Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs.

Troubleshooting Chart

PROBLEM

PROBABLE CAUSE

CHECK

- Threaded joints in the suction tightness.
- Gaskets for no wear.
- The mechanical seal for leaks.
- The drain plug has leaks.
- The vacuum gauge may be leaking.

2. Insufficient liquid in the 
pump casing.

- That the pump´s body is  lled with water.

3. Low operating speed.

- The motor speed (RPM).

- Impeller rotates freely.

- Internal parts are clean.

5. Mechanical defect.

- That the internal parts are not worn.

B) The pump does not prime, 
the vacuum gauge reading 
indicates higher than normal.

1. Pipe clogged suction.

- The suction line is clean.

1. The pump speed is very 
low.

- The voltage is correct.

2. Mechanical defects.

- The internal parts for wear.

- The discharge is clear of obstructions.

- That the discharge valves operate correctly.

1. suction dynamic level 
too high.

- When the pump is operating, never lacks 
water in the suction.
- For leaks in suction piping,  anges and 
gaskets.
- That there is no vortex effect at the end of 
the suction, this lack of water.
- That screws are tight at the base.
- There are no cracks in the base.
- The dynamic level is not too high
- That the pumping capacity is not too much.
- The pump is operating in the range of NPSHR
- If reducing  ow makes the noise gone, then 
the problem is in the point above; partially 
close the discharge valve.
- The bearings for wear.
- That there is oil in the deposit.
- The impeller does not have any foreign 
material.
- The pump is operating in the range.
- That the alignment is correct.

1. Low Voltage.

- The voltage is correct.
- The amperage of the plate is not exceeded.
- There is no foreign material that may force 
the impeller.
- That the motor is suitable for the pump.

2. Overload.

A) The pump does not prime, 
the vacuum gauge indicates a 
lower reading than normal.

F) The pump priming pumps 
well and satisfactorily but noisy.

E) The pump loses its priming 
during operation, vacuum 
gauge reading drops to zero.

G) Motor overload.

4. Vibration.

1. Pump base is loose.

2. Cavitation.

3. Bearings.

2. The pump is sucking air.

D) The pump priming good 
vacuum gauge reading is 
almost normal, reading the 
manometer is greater.

1. Discharge obstructed.

1. Air leak in the suction 
system.

4. Bound pump.

C) The pump priming good 
vacuum gauge reading is 
normal, the manometer 
indicates a lower pressure than 
normal.

NOTE: 

Barmesa Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other 

than at Barmesa Pumps or its authorized service centers, automatically voids warranty.

barmesapumps.com

26

Содержание IA Series

Страница 1: ...eration Maintenance Manual End Suction Centrifugal Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump IA SERIES 2 125 HP 1750 y 3500 RPM barmesapumps com Last up...

Страница 2: ...fore handling or servicing the pump or any accessory items associated with or near the pump Do not block or restrict the discharge pipe hose T h i s p u m p i s n o t i n t e n d e d f o r u s e i n s...

Страница 3: ...ynamically balanced SEAL Mechanical type 01 Ceramic stationary part carbon ring seal and exclusion in the rotatingpart Buna Nelastomerandstainlesssteelspring SHAFTSLEEVE Stainlesssteel O RINGS Buna N...

Страница 4: ...should be as close as possible to the liquid to be pumped with a minimum number of couplings adapters etc in order to reduce friction on the suction side The suction and discharge piping must be perf...

Страница 5: ...25 21 05 8 55 2 88 0 75 110 454 88 3 24 7 10 3 37 0 88 120 530 119 33 2 13 5 4 51 1 17 0 38 140 568 137 5 38 1 15 45 5 16 1 33 0 43 150 605 156 43 17 4 5 81 1 49 0 48 160 643 48 55 19 65 6 54 1 67 0 5...

Страница 6: ...3 36 STANDARD 45 ELBOW 0 38 0 54 0 61 0 77 0 92 1 15 1 53 1 83 2 29 STANDARD TEE 1 68 2 29 2 75 3 36 4 28 5 19 6 71 8 23 10 1 ANGLE GLOBE VALVE OPEN 3 97 5 49 6 71 8 23 10 7 12 2 16 8 21 3 25 9 GLOBE...

Страница 7: ...ave plugs and these must be removed to allow trapped air to escape Use pipe or hose reinforced sufficiently robust to prevent destruction due to high pressure 4Discharge pipe Due to the cost of energy...

Страница 8: ...pills out Re install the male plug using a sealant IMPORTANT Do not operate pump without priming first Operating dry will damage seal 4Pre Operation 1 Check Voltage and Phase Compare the voltage and p...

Страница 9: ...ighten the nuts until the drip decreases but does not stop 4Frame All pumps come with factory lubricated bearings It is very important to have oil in the oil tank Use oil DTE26 Change the oil every 1...

Страница 10: ...ecommended that lightly polish the area of the shaft If the shaft and it radius are perfectly polished the seal can be relatively easily installed Step 2 Install the seat assembly 1 and 2 on the insid...

Страница 11: ...Drawings 10 barmesapumps com...

Страница 12: ...Drawings 11 barmesapumps com...

Страница 13: ...HIGH PRESSURE CENTRIFUGAL PUMP MODEL IA1 GENERAL DIMENSIONS SUCTION 2 NPT THREADED DISCHARGE 1 NPT THREADED KEYWAY 0 25 x 0 125 x 3 LONG 4 HOLES 1 2 barmesapumps com Drawings 12...

Страница 14: ...Drawings 13 barmesapumps com...

Страница 15: ...Drawings 14 barmesapumps com...

Страница 16: ...5 52 12 IA2 H 60 2 60 3600 3 364JM 28 11 25 IA2 H 75 2 75 3600 3 365JM 29 12 25 IA2 H 100 2 100 3600 3 405JM 32 13 75 5 75 16 10 17 25 0 81 5 75 12 5 0 66 16 5 14 9 5 8 12 0 66 HIGH PRESSURE CENTRIFUG...

Страница 17: ...0 2 30 3525 3 286JM 11 IA3 40 2 40 3530 3 324JM 10 5 IA3 50 2 50 3530 3 326JM 12 IA3H 30 2 30 3525 3 286JM 7 11 75 11 11 4 75 20 5 0 53 IA3H 40 2 40 3530 3 324JM 10 5 IA3H 50 2 50 3530 3 326JM 12 IA3H...

Страница 18: ...MODEL HP RPM PHASE FRAME A B C D E F G IA4 40 2 40 3530 3 324TSC 24 10 5 IA4 50 2 50 3530 3 326TSC 25 5 12 IA4 60 2 60 3565 3 364TSC 28 11 25 IA4 75 2 75 3555 3 365TSC 29 12 25 IA4 100 2 100 3560 3 4...

Страница 19: ...25 10 4 25 10 6 25 9 9 IA4BJH 25 4 25 1760 3 284JM 22 62 9 5 IA4BJH 30 4 30 1760 3 286JM 24 56 11 IA4BJH 40 4 40 1765 3 324JM 25 31 10 5 IA4BJH 50 4 50 1765 3 326JM 25 31 12 IA4BJH 60 4 60 1765 3 364...

Страница 20: ...IMPELLER IA1 5 2 6 81 03140031B IMPELLER IA1 2 4 IA1 7 5 2 7 50 03140031C 5 1 SHAFT SLEEVE 30400808 6 1 SLINGER 92010014 7 1 MECHANICAL SEAL 31030131 8 1 O RING 92010033 9 1 IMPELLER S SCREW 91010345C...

Страница 21: ...10 1 11 1 12 1 ITEM QTY DESCRIPTION PART ELECTRIC MOTOR 200 230 460 ODP 3 HP 1740 RPM 3 PH FRAME 182T JM 15 HP 3530 RPM 3 PH FRAME 254T JM 20 HP 3525 RPM 3 PH FRAME 256T JM 25 HP 3530 RPM 3 PH FRAME 2...

Страница 22: ...FOR 10 15 HP 3500 RPM 03010018 INTERMEDIATE COUPLING FOR 20 HP 3525 RPM 03010051 INTERMEDIATE COUPLING FOR 25 30 HP 3525 RPM 03010020 3 1 VOLUTE CASE 03090041 IMPELLER IA2 FOR 3 HP 9 00 SHAFT 7 8 031...

Страница 23: ...P 30400418 IMPELLER WASHER FOR 15 TO 50 HP 30400416 SHAFT KEY FOR 3 HP TO 7 5 HP 30400631 SHAFT KEY FOR 15 TO 50 HP 30400633 13 8 STUD 3 8 16X 1 50 91010303 14 8 HEX NUT 3 8 91010413 15 8 LOCK WASHER...

Страница 24: ...MPELLER IA1 XH 3 4 9 19 IMPELLER IA1 XH 5 4 9 19 5 1 SHAFT SLEEVE FOR 3 TO 25 HP 30400829 6 1 SLINGER FOR 3 TO 25 HP 92010016 7 1 MECH SEAL FOR 3 TO 25 HP 31030133 8 1 O RING 92010033 9 1 IMPELLER S S...

Страница 25: ...TYPICAL EXPLODED VIEW CENTRIFUGAL PUMP MODEL IA2EXH U barmesapumps com 21 MECH SEAL ROTATING PART 21 MECH SEAL STATIONARY PART FIRST HEAT THE SLEEVE AND PLACE IT ON THE SHAFT LETTING IT COOL ALREADY I...

Страница 26: ...Steel 20 1 Inner bearing 31020017 Steel 21 1 Mechanical sealT21 de 1 31030160 Carbon Ceramic 22 1 Retainer CR 19220 31150007 Steel Viton 23 8 Cap screw 1 2 x 1 91010309 Carbon Steel 24 8 Nut 1 2 91010...

Страница 27: ...pacity is not too much The pump is operating in the range of NPSHR If reducing ow makes the noise gone then the problem is in the point above partially close the discharge valve The bearings for wear...

Страница 28: ......

Отзывы: