TT FSM User Manual

 

 

 

OPERATING MODES 

Operating Mode 

LED Color 

Log Data 

Offline 

Blue 

Onboard 

Online Authorization 

Purple 

Pc/Server 

Online Info 

Yellow 

Onboard 

Service 

Red 

--------- 

 

 

 

Offline Mode 

When the card is read, if it is authorized, the green light flashes up to draw 
the  relay  for  the  specified  time  out.  If  no  pass  is  authorized,  then  the  red 
light flashes. The card ID, date, time, pass direction are recorded in the unit 
database.  

 

Online Authorization 

The card is queused through the PC/server/host, and the blue light is up. If 
no response is received within the specified timeout period, the offline pass 
check is enabled. The after-pass authorization light codes are the same with 
the offline mode. No log data is stored by the unit.  

 

Online Info 

It  decides  in  offline  mode.  The  pass  information  is  also  transmitted  to 

 

PC/server/host. (Monitoring mode) Log is stored onboard. 

 

Service Mode 

The unit is set in this mode when an update is in progress in the unit, and in 
this case, no card is read, nor no pass is allowed.  

Содержание TT FSM

Страница 1: ...er Manual Barkodes Bilgisayar Sistemleri Bilgi İletişim ve Yazılım Tic Ltd Şti Adres Altay Çeşme Mahallesi Sanayi Sokak No 8 Demirli Sitesi B Blok Maltepe İstanbul Turkey Tel 90 216 442 20 62 Fax 90 216 459 04 84 Web www barkodes com tr Mail info barkodes com tr ...

Страница 2: ...BARKODES BİLGİSAYAR SİSTEMLERİ TT FSM 2 TT FSM User Manual TT FSM User Manual ...

Страница 3: ...BARKODES BİLGİSAYAR SİSTEMLERİ TT FSM 3 TT FSM User Manual Contents Preface 5 Safety Measures 6 Applications 7 Technical Data 7 Installation 8 Connection 9 Operating Modes 10 ...

Страница 4: ...ate time direction and card ID information through a dedicated RTC Real Time Clock and Flash Memory In Offline mode the authorized user details are defined through PC Server Host In Online mode the identification is completely performed by PC or the server If no response is received from PC Server Host it allows offline pass control It is possible to connect 8 units of TT FSM to a single line The ...

Страница 5: ...ot scratch the unit with a foreign substance DO NOT EXPOSE the unit to dirty or dusty spaces Do not operate the unit if there is a gas leak Keep the unit away from the strong magnetic or electrical fields Do not press or TOUCH the display panel DO NOT USE the unit in the vicinity of fuels rainy or humid zones SAFE TEMPERATURE 10C to 70 C operating temperature range INPIT VOLTAVE 8V 36V DC DO NOT D...

Страница 6: ...rating frequency Cart support Mifare Mifare Desfire UltraLight Mifare Plus Felica Jevel NFCIP1 card support Standard compliance ISO IEC 14443A ISO IEC 14443B ISO IEC 18092 NFC Standards Buzzer Yes Led warning Yes Read Write time 126ms Memory capacity CPU 16bit Risc CPU 12 Mips Low User memory Log memory Software Development Kit SDK C VB Net Optical isolation 1 Relay output External relay output No...

Страница 7: ...BARKODES BİLGİSAYAR SİSTEMLERİ TT FSM 7 TT FSM User Manual Installation You can easily install your product through the screw holes provided Screw holes Screw cover ...

Страница 8: ...BARKODES BİLGİSAYAR SİSTEMLERİ TT FSM 8 TT FSM User Manual Connection ...

Страница 9: ...rection are recorded in the unit database Online Authorization The card is queused through the PC server host and the blue light is up If no response is received within the specified timeout period the offline pass check is enabled The after pass authorization light codes are the same with the offline mode No log data is stored by the unit Online Info It decides in offline mode The pass informatio...

Отзывы: