background image

8

4

Starting

When  starting  for  the  first  time  your 
equipment  check  that  the  discharge 
valve  is  90%  closed.  Gradually  open 
the  valve  until  the  motor  runs  at  full 
load  (amperage  plate).  Never  allow 
the  amperage  consumed  by  the 
pump 

exceeds 

the 

maximum 

permitted by the engine.

Mechanical  Seal  -

  To  inspect  or 

replace  the  shaft  seal,  remove  the 
body  and  impeller.  If  any  part  shows 
wear  or  damage,  replace  both  parts 
(stationary  seat  and  rotary  part). The 
rotating  seal  parts  may  be  stuck 
together with the shaft, this happens 
when  the  seal  has  been  assembled 
for a long time.

If  the  mechanical  seal  does  not  leak 
and there is need to open the pump 
for  inspection  or  cleaning, 

DO  NOT

 

remove  the  seal,  remove  the  spring 
only  if  the  impeller  needs  to  be 
removed.  Once  a  seal  has  been  in 
operation  is  very  difficult  to  remove 
and  reassembly  without  creating  a 
seal leak.

IMPORTANT! 

Always 

unplug  the  pump  before 
applying 

maintenance, 

service  or  repair  to  avoid 
electric shock.

Handle  seal  parts  with 
extreme  care.  DO  NOT 
damage  lapped  surfaces.

Operation & Maintenance

4

Mechanical seal

Mechanical  seals  installed  in  this 
pumps are lubricated by water, there 
for the pump should not be operated 
dry. You will find the appropriate seal 
for  each  use  and  liquid  to  be 
pumped,  check  with  your  Barmesa 
Pumps 

distributor 

for 

more 

information.

4

Stuffing box*

If  the  pump  has  graphite  packing 
(stuffing box) consider the following:

Ÿ

When  the  pump  is  placed  into 
operation, the liquid will drip from 
the  stuffing  box;  if  this  does  not 
happen,  loosen  the  nuts  on  the 
stuffing box until dripping occurs.

Ÿ

Once the pump has operated for a 
reasonable 

period 

and 

the 

dripping  has  not  decreased  to  "a 
few  drops  per  minute",  it  is 
necessary  to  tighten  the  nuts 
stuffing box. If tightening the nuts 
the  required  drip  is  not  achieved, 
the  graphite  packing  rings  must 
be replaced.

Ÿ

After  a  few  minutes  of  operation, 
gradually  tighten  the  nuts  until 
the  drip  decreases  but  does  not 
stop.

4

Frame*

All  pumps  come  with  factory 
lubricated  bearings.  It  is  very 
important  to  have  oil  in  the  oil  tank. 
(Use oil DTE26). Change the oil every 
1,000 hours of operation, considering 
a daily operation of 8 hours.

It  is  important  not  to  overfill  the  oil 
tank  because  it  would  cause  an 
increase  in  pressure  by  heating, 
affecting  the  bearings  and  seals.  In 
normal 

operation, 

the 

frame 

temperature  increases  122  °F  above 
ambient temperature.

*For Barmesa pumps with universal 
transmission.

4

Flexible coupling*

All  pumps  operated  through  flexible 
coupling or by pulleys and belts must 
be  perfectly  aligned  to  ensure 
smooth  operation.  In  no  case 
problems 

occur 

with 

flexible 

couplings 

if 

the 

pump-motor 

alignment  is  correct.  All  pumps  are 
manufactured 

following 

this 

condition.

4

Maintenance

Body  and Impeller  - 

All pump parts 

are removable by removing nuts and 
bolts. 

For 

body 

maintenance, 

disconnect 

the 

suction 

and 

discharge,  and  remove  the  body  of 
the 

intermediate 

coupling. 

For 

maintenance  of  the  impeller  is  not 
necessary  to  remove  the  suction  or 
discharge,  simply  remove  the  body 
nuts; this would uncover the impeller. 
Examine and replace if it shows wear 
or damage.

When 

the 

impeller 

requires 

replacement,  remove  the  screw  of 
the shaft, and using a puller, remove 
the  impeller  being  careful  not  to 
abuse the keyway of the shaft.

4

Disassembly

Mechanical Seal - 

Perform the steps 

above.  Remove  the  rotating  part.  It 
may  be  necessary  to  remove  the 
intermediate  link  to  remove  the 
stationary seat. To do this, remove the 
nuts  and  washers  that  attach  the 
coupling  to  the  motor.  When 
removing  the  coupling,  the  steady 
part will move towards the front seat 
of the shaft and the sleeve. If the seat 
does  not  yield  itself,  push  from  the 
rear of the coupling.

4

Reassembly

Mechanical Seal - 

Identify all parts of 

Figures 7

 and 

8

. The ring (6) and seat 

(1)  are  perfectly  polished,  so  care 
must  be  taken  not  to  scratch  or 
smudge.  The  cleaning  during  the 
assembly process is very important.

IMPORTANT!  -  All  parts 
must 

be 

clean 

before 

reassembly.

barmesa.com

Содержание 2-125 HP @ 1750 y 3500 RPM

Страница 1: ...Operation Maintenance Manual End Suction Centrifugal Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump IA series 2 125 HP 1750 y 3500 RPM Last update 07 22 2022...

Страница 2: ...before handling or servicing the pump or any accessory items associated with or near the pump Do not block or restrict the discharge pipe hose T h i s p u m p i s n o t i n t e n d e d f o r u s e i n...

Страница 3: ...ing dynamically balanced SEAL Mechanical type 01 Ceramic stationary part carbon ring seal and exclusion in the rotatingpart Buna Nelastomerandstainlesssteelspring SHAFTSLEEVE Stainlesssteel O RINGS Bu...

Страница 4: ...mp should be as close as possible to the liquid to be pumped with a minimum number of couplings adapters etc in order to reduce friction on the suction side The suction and discharge piping must be pe...

Страница 5: ...88 0 75 110 454 88 3 24 7 10 3 37 0 88 120 530 119 33 2 13 5 4 51 1 17 0 38 140 568 137 5 38 1 15 45 5 16 1 33 0 43 150 605 156 43 17 4 5 81 1 49 0 48 160 643 48 55 19 65 6 54 1 67 0 54 170 681 54 1...

Страница 6: ...75 3 36 STANDARD 45 ELBOW 0 38 0 54 0 61 0 77 0 92 1 15 1 53 1 83 2 29 STANDARD TEE 1 68 2 29 2 75 3 36 4 28 5 19 6 71 8 23 10 1 ANGLE GLOBE VALVE OPEN 3 97 5 49 6 71 8 23 10 7 12 2 16 8 21 3 25 9 GLO...

Страница 7: ...hese must be removed to allow trapped air to escape Use pipe or hose reinforced sufficiently robust to prevent destruction due to high pressure 4Discharge pipe Due to the cost of energy or BHP necessa...

Страница 8: ...stall the male plug using a sealant IMPORTANT Do not operate pump without priming first Operating dry will damage seal 4Pre Operation 1 Check Voltage and Phase Compare the voltage and phase informatio...

Страница 9: ...tighten the nuts until the drip decreases but does not stop 4Frame All pumps come with factory lubricated bearings It is very important to have oil in the oil tank Use oil DTE26 Change the oil every...

Страница 10: ...recommended that lightly polish the area of the shaft If the shaft and it radius are perfectly polished the seal can be relatively easily installed Step 2 Install the seat assembly 1 and 2 on the ins...

Страница 11: ...H 15 2 IA1 1 2H 20 2 IA1 1 2H 25 2 15 20 25 3530 3525 3525 3 3 3 254JM 256JM 284JM IA1 1 2H 3 4 3 1740 3 182JM IA1 1 2H 30 2 30 3525 3 286JM H 0 53 6 88 4 50 4 50 7 50 3 63 11 81 4 25 0 41 6 88 14 75...

Страница 12: ...11 Drawings barmesa com...

Страница 13: ...12 Drawings barmesa com...

Страница 14: ...13 Drawings barmesa com...

Страница 15: ...4 75 20 5 0 53 IA3H 40 2 40 3530 3 324JM 10 5 IA3H 50 2 50 3530 3 326JM 12 IA3H 60 2 60 3565 3 364JM 11 25 23 IA3H 75 2 75 3565 3 365JM 12 25 24 0 69 5 46 8 14 75 12 5 5 25 22 25 0 69 9 16 31 14 5 88...

Страница 16: ...PHASE FRAME A B C D E F G IA4 40 2 40 3530 3 324TSC 24 10 5 IA4 50 2 50 3530 3 326TSC 25 5 12 IA4 60 2 60 3565 3 364TSC 28 11 25 IA4 75 2 75 3555 3 365TSC 29 12 25 IA4 100 2 100 3560 3 405TSC 30 5 13...

Страница 17: ...20 25 10 4 25 10 6 25 9 9 IA4BJH 25 4 25 1760 3 284JM 22 62 9 5 IA4BJH 30 4 30 1760 3 286JM 24 56 11 IA4BJH 40 4 40 1765 3 324JM 25 31 10 5 IA4BJH 50 4 50 1765 3 326JM 25 31 12 IA4BJH 60 4 60 1765 3...

Страница 18: ...17 Drawings barmesa com...

Страница 19: ...er IA1 5 2 Dia 6 81 03140031C Impeller IA1 2 4 IA1 7 5 2 Dia 7 5 30400808 Shaft Sleeve 1 6 92010029J O Ring Shaft Sleeve 1 7 92010014 Slinger 1 8 31030131 Mechanical Seal 1 9 92010033 O Ring 1 10 9101...

Страница 20: ...0418 IMPELLER WASHER FOR 15 TO 50 HP 30400416 SHAFT KEY FOR 3 HP TO 7 5 HP 30400631 SHAFT KEY FOR 15 TO 50 HP 30400633 13 8 STUD 3 8 16X 1 50 91010303 14 8 HEX NUT 3 8 91010413 15 8 LOCK WASHER 3 8 91...

Страница 21: ...R IA1 XH 3 4 9 19 IMPELLER IA1 XH 5 4 9 19 5 1 SHAFT SLEEVE FOR 3 TO 25 HP 30400829 6 1 SLINGER FOR 3 TO 25 HP 92010016 7 1 MECH SEAL FOR 3 TO 25 HP 31030133 8 1 O RING 92010033 9 1 IMPELLER S SCREW F...

Страница 22: ...21 TYPICAL EXPLODED VIEW CENTRIFUGAL PUMP MODEL IA2 H Parts List barmesa com...

Страница 23: ...190 03140142B For 75 HP 3560 RPM 9 842 03140142C For 60 HP 3555 RPM 9 055 03140142D For 50 HP 3540 RPM 8 464 03140142E For 40 HP 3530 RPM 7 875 5 30400838 Shaft Sleeve 1 6 31030411 Mechanical Seal 1...

Страница 24: ...much The pump is operating in the range of NPSHR If reducing ow makes the noise gone then the problem is in the point above partially close the discharge valve The bearings for wear That there is oil...

Страница 25: ...ght to have the product returned to our factory for additional testing This warranty shall not apply when damage is caused by 1 improper installation 2 improper voltage 3 lightning 4 excessive sand or...

Отзывы: