Before installation, read the following 

instructions  carefully.  Failure  to 
follow 

instruction 

and 

safety 

information  could  cause  serious 

bodily  injury,  death  and/or  property 

damage.  Each  Barmesa  product  is 

carefully  inspected  to  insure  proper 
performance. Closely following these 
instructions  will  eliminate  potential 

operating  problems,  assuring  years 
of trouble-free service. 

01

General Safety Information

IMPORTANT! - Barmesa Pumps is not 
responsible  for  losses,  injury  or 
death  resulting  from  failure  to 
observe  these  safety  precautions, 
misuse,  abuse  or  misapplication  of 
pumps or equipment.

Installation,  wiring,  and 

junc tion  connec tions  must  be  in 
accordance  with  the  National  Electric 
Code  and  all  applicable  state  and  local 
codes. Requirements may vary depending 
on usage and location.

WARNING

I n s t a l l a t i o n   a n d 

servicing  is  to  be  conducted  by 

qualified personnel only.

WARNING

D o   n o t

  u s e   t h e s e 

pumps  in  water  over  160º  F. 

Do  not

 

exceed manufacturers recommended 
maximum performance, as this could 
cause the motor to overheat.

WARNING

C a r e f u l l y   r e a d 

instruction  manuals  supplied  with 

motor or engine before operating or 

servicing.

WARNING

A L L   R E T U R N E D 
P R O D U C T S   M U S T   B E 

CLEANED,  SANITIZED,  OR

DECONTAMINATED  PRIOR  TO 
SHIPMENT, TO INSURE EMPLOYEES 
WILL NOT BE EXPOSED TO HEALTH 

HAZARDS  IN  HANDLING  SAID 
MATERIAL. ALL APPLICABLE LAWS 
AND REGULATIONS SHALL APPLY.

Keep  clear  of  suction  and 

discharge  openings.  Do  not 

insert  fingers  in  pump  with

power  connected;  the  impeller  can 
cause serious injury.

Always  wear  eye  protection 

when working on pumps. Do 
not wear loose clothing that

may  become  entangled  in  moving 

parts.

Pumps  build  up  heat 

and  pressure  during 

operation.  Allow  time 

fo r   p u m p s   t o   c o o l

DANGER

before  handling  or  servicing  the 

pump  or  any  accessor y  items 
associated with or near the pump.

T h i s   p u m p   i s   n o t 

i n t e n d e d   f o r   u s e   i n 
swimming  pools  or  water 
installations  where  there  is

DANGER

human contact with pumped fluid.

Risk of electric shock. To 

reduce risk of electric shock, 

always  disconnect  pump 

from  power  source  before

DANGER

handling any aspect of the pumping 
system.

 Lock out power and tag.

These pumps are not to 

be  installed  in  locations 
classified  as  hazardous  in 

accordance with the National

Electric Code, ANSI/NFPA 70.

DANGER

WARNING

 “Danger” indicates an 

imminently  hazardous  situation 

which, if not avoided, WILL result in 
death or serious injury.

“Warning”  indicates 

an  imminenty  hazardous  situation 
which, if not avoided, MAY result in 
death or serious injury.

“Caution”  indicates  a 

potentially  hazardous  situation 
which, if not avoided, MAY result in 

minor or moderate injury.

DANGER

CAUTION

Operation  against  a 
closed  discharge  valve 

will  cause  premature 
bearing and seal failure.

DANGER

Heat build up on self-priming and end 

suction pumps may cause dangerous 
pressures. A high temperature switch 

o r   p r e s s u r e   r e l i e f   v a l v e   i s 
recommended to be installed in pump 

case.

Pumps  constructed 

w i t h   o r   f i t t e d   w i t h 

bronze/brass  may  contain 

lead  levels  higher  than

considered  safe  for  potable  water 
systems.  Lead  is  known  to  cause 

cancer  and  birth  defects  or  other 

r e p r o d u c t i v e   h a r m .   V a r i o u s 
g o v e r n m e n t   a g e n c i e s   h a v e 
determined that leaded copper alloys 

should not be used in potable water 
applications.

WARNING

IMPORTANT!  -  Prior  to  installation, 
record  Model  Number,  Serial,  Amps, 

Voltage,  Phase  and  HP  from  pump 
name  plate  for  the  future  reference. 
Also  record  the  Voltage  and  Current 
Readings at Startup:

Model Number: ____________________

Serial: ____________________

Amps:_______  Voltage:_______

Phase:_______  HP:_______

barmesapumps.com

Содержание BSP-CCE Series

Страница 1: ...ation Operation Maintenance Manual Self Priming Close Coupled Pumps BSP CCE 1 5 2 3 5 7 5 10 15 HP 3500 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapumps com ...

Страница 2: ...r pumps to cool DANGER before handling or servicing the pump or any accessory items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To reduce risk of electric shock always disconnect pump from power source before DANGER handling any aspect of the pumpin...

Страница 3: ...sstainlesssteel HARDWARE Steel stainlesssteel SQUARERINGS Buna N PAINT Airdryenamel waterbased SEAL Mechanical selflubrication Ceramicstationarypart carbonringsealandexclusion intherotatingpart Buna Nelastomerandstainlesssteelspring CHECKVALVE Flap neoprene Steel MOTOR Open Drip Proof or TEFC C face footed squirrel cage induction class B or F insulation Singlephase 115 230volts 60Hz 3450RPM Threep...

Страница 4: ...112 BSP4CCE3 BF 2 3 230 460 ODP 3450 6 4 5 4 2 7 18 41 92 BSP4CCE3 TBF 2 3 230 460 TEFC 3450 7 0 5 4 2 7 18 43 98 BSP4CCE1 BF 2 1 115 230 ODP 3450 26 13 17 93 101 BSP4CCE1 TBF 2 1 115 230 TEFC 3450 23 11 5 19 31 112 BSP5CCE3 3 3 230 460 ODP 3450 8 5 8 4 18 43 94 BSP5CCE3 T 3 3 230 460 TEFC 3450 8 1 7 6 3 8 18 43 97 BSP5CCE1 3 1 208 230 ODP 3450 29 14 5 18 81 105 BSP5CCE1 T 3 1 115 230 TEFC 3450 26...

Страница 5: ...68 BSP10CCE3 TBF 5 3 230 460 TEFC 3450 12 6 11 6 5 8 22 81 168 BSP10CCE1 BF 5 1 208 230 ODP 3450 24 23 20 57 178 BSP10CCE1 TBF 5 1 230 TEFC 3450 19 5 23 63 168 T totally enclosed BF bronze fitted TB totally enclosed bronze fitted Overall length of unit and amps is subject to the motor manufacture 6 76 6 76 6 76 0 18 0 18 0 18 12 09 12 09 12 09 6 16 6 16 6 16 5 68 5 68 5 68 5 44 5 44 5 44 8x Ø0 3 8...

Страница 6: ...BSP15CCE3 7 5 3 230 460 ODP 3450 18 8 17 4 8 7 23 22 248 BSP15CCE3 T 7 5 3 230 460 TEFC 3450 18 5 17 4 8 7 26 28 251 BSP15CCE3 BF 7 5 3 230 460 ODP 3450 18 8 17 4 8 7 23 22 248 BSP15CCE3 TBF 7 5 3 230 460 TEFC 3450 18 5 17 4 8 7 26 28 251 1 1 1 24 4 24 4 24 4 11 4 11 4 11 4 12 12 12 6 4 6 4 6 4 7 6 7 6 7 6 15 4 15 4 15 4 5 2 5 2 5 2 11 1 11 1 11 1 A A A 4x Ø0 5 4x Ø0 5 4x Ø0 5 0 7 0 7 0 7 13 6 13 ...

Страница 7: ...0 ODP 3450 25 2 24 12 24 79 294 BSP20CCE3 TBF 10 3 230 460 TEFC 3450 25 23 11 5 26 36 301 T totally enclosed BF bronze fitted TB totally enclosed bronze fitted Overall length of unit and amps is subject to the motor manufacture 1 1 1 25 3 25 3 25 3 12 3 12 3 12 3 12 12 12 7 7 7 0 6 0 6 0 6 8 2 8 2 8 2 15 9 15 9 15 9 5 2 5 2 5 2 11 1 11 1 11 1 A A A 4x Ø0 5 4x Ø0 5 4x Ø0 5 0 6 0 6 0 6 13 8 13 8 13 ...

