Recommendations and Warnings

Bottom of Feet

10"

Recommended
Submergence Level

Minimum
Submergence Level

Figure 1

4

Receiving inspection

Upon  receiving  the  pump,  it  should 
be  inspected  for  damage  or 
shortages.  If  damage  has  occurred, 
file  a  claim  immediately  with  the 
company that  delivered the pump. If 
the  manual  is  removed  from  the 
packaging, do not lose or misplace.

4

Storage

Any  product  that  is  stored  for  a 
period  longer  than  six  (6)  months 
from the date of purchase should be 
bench  tested  prior  to  installation.  A 
bench  test  consists  of,  checking  the 
impeller  to  assure  it  is  free  turning 
and  a  run  test  to  assure  the  motor 
(and  switch  if  provided)  operate 
properly.

4

Controls

Manual  models  require  a  separate 
approved  pump  control  device  or 
panel  for  automatic  operation.  Be 
sure the electrical specification of the 

control  selected  properly  match  the 

electrical specifications of the pump.

4

Submergence

The  pump  should  always  be 
operated 

in 

the 

submerged 

condition. The minimum sump liquid 
level should never be less than above 
the pump’s volute (See Figure 1).

4

Installation

These  pumps  are  recommended  for 
use  in  a  sump,  basin  or  lift  station. 
The  sump,  basin  or  lift  station  shall 
be  sealed  and  vented  in  accordance 
with  local  plumbing  codes. 

This 

pump  is  designed  to  pump 
sewage,  effluent  or  wastewater, 
non-explosive  and  non-corrosive 
liquids  and  shall  NOT  be  installed 
in locations classified as hazardous 
in  accordance  with  the  National 
Electrical  Code  (NEC)  ANSI/NFPA 
70 or Canadian Electric Code (CEC).

 

The  pump  should  never  be  installed 
in  a  trench,  ditch,  or  hole  with  a  dirt 
bottom.  The  legs  will  sink  into  the 
dirt  and  the  suction  will  become 
plugged.

The  installation  should  be  at  a 
sufficient  depth  to  ensure  that  all 
plumbing  is  below  the  frost  line.  If 
this is not feasible, remove the check 
valve  and  size  the  basin  to 
accommodate 

the 

additional 

backflow volume.

Pumps  are  most  commonly  installed 
in  simplex  or  duplex  stations  or 
basins  with  a  slide  rail  system 
(Barmesa  SRC),  which  allows  the 
pump(s)  to  be  installed  or  removed 
without requiring personnel to enter 
the  station,  or  resting  on  the  basin 
floor.

4

Discharge Piping

Discharge  piping  should  be  as  short 
as possible and sized no smaller than 
the  pump  discharge. 

Do  not  reduce 

the  discharge  pipe  size  below  that 
which  is  provided  on  the  pump.

 

Both  a  check  valve  and  a  shut-off 

valve  are  recommended  for  each 

pump.  The  check  valve  is  used  to 
prevent backflow  into the sump. The 
shut-off  valve  is  used  to  manually 
stop  system  low  during  pump 
servicing.

Overload Protection:
Single Phase

 - The stator in-winding 

overload protector used is referred to 
as an inherent overheating protector 
and operates on the combined effect 
of  temperature  and  current.  This 
means  that  the  overload  protector 
will trip out and shut the pump off if 
the windings become too hot, or the 
load  current  passing  through  them 
becomes too high. 

4

Liquid Level Controls

The  level  control(s)  should  be 
mounted on  the  discharge  piping,  a 

 

cable  rack or  l

 

f oat  pole.  The  level 

control  should  have  adequate 

clearance so it cannot hang up in it’s 

 

 

swing  and  that  the  pump

is 

 

completely  submerged  when  the 
level  control  is  in  the  "Off "  mode.  By 
adjusting the cord tether the control 
level  can  be  changed.  One  cycle  of 
operation  should  be  observed,  so 
that  any potential  problems  can  be 

 

corrected.

4

Electrical Connections

Power cable:

The  power  cable  mounted  to  the 
pump must  not  be  modi ied  in  any 

 

f

way  except for  shortening  to  a 

 

speci ic  application.

Any  splice 

f

 

between  the  pump  and  the control 

 

panel  must  be  made  in accordance 

 

with  the  electric  codes.  It  is 
recommended that a junction box, if 
used, be  mounted  outside  the  sump 

 

or  be  of at  a  minimum  Nema  4 

 

construction if located within the wet 

 

well. 

DO  NOT  USE  THE  POWER 

CABLE TO LIFT PUMP.

It  is  recommended  that  the  level 
control l

  f oat  should  be  set  to  insure 

that  the  liquid  in  the  sump  never 

drops  below  the  top  of the  motor 

 

housing  or  a  minimum  level  of 10 

 

inches above the basin  l

f oor.

Always  rely  upon  a  C

ed 

ertifi

Electrician for installation.

barmesapumps.com

Содержание 6BSE12036LDS

Страница 1: ...s Handling Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump 6BSE LDS 6BSE HLDS 9 12 18 24 30 HP 1150 RPM 18 24 30 36 48 60 HP 1750 RPM 6BSE HLDS 30 60 HP 6BSE LDS 9 30 HP 18 60 HP Last update 08 07 2020 barmesapumps com ...

Страница 2: ...ory items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To reduce risk of electric shock always disconnect pump from power source before DANGER handling any aspect of the pumping system Lockoutpowerandtag Do not lift carry or hang pump by the electric...

Страница 3: ...seal sliderailcoupling SRC 6 The moisture cord and or temperature cord is size 18 5 type SO Ø0 485 for all models 6BSE18034LDS 18 230 3 1750 50 6 232 F 2 3 G 1 34 891 6BSE18044LDS 18 460 3 1750 25 3 116 F 2 3 G 1 34 891 6BSE24034LDS 24 230 3 1750 62 8 290 E 2 3 G 1 34 928 6BSE24044LDS 24 460 3 1750 31 4 145 E 2 3 G 1 34 928 6BSE30034LDS 30 230 3 1750 75 8 364 E 2 3 G 1 34 985 6BSE30044LDS 30 460 3...

Страница 4: ... SIZE CORD TYPE CORD O D WEIGHT pounds 6BSE30034HLDS 30 230 3 1750 76 364 F 2 3 G 1 34 957 6BSE30044HLDS 30 460 3 1750 38 182 F 2 3 G 1 34 957 6BSE36034HLDS 36 230 3 1750 90 434 E 2 3 G 1 34 963 6BSE36044HLDS 36 460 3 1750 45 217 F 2 3 G 1 34 963 6BSE48044HLDS 48 460 3 1750 65 290 E 2 3 G 1 34 974 6BSE60044HLDS 60 460 3 1750 78 363 E 2 3 G 1 34 1005 46BSE HLDS 46BSE LDS barmesapumps com ...

Страница 5: ...uplex stations or basins with a slide rail system Barmesa SRC which allows the pump s to be installed or removed without requiring personnel to enter the station or resting on the basin floor 4Discharge Piping Discharge piping should be as short as possible and sized no smaller than the pump discharge Do not reduce the discharge pipe size below that which is provided on the pump Both a check valve...

Страница 6: ... phase information stamped on the pump name plate 2 Check Pump Rotation Improper motor rotation can result in poor pump performance and can damage the motor and or pump Check rotation on three phase units by momentarily applying power and observe the kickback Kickback should always be in a counter clockwise direction as viewed from motor end or opposite to impeller rotation Impeller rotation is co...

Страница 7: ... box 4 to motor housing 3 Apply thread locking compound to cap screws 6 and place into holes and torque to 15 ft lbs Oil Replacement Seal Chamber Refill chamber completely full with new cooling oil or reuse the uncontaminated oil Figure 2 a Inspect motor chamber for oil level and contamination b Inspect impeller and body for excessive build up or clogging c Inspect motor bearings and shaft seal fo...

Страница 8: ...nd bell from motor 1 Remove wave washer Remove upper bearing 2 with a wheel puller if damaged or worn Vertically lift stator 1 from rotor shaft Inspect windings for shorts and resistance Test the temperature sensors by checking for continuity between the black and white wires If defective contact factory or motor service station Pull motor rotor shaft with bearing 1 3 from bearing housing 1 Remove...

Страница 9: ...r cap screws 25 Conduit Box Assembly Check power 38 and control cables 39 for crackes or damage and replace complete conduit box 4 if required See Figure 4 Bring motor wires through opening in top of motor housing 3 check sleeving and replace if damaged Position square ring 5 in conduit box 4 and reconnect leads using connectors and insulators See Figures 5 for wiring schematics Refill with coolin...

Страница 10: ... should be approximately 0 012 inch 09 Service G T1 T7 T2 T8 T3 T9 T4 T5 T6 G L1 L2 L3 GREEN BLACK RED WHITE MOTOR LEADS THREE PHASE 230V AC Cable Motor Lead Number Green Green Black 1 and 7 Red 2 and 8 White 3 and 9 4 5 and 6 together Figure 5 T2 T3 T4 T7 T5 T8 T6 T9 G L2 L3 RED WHITE MOTOR LEADS T1 L1 BLACK G G GREEN THREE PHASE 460V AC Cable Motor Lead Number Green Green Black 1 Red 2 White 3 4...

Страница 11: ...Figure 6 10 Repair Parts VOLUTE FOR 6BSE HLDS barmesapumps com For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List ...

Страница 12: ...11 Parts List 46BSE LDS barmesapumps com 30400423 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List ...

Страница 13: ...12 Parts List 46BSE HLDS barmesapumps com 30400423 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List ...

Страница 14: ... supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible connector or tighten existing piping 14 Turn to automatic position 15 Check for leaks around basin inlet and outlets Pump will not turn off 2a Float movement restricted 2b Switch will not activate p...

Страница 15: ......

Отзывы: