background image

09

Troubleshooting Chart

Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs.

Symptom

Possible Cause(s)

Corrective Action

Pump will not run

1.   Poor electrical connection, blown fuse, tripped 

  breaker or other interruption of power; 

  improper power supply
2.   Motor or switch inoperative (go to manual 
  operation)
2a. Float movement restricted
2b. Switch will not activate pump or is defective
2c. Defective motor
3.   Insuffi cient liquid level

1.  Check all electrical connections for security. 
  Have electrician measure current in motor leads, 
  if current is within ± 20% of locked rotor Amps, 
  impeller is probably locked. If current is 0, 
  overload may be tripped. Remove power, allow 
  pump to cool, then re-check current.
2a. Reposition pump or clean basin as required to 
  provide adaquate clearance for float
2b. Disconnect level control. Set ohmmeter for a 
  low rang, such as 100 ohms full scale and 
  connect to level control leads. Actuate level 
  control manually and check to see that 
  ohmmeter shows zero ohms for closed switch 
  and full scale for open switch. (Float Switch)
2c. Check winding insulation (Megger Test) and 
  winding resistance. If check is outside of range, 
  dry and re-check. If still defective, replace per 
  service instructions.
3.  Make sure liquid level is above the pump
4.  Re-check all sizing calculations to determine 
  proper pump size.
5.  Check discharge line for restrictions, including 
  ice if line passes through or into cold areas.
6.  Remove and examine check valve for proper 
  installation and freedom of operation
7.  Open valve
8.  Check impeller for freedom of operation, 
  security and condition. Clean impeller cavity 
  and inlet of any obstruction
9.  Loosen union slightly to allow trapped air to 

 escape. Verify that turn-off level of switch is set 

  so that the suction is always flooded. Clean vent
  hole
10. Check rotation. If power supply is three phase, 
  reverse any two of three power supply leads to 
  ensure proper impeller rotation
11. Repair fixtures as required to eliminate leakage
12. Check pump temperature limits and fluid
  temperature
13. Replace portion of discharge pipe with flexible
  connector or tighten existing piping.
14. Turn to automatic position
15. Check for leaks around basin inlet and outlets

Pump will not turn off 

2a. Float movement restricted
2b. Switch will not activate pump or is defective
4.   Excessive inflow or pump not properly sized for 

application

9.   Pump may be air locked causing pump not to flow
14. H-O-A switch on panel is in "HAND" position

Pump hums but doesn’t run

1.  Incorrect low voltage
8.  Impeller jammed or loose on shaft, or inlet 
  plugged

Pump delivers insufficient capacity

1.  Incorrect low voltage
4.   Excessive inflow or pump not properly sized for
  application
5.  Discharge restricted
6.  Check valve partially closed or installed backwards
7.   Shut-off valve closed
8.  Impeller jammed or loose on shaft, or inlet 
  plugged
9.  Pump may be air locked causing pump not to flow
10. Piping fixtures leaking or discharge before the 
  nozzle

Pump cycles too frequently or runs periodically 

when f ixtures are not in use

6.  Check valve partially closed or installed backwards
11. Fixtures are leaking
15. Ground water entering basin

Pump shuts of f and turns on independent of

switch, (trips thermal overload protector). 

CAUTION!

Pump may start unexpectedly. 

Disconnect power supply.

1.  Incorrect low voltage
4.   Excessive inflow or pump not properly sized for
  application
8.  Impeller jammed or loose on shaft, or inlet 
  plugged
12. Excessive water temperature (internal 
  protection only)

Pump operates noisily or vibrates excessively

2c. Worn bearings, motor shaft bent
5.  Debris in impeller cavity or broken impeller
10. Pump running backwards
13. Piping attachments to building structure too 
  loose or rigid

NOTE: 

Barmesa Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other 

than at Barmesa Pumps or its authorized service centers, automatically voids warranty.

barmesapumps.com

Содержание BPSTEP1022

Страница 1: ...Installation Operation Maintenance Manual Submersible Effluent Pumps BPSTEP 0 5 1 HP 3450 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapumps com...

Страница 2: ...atedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To reduce r...

Страница 3: ...MA 48class30 SEALPLATE CastironASTMA 48class30 IMPELLER Singlevaneenclosed Polypropylenewithstainlesssteelinsert SHAFT Stainlesssteel O RINGS SquareshapedBuna N PAINT Airdryenamel waterbased SEAL Outb...

Страница 4: ...l NOT be installed in locations classified as hazardous in accordance with the National Electrical Code NEC ANSI NFPA 70 or Canadian Electric Code CEC The pump should never be installed in a trench di...

Страница 5: ...t or the sensor will not work properly TEMPERATURE SENSOR ELECTRICAL RATINGS Volts Continuous Amperes Inrush Amperes 110 120 3 00 30 0 220 240 1 50 15 0 Wire Size If longer power cable is required c a...

Страница 6: ...after five minutes the pressure is still holding constant and no bubbles oil seepage is observed slowly bleed the pressure and remove the gauge assembly Replace oil Leek must be located and repaired...

Страница 7: ...ring replace if cut or damaged Disconnect capacitor leads from capacitor Remove motor bolts lift cover body and stator assembly from seal plate Remove snap ring to remove rotor assembly Remove bearing...

Страница 8: ...07 Repair Parts BPSTEP For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesapumps com...

Страница 9: ...plate 1 HT200 16 Impeller 117 3 1 Polypropylene 17 Casing 1 HT200 18 U shpe ring 31 5 x 44 3 x 6 5 1 NBR40 19 Casing sealing washer 1 Rubber 20 Hex socket cap screws 1 4 20UNCx28 2 304 21 V shape ring...

Страница 10: ...e any two of three power supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of dis...

Страница 11: ......

Страница 12: ......

Отзывы: