background image

Before installation, read the following 

instructions  carefully.  Failure  to 
follow 

instruction 

and 

safety 

information  could  cause  serious 

bodily  injury,  death  and/or  property 

damage.  Each  Barmesa  product  is 

carefully  inspected  to  insure  proper 
performance. Closely following these 
instructions  will  eliminate  potential 

operating  problems,  assuring  years 
of trouble-free service. 

01

General Safety Information

IMPORTANT! - Barmesa Pumps is not 
responsible  for  losses,  injury  or 
death  resulting  from  failure  to 
observe  these  safety  precautions, 

misuse,  abuse  or  misapplication  of 
pumps or equipment.

Installation,  wiring,  and 

junc tion  connec tions  must  be  in 
accordance  with  the  National  Electric 
Code  and  all  applicable  state  and  local 
codes. Requirements may vary depending 
on usage and location.

WARNING

I n s t a l l a t i o n   a n d 

servicing  is  to  be  conducted  by 

qualified personnel only.

WARNING

D o   n o t

  u s e   t h e s e 

pumps  in  water  over  104  °F. 

Do  not

 

exceed  manufactures  recommended 
maximum performance, as this could 

cause the motor to overheat.

WARNING

Ground  Fault  Circuit 

Interrupter  (GFCI)  to  be  used  with 

plug-in type power cord.

WARNING

A L L   R E T U R N E D 
P R O D U C T S   M U S T   B E 
CLEANED,  SANITIZED,  OR

DECONTAMINATED  PRIOR  TO 

SHIPMENT, TO INSURE EMPLOYEES 
WILL NOT BE EXPOSED TO HEALTH 
HAZARDS  IN  HANDLING  SAID 

MATERIAL. ALL APPLICABLE LAWS 
AND REGULATIONS SHALL APPLY.

Keep  clear  of  suction  and 

discharge  openings.  Do  not 

insert  fingers  in  pump  with

power connected; the rotating cutter 

and/or  impeller  can  cause  serious 

injuty.

Always  wear  eye  protection 

when working on pumps. Do 

not wear loose clothing that

may  become  entangled  in  moving 

parts.

Pumps  build  up  heat 
and  pressure  during 
operation.  Allow  time 

fo r   p u m p s   t o   c o o l

DANGER

before  handling  or  servicing  the 
pump  or  any  accessor y  items 

associated with or near the pump.

Risk of electric shock. To 

reduce risk of electric shock, 

always  disconnect  pump 

from  power  source  before

DANGER

handling any aspect of the pumping 
system.

 Lock out power & tag.

Do  not

  lift,  carry  or 

hang pump by the electrical 

c a b l e s.   D a m a g e   to   t h e 

electrical  cables  can  cause

DANGER

shock, burns or death. 

Never

 handle 

connected  power  cords  with  wet 

hands. Use appropriate lifting device.

Failure  to  permanently 

ground the pump, motor and 

controls  before  connecting 

to  power  can  cause  shock,

DANGER

burns or death.

The  Uniform  Plumbing 

Code  (UPC)  states  that  sewage 

systems shall have an audio and visual 

alarm that signals a malfunction of the 

systems,  that  are  required  to  reduce 
the potencial for property damage.

WARNING

IMPORTANT!  -  Prior  to  installation, 
record  Model  Number,  Serial,  Amps, 

Voltage,  Phase  and  HP  from  pump 
name  plate  for  the  future  reference. 

Also  record  the  Voltage  and  Current 

Readings at Startup:

WARNING

 Indicates  an  immi-

nently hazardous situation which, if 

not avoided, WILL result in death or 

serious injury.

Indicates  an  immi-

nenty hazardous situation which, if 
not avoided, MAY result in death or 
serious injury.

Indicates a potentially 

hazardous  situation  which,  if  not 
avoided,  MAY  result  in  minor  or 
moderate injury.

DANGER

CAUTION

T h i s   p u m p   i s   n o t 

i n t e n d e d   f o r   u s e   i n 
swimming  pools  or  water 

installations  where  there  is

DANGER

human contact with pumped fluid.

These pumps are not to 

be  installed  in  locations 

classified  as  hazardous  in 
accordance with the National

Electric Code, ANSI/NFPA 70.

DANGER

barmesapumps.com

Model  Number:_____________________

Serial:_____________________________

Amps:___________    Volts:____________

Phase:____________  HP:_____________

Содержание 2AHS051

Страница 1: ...Installation Operation Maintenance Manual Submersible Dewatering Pumps 2AHS 0 5 1 2 HP 3500 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapumps com...

Страница 2: ...Pumps build up heat and pressure during operation Allow time for pumps to cool DANGER before handling or servicing the pump or any accessory items associatedwithornearthepump Riskofelectric shock To r...

Страница 3: ...onFC 200 MOTORHOUSING AluminumalloyADC12 OILCHAMBER CastironFC 200 IMPELLER 8vane semi openVortex Hytrel thermoplasticelastomer SHAFT 410seriesstainlesssteel HARDWARE 304seriesstainlesssteel O RINGS N...

Страница 4: ...he tank support the piping where appropriate Install piping so that air will not be entrapped If piping must be installed in such a way that air pockets are unavoidable install an air release valve wh...

Страница 5: ...r Main Coil Black Brown White Blue Green Yellow Green Frame Grounding Ground Starting Coil Single phase Black Black White Blue Red Brown R S T U V W U2 V2 W2 Overload Protector Green Green Yellow Grou...

Страница 6: ...side with filler plug on top Inject suitable amount turbine oil no 32 ISO VG 32 Inspections at 3 5 year intervals Conduct an overhaul of the pump These intervals will preclude the possibility of futu...

Страница 7: ...06 Repair Parts Figure 5 For repair part please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesapumps com 2AHS 0 5 HP...

Страница 8: ...W SUS 304 26 T ADAPTER OPTIONAL 19 4 SCREW STEEL 29 INSULATING PAPER 19 5 SCREW SUS 304 34 CORRUGATED SPRING STEEL barmesapumps com 2AHS 0 5 HP ITEM NAME MATERIAL PHOTO ITEM NAME MATERIAL PHOTO 1 CABL...

Страница 9: ...Figure 6 2AHS 1 HP For repair part please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List 08 Repair Parts barmesapumps com...

Страница 10: ...W 19 3 SCREW SUS 304 26 T ADAPTER OPTIONAL 19 4 SCREW STEEL 29 INSULATING PAPER 19 5 SCREW SUS 304 34 CORRUGATED SPRING STEEL ITEM NAME MATERIAL PHOTO ITEM NAME MATERIAL PHOTO 1 CABLE H07 UL 13 PROTEC...

Страница 11: ...Figure 7 2AHS 2 HP For repair part please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List 10 Repair Parts barmesapumps com...

Страница 12: ...L SEAL NBR 27 FLANGE FC 15 11 IMPELLER HYTREL 28 AGITATOR SMF5030 OPTIONAL 11 Parts List For repair part please supply Model Number and Serial as shown on Name Plate and Part Description and Part Numb...

Страница 13: ...caused pump to stop 2 High liquid temperature has activated motor protector and caused pump to stop 3 Reverse rotation 1 Raise water level to C W L 2 Lower liquid temperature 3 Correct rotation Does...

Страница 14: ......

Страница 15: ......

Отзывы: