Barnes 44CDD6 Скачать руководство пользователя страница 5

5

SECTION B: GENERAL INFORMATION

B-1)  To the Purchaser:

Congratulations! You are the owner of one of the fi nest 
pumps on the market today. Barnes® Pumps are products 
engineered and manufactured of high quality components. 
Over one hundred years of pump building experience 
along with a continuing quality assurance program combine 
to produce a pump which will stand up to the toughest 
applications.

This Barnes Pumps manual will provide helpful information 
concerning installation, maintenance, and proper service 
guidelines.

B-2) Receiving

Upon receiving the pump, it should be inspected for 
damage or shortages. If damage has occurred, fi le a claim 
immediately with the company that delivered the pump. If 
the manual is removed from the packaging, do not lose or 
misplace.

B-3) Storage:
Short Term -

 Barnes Pumps are manufactured for effi cient 

performance following long inoperative periods in storage. 
For best results, pumps can be retained in storage, as factory 
assembled, in a dry atmosphere with constant temperatures 
for up to six (6) months.

Long Term -

 Any length of time exceeding six (6) months, but 

not more than twenty four (24) months. The units should be 
stored in a temperature controlled area, a roofed over walled 
enclosure that provides protection from the elements (rain, 
snow, wind blown dust, etc..), and whose temperature can be 
maintained b40 deg. F and +120 deg. F.
If extended high humidity is expected to be a problem, all 
exposed parts should be inspected before storage and all 
surfaces that have the paint scratched, damaged, or worn 
should be recoated with a water base, air dry enamel paint. 
All surfaces should then be sprayed with a rust-inhibiting oil.

B-4) SERVICE CENTERS:

For the location of the nearest Barnes Service Center, check  
representative or Carane Pumps & Systems, Inc. Service 
Department in Piqua, Ohio, telephone (937) 778-8947 or 
Crane Pumps & Systems Canada Inc., Bramton, Ontario 
(905) 457-6223.

SECTION C: PREPARE PUMP FOR OPERATION:

1.  See Engine Manufacturer’s instruction manual for
 

quantity, grade and viscosity of oil and change interval.

 

Fill engine crankcase with amount needed. and check 

 

oil level frequent. Fill tank per manufacturer,s

 

recommendations. Be familiar with engine 

START UP

 

 and 

SHUT DOWN

 procedures before operation. 

 

Operate engine in accordance with the manufactures

 instructions.
2.  Turn down all grease cups on the pump. Keep the cups
 

full of good clean grease - Exxon Ronex MP or equal.

3.  For best performance locate pump as close to water as
 

possible. Vertical suction lift should not exceed 

 

25 ft. (7.6M) At high lifts, 15 ft. (4.5M) and up, a foot 

 

valve is recommended. When using suction hose, make

 

sure the gasket in the female fi tting at the pump end is

 

in place and in good condition. When using pipe, coat 

 

the threads with a thread sealing compound. Suction 

 

hose must be in good condition with no leaks and lining

 

tight. A loose lining will collapse under suction and keep

 

liquid from being drawn into pump. A coarse strainer at 

 

end of suction hose is advisable if there is a possibility 

 

of pumping large, hard, unbreakable solids, such as, 

 

rocks, wood, tin cans, etc., that could be caught between

 

connecting rod and water box, causing pump damage.

4.  To lead water away, connect non-collapsible suction
 

hose to the discharge connection. Discharge hose should

 

not be smaller than suction hose and not kinked. 

 

Discharge head should never exceed 25 ft. (7.6M)

5.  On high lifts, or if pump has been idle and valves are dry,
 

pour water into the discharge opening to help seal valves

 

and speed up priming.

6.  Pump speed can be regulated with throttle control on
 

engine. from full volume, 65 strokes, to about 40 strokes 

 

for lesser volume and seepage. By regulating pump 

 

speed to suction and discharge conditions, the 

 

intermittent up and down movements of the liquid 

 

columns in the suction and discharge hoses can be 

 

timed so they will assist each other and smooth out the

 

pump operation, rather than act in opposition. Smoothest

 

operation can be determined by trying pump at several

 speeds.
7.  Drain pump in freezing weather by removing drain plugs.

SECTION D: MAINTENANCE INSTRUCTIONS

1.  Keep interior of pump and valves clean. When pumping
 

liquids containing foreign materials, fl ush out pump with

 

clear water whenever possible.

2.  Keep suction hose air tight and check for leaks and loose
 

lining, as these are major trouble sources when priming.

3.  Valves and valve weights must be straight, seat well and
 

have no cracks.

4.  The capacity of a diaphragm pump will vary greatly
 

depending on the height of the suction lift and length of

 

discharge line. A discharge line which is too small, long 

 

or high will cause:

 

A. Excessive bulging of diaphragm on down stroke.

 

B. Valves closing with loud snap.

 

C. Rough operation.

 

D. Engine overloads and slows down.

 

E. Reduced capacity.

5.  Check all bolts frequently and keep them drawn up tightly.
6.  TO CHANGE DIAPHRAGM:
 

A. Rotate the power source (manually) such that the

 

diaphragm is in the down position.

 

B. Remove four 5/8” Dia. bolts that hold the clamp ring

 

and diaphragm to the waterbox. Also remove the two 

 

5/8” nuts that hold the diaphragm to the connecting rod.

Содержание 44CDD6

Страница 1: ...ct improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 082922 Rev E Models 44CDD6 44CDG10 DISCONTINUED Parts NOT available Manual...

Страница 2: ...1 RETURNED GOODS POLICY 11 WARRANTY 12 START UP REPORT 13 14 WARRANTY REGISTRATION Other brand and product names are trademarks or registered trademarks of their respective holders Barnes is a registered trademark of Crane Pumps Systems Inc 1987 1997 1998 2002 4 06 9 06 Alteration Rights Reserved WARNING The engine exhaust from this product contains chemicals know to the State of California to cau...

Страница 3: ...commendation for maximum performance as this could cause the motor to overheat When towing pump behind a vehicle make sure hitch is properly attached always attach safety chains WARNING If Engine driven never operate in an enclosed building or area where exhaust gases can accumulate Never operate near a building where exhaust gases can seep inside Never operate in a pit or sump without making prov...

Страница 4: ...itch ENGINE 44CDD6 44CDD6 1 Make Model Hatz 1B20 w 6 1 Reduction Recoil Diesel Rating 4 6HP 3600RPM Tank Run TIme 79 Gal US 3Hr Trailer Mount 40 Gal 166Hr ENGINE 44CDG10 44CDG10 1 Make Model Briggs Stratton 205452 w 6 1 Reduction Recoil Gasoline Rating 10HP 3600RPM Tank Run TIme 1 0 Gal US 2Hr Trailer Mount 40 Gal 80Hr OPTIONAL EQUIPMENT Electric Start SECTION A PUMP SPECIFICATIONS Skid Mounted in...

Страница 5: ...e pump as close to water as possible Vertical suction lift should not exceed 25 ft 7 6M At high lifts 15 ft 4 5M and up a foot valve is recommended When using suction hose make sure the gasket in the female fitting at the pump end is in place and in good condition When using pipe coat the threads with a thread sealing compound Suction hose must be in good condition with no leaks and lining tight A ...

Страница 6: ...ooks dry Use an Exxon Ronex MP grease or equal SECTION E TROUBLE SHOOTING If your pump does not prime or operate properly check the following 1 Pump may be too high above or far from water 2 Leaks in suction hose or hose connection to pump Check if hose inner lining has loosened If loose pump suction will cause lining to collapse and block hose 3 Valves may not be seating properly due to accumulat...

Страница 7: ...7 Figure 1 ...

Страница 8: ...P1162 Waterbox 8 8 Hex Screws 5 8 x 3 HN LW 9 2 1 4 Pipe Plug 10 2 P5436 Handhole Cover 12 4 P1170 Valve Binder 13 8 A 010 037 0125 Hex Screws 3 8 x 1 1 4 14 4 P1175 Valve Weight 15 4 P1176 Valve Weight Binder 16 8 Carriage Bolt 5 16 x 1 1 4 MN LW 17 8 P5512 Stud 1 2 13 x 1 3 4 18 2 Pipe Plug 3 8 19 4 P1187 Suction Discharge Valve Rubber 20 2 P1198 Suction Valve Connection 21 4 Hex Screws 5 8 x 1 ...

Страница 9: ...7 44CDG10 48 1 Key Gib Head 1 4 x 2 49 3 P1173 LeverPin 50 1 P1850A Walking Beam Assembly with Bushings 51 1 P1851 Walking Beam Bracket 52 2 Sq Hd Set screws 3 8 x 1 1 4 53 1 P1852 Bearing Stand 54 1 P1853 120 Tooth Gear 55 1 KeyGib Head 3 8 x 3 8 x 2 1 2 56 1 P1854 Connecting Rod End 57 1 P1855 Connecting Rod Fork 58 1 Sq Hd Set screw 3 8 x 1 59 1 P1856A Crank Pin Hub with Dowel Pin 60 1 P3698 Ne...

Страница 10: ...10 Figure 3 ...

Страница 11: ... P4823 Safety Chain 81 1 P3139 Towing Pole 82 2 PM114 Light Side Marker Yellow 83 1 P5449 Lock Pin Assembly 84 1 TWS158DTSF Jack 85 1 P3140 Adjustable Leg 86 4 A 010 050 0150 Hex Screw 1 2 13 x 1 1 2 87 8 Bevel Washer 1 2 88 8 Hex Lock Nut 1 2 13 89 2 P5411 Axle Support Block 90 2 P5596 U Bolt 1 2 20 91 4 Hex Lock Nut 1 2 20 92 1 W26 32 14 Axle with Style 84 Spindles 93 1 P5593 Axle Support Tube 9...

Страница 12: ...e guarantees in the nature of performance specifications furnished in addition to the foregoing material and workmanship warranties on a product manufactured by us if any are subject to laboratory tests corrected for field performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccur...

Страница 13: ...ocation of Installation Person in Charge Phone Purchased From Crane Pumps Systems Representative Distributor Pump Model Serial No Part Number Trailer type Skid Mounted Contractor Trailer Highway Trailer Other Condition of Equipment Good Fair Poor Condition of Trailer Good Fair Poor Condition of Pump Good Fair Poor Condition of Engine Good Fair Poor Startup Checklist BEFORE Starting Engine Check Ad...

Страница 14: ...e of Company Date I Certify this report to be accurate Name of Start Up Person Employed By Date Date and Time of Start Up Present at Start Up Engineer Operator Contractor Other TO BE FILLED OUT BY FACTORY Start Up form checked by Date warranty registration mailed ...

Страница 15: ...E CITY STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Systems Inc Warranty Service Group If you have a claim under the provision of the warranty contact your local Crane Pumps Systems Inc Distributor ...

Страница 16: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE ...