11
2. Product description
2.1 Pump design
FLUID
PUMP
MOTOR
DISCHARGE CONNECTION
TYPE / TEMPERATURE
IMPELLER
SHAFT SEAL
BEARING
TYPE, POLES
INSULATION
MOTOR PROTECTOR
(BUILT-IN)
LUBRICANT
Hose coupling
Work drainage and sand carrying / 32 - 104 °F
Open
Double mechanical seal
Sealed ball bearing
Dry type submersible induction motor, 2 poles
Class F
Circle thermal protector (available only for some models)
Turbine oil VG32
Miniature protector (non-standard configuration)
2.2 Intended use
The product is intended for moving waste water, raw and clean water. Always follow the limits given in
Application limits
(page 15). If there is a question regarding the intended use of the equipment, please contact the manufacturer
representative before proceeding.
WARNING
Only X-Proof approved pumps may be used in an explosive or flammable environment.
NOTICE
Do NOT use the pump in highly corrosive liquids.
2.3 Data plate
1
15
5
10
7
8
12
14
9
11
2
3
4
6
13
Legend
No.
Pump model
9
1
Motor phase number
10
2
Voltage
11
3
Frecuency
12
4
Power
13
5
Speed
14
6
Rated current
15
7
Thermal class
8
Legend
Max capacity
Discharge bore
Max total head
Max liquid temperature
Weight
Max inmersion depth
Serial number
No.
barmesapumps.com
Содержание KTM Series
Страница 42: ......