Страница 8: ...No HP PHASE VOLTS ENCLOSURE RPM Nominal MAX AMPS A inches WEIGHT pounds BSP25CCE3 15 3 230 460 ODP 3450 44 40 20 24 79 322 BSP25CCE3 T 15 3 230 460 TEFC 3450 38 35 17 5 27 49 341 BSP25CCE3 BF 15 3 230 460 ODP 3450 44 40 20 24 79 322 BSP25CCE3 TBF 15 3 230 460 TEFC 3450 38 35 17 5 27 49 341 T totally enclosed BF bronze fitted TB totally enclosed bronze fitted Overall length of unit and amps is subj...

Страница 9: ...incorrect interchange any two incoming wire leads Rotation is clockwise when looking from the motor end Suction CAUTION Pump should not be operated without a suction strainer to prevent foreign matter from being drawn into impeller The strainer should be cleaned regularly Priming Remove pipe plug in top of body and fill the pump body completely with solids free liquid In freezing weather prime pum...

Страница 10: ...09 Repair Parts 4 BSP3 4 5CCE barmesapumps com ...

Страница 11: ...CAST IRON 03140229 IMPELLER 3CCE BRONZE SAE 40 03140222 IMPELLER 4CCE CAST IRON 03140230 IMPELLER 4CCE BRONZE SAE 40 03140223 IMPELLER 5CCE CAST IRON 03140231 IMPELLER 5CCE BRONZE SAE 40 03140224 13 1 HEX NUT 7 16 20UNF SS 91010434 VOLUTE 3 4 5CCE CASTIRON 03120038 VOLUTE 3 4 5CCE BRONZE SAE 40 03120034 16 2 ROLL PIN 17715 Ø x 1 91010181 17 1 GASKETVOLUTE 3 4 5CCE BUNA N 92010091 18 1 BODY 3 4 5CC...

Страница 12: ...11 Repair Parts barmesapumps com 4 BSP10CCE ...

Страница 13: ...4 2 SHAKEPROOF WASHER 1 2 SS 91010081 VOLUTE 10CCE CAST IRON 03120039 VOLUTE 10CCE BRONZE SAE 40 03120035 16 2 ROLL PIN 17715 Ø x 1 91010181 17 1 GASKETVOLUTE 10CCE BUNA N 92010091B 18 1 BODY 10CCE CAST IRON 03090097 19 3 STUD 3 8 16 x 2 91010374 20 7 LOCK WASHER 3 8 91010012 21 3 HEX NUT 3 8 91010413 22 CHECK VALVE ASSEMBLY 22A 1 WEIGHT Ø1 56 03080001 22B 1 WEIGHT Ø2 03080002 22C 1 GASKET 2 92010...

Страница 14: ...13 Repair Parts barmesapumps com 4 BSP15 20 25CCE ...

Страница 15: ...R 25CCE BRONZE SAE 40 03140228 13 1 HEX HEAD SCREW 1 2 20UNF x 1 SS 91010349B 14 2 SHAKEPROOF WASHER 1 2 SS 91010081 VOLUTE 15 20CCE CAST IRON 03120040 VOLUTE 15 20CCE BRONZE 03120036 VOLUTE 25CCE CAST IRON 03120041 VOLUTE 25CCE BRONZE 03120037 16 2 ROLL PIN 17715 Ø x 1 91010181 17 1 GASKETVOLUTE 15 20 25CCE BUNA N 92010122 18 1 BODY 15 20 25CCE CAST IRON 03090098 19 5 STUD 1 2 13 x 2 91010310 20 ...

Страница 16: ...avitationpresent 5 Pipingnotsupportedtorelieveanystrainon pumpassembly Pump runs but no fluid 1 Airleakinsuctionpiping 2 Pumplocatedtoofarfromfluidsource 3 Gatevalveclosed 4 Cloggedstrainer 5 Fouledfoot valve 6 Dischargeheighttoogreat 7 Fouledimpeller 8 Faultymechanicalseal Pump leaks at shaft 1 Wornmechanicalseal 2 Sealnotinstalledproperly 1 Fillpumpbodywithwater 2 Shortensuctionhead 3 Lowersucti...