...

Страница 4: ...N Hardware 300 series stainless steel CORD ENTRY 30 Ft 9 1m 15 Ft 4 5m Cord on Compact series CC CE CT Custom Molded Quick Connected for sealing and strain relief CORD CSA UL Approved 12 3 12 5 Type S...

Страница 5: ...t 10 voltage at motor Recommended Breaker Heater Sizes Pump Model HP Phase Volts Breaker Size All PGP Series Pumps 2 1 240 25 AMP The nameplate is located on top of the pump This contains the pumps pa...

Страница 6: ...owline knot where shown per the directions provided Steps 1 through 5 On the CT Not Shown series tie bowline knot on the eyebolt On the L and AUE series tie bowline knot on the lifting handle See Fig...

Страница 7: ...n Ontario Canada 905 457 6223 INSTALLATION Location The pump is designed with pipe legs to keep a minimum of 3 inch clearance THIS PUMP MUST BE INSTALLED WITH A MINIMUM OF 3 INCHES CLEARANCE UNDER THE...

Страница 8: ...female end of cord plug into housing bore aligning alignment mark with hole in terminal block see Figure 4 Tighten bolts on compression flange until flush with motor housing FIGURE 4 OGV L Single phas...

Страница 9: ...freedom of operation 7 Open valve 8 Check cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verif...

Страница 10: ...10 FIGURE 6...

Страница 11: ...0395SD Seal outer Silicon Carbide STD 22 A R Permatex Sealent 2C 23 1 016079 Shim set 24 3 Qts 029034 Cooling Oil Mtr Housing 25 1 095368 Square Ring 26 4 1 300 1 Screw 5 16 18 x 1 25 SS ITEM QTY PART...

Страница 12: ...Notes...

Страница 13: ...XVW EH VLJQHG E RXU DXWKRUL HG UHSUHVHQWDWLYH XH WR LQDFFXUDFLHV LQ HOG WHVWLQJ LI D FRQ LFW DULVHV EHWZHHQ WKH UHVXOWV RI HOG WHVWLQJ FRQGXFWHG E RU IRU XVHU DQG ODERUDWRU WHVWV FRUUHFWHG IRU HOG SHU...

Страница 14: ...t To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by th...

Страница 15: ..._ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating _______________...

Страница 16: ...FRQWUROV LQVWDOOHG DZD IURP WXUEXOHQFH 6BBB 12BBB V OHYHO FRQWURO RSHUDWLQJ SURSHUO 6BBB 12BBB V SXPS IXOO VXEPHUJHG GXULQJ RSHUDWLRQ 6BBB 12BBB ROORZ XS RUUHFWLYH FWLRQ 5HTXLUHG 6BBB 12BBB GGLWLRQDO...

Отзывы: