background image

 

Dynalco SST7200 & SST7400 Software 
 

The  Dynalco  host  software  provides  serial  communication  between  a  PC  or  laptop  and  the 
SST7200  &  SST7400.  The  software  is  compatible  with Windows  XP,  Vista  and Windows  7 
operating systems. The SST7200 & SST7400 must be connected via provided Dynalco 

P/N 

270A-105574

 serial communication cable. 

 

 

The Dynalco host software is available as a free download from our website: 
 

downloads 

 
 

Following  installation,  a  shortcut  will  be  installed  on  your  PC  desktop.  This  application 
software  allows  access  to  various  screens  for  configuration  of  input  signal  sensitivity, 
proportional  output  and  relay  logic  /  setpoints.  Once  the  configuration  parameters  are  set, 
they can be programmed into the SST7200 & SST7400 and a spec file can be saved to the 
PC.  This  saved  spec  file  can  then  be  loaded  into  another  SST7200  &  SST7400  if  desired. 
Additionally, there is an import function allowing uploading of the spec file from an  SST7200 
& SST7400 to the PC 
 
 
Configuration consists of the steps described in the following pages: 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Dynalco SST7200

Страница 1: ...n and Operation Manual Rev G P N 145F 13129 PCO 00010927 c Copyright 2015 Barksdale Inc All Rights Reserved Published Oct 20 2015 DVNALCO DIGITAL DYNALCO SPEED SWITCH RELAY 1 _ RELAY 3 RELAY2 J RELAY...

Страница 2: ...age to this instrument and warranty invalidation For clarification of instructions in this manual or assistance with your application contact Dynalco as below Tech Support Technical dynalco support ba...

Страница 3: ...Overview The SST7200 SST7400 speed switches are DIN rail mountable products designed to convert rotational speed RPM to an industry standard 4 20 mA analog output Both models will accept a pulsed inpu...

Страница 4: ...o 20K load or higher or iii 0 10VDC into 20K load or higher Note that the 4 20 mA output is isolated but the 0 5 VDC 0 10 VDC outputs are referenced to input supply ground 0 1mA output is referenced t...

Страница 5: ...emperature coefficient 0 01 per F 0 018 per C 6 ALARM INDICATION a Open Pickup Alarm LED indication if open pickup sensed Option to trip relay b Trip Indication LED indication if a relay tripped condi...

Страница 6: ...e system enclosure the interior of which is accessible only through the use of a tool The suitability of the enclosure is subject to investigation by the local Authority Having Jurisdiction at the tim...

Страница 7: ...rtional Output REL1 NC Normally Closed Relay Contact REL1 CT Relay Common REL1 NO Normally Open Relay Contact REL2 NC Normally Closed Relay Contact REL2 CT Relay Common REL2 NO Normally Open Relay Con...

Страница 8: ...0 5 or 0 10 VDC Proportional Output DIG IN Digital Input for resetting latched relay 0 1mA 0 1 mA local meter output 0 1mA 0 1 mA local meter output RPM REP Repeater Output pulsed square wave 12V GND...

Страница 9: ...Outline Dimensions 4 50 1 1 liltl l 1 I i t IT l l alj 1 co RaAYt Q Q Ra An IEAY2 Q Q RB AH nQ POMRQ I 3 66 _______j DIGITAL LCO SPEED SWITCH RELAY 1 J RELAY3 RELAY 2 V J RELAY 4 RPM POWER 2 76 3 29...

Страница 10: ...llowing installation a shortcut will be installed on your PC desktop This application software allows access to various screens for configuration of input signal sensitivity proportional output and re...

Страница 11: ...e maximum time allowed between input signal pulses before a sensor fault is declared For example a shaft with 2 keyways turning at 0 10 RPM would have an extremely low frequency range calibrated below...

Страница 12: ...iod in milliseconds of the under speed setpoint Enable o Check this box to enable Signal Lost o If there is no under speed setpoint leave un checked Timeout o This is the maximum time in milliseconds...

Страница 13: ...either Setpoint 1 or 2 for the SST7200 o Select either Setpoint 1 2 3 or 4 for the SST7400 SST 7000 i Prog V ion 2 1 Cl DVNALCO 1tr 1 8VI 02 15q SST 7000 Series RPM Signal Signal Lost Open Pickup Ana...

Страница 14: ...than the RPM span RPM Span o Set to the RPM value corresponding to 20 mA output DVNALCO F 1 1 i1 V1 02Q l1SR SST 7000 Series RPM Signal Slgnal Lost Open Pickup Analog Output tPMZl rO RPtw Span y _ _ _...

Страница 15: ...Check this box to select latching relay must be manually reset following trip o A momentary contact from DIG IN digital input to VIN GND supply ground will reset latching relay Low o Selects under spe...

Страница 16: ...the PC SST 0005 nH v 2 2 DVNALCO F rl Mo eV1 0204f SST 7000 Series RPM Signal Signal Lost Open Pickup Analog Output Oe wteelh _ _ _ eo MaxWr leCUllbeln 000 __ Setpoint 1 tpolnt 2 jSelpoint 3 Setpolnt4...

Страница 17: ...relay outputs on the SST7200 SST7400 should be tested monthly for proper operation especially if being used for engine overspeed shutdown or other critical function SST 7000Stnts 9 _V 2 2 DVNALCO FrJT...

Страница 18: ...e pour les emplacements de Classe I Division 2 o WARNING EXPLOSION HAZARD Do not connect or disconnect while circuit is live unless area is known to be nonhazardous o AVERTISSEMENT RISQUE D EXPLOSION...

Страница 19: ...ITH SHIEID WIRE CONNECTED JO G ND TERMINAL 2 THESE UNITS ARE CERTIFIED FOR MOUNTING IN A SUITABLE ENCLOSURE SUITABILITY OF THE ANAL COMB INATIO N IS TO BE DET ERMINED BY CSA OR THE INSPECTION A UTHORI...