background image

 

 

Barix Exstreamer Gold User Manual Version 01.01 

 

  

Page 

15 

 

7.7

 

Control settings 

These settings adjust the control ports, IR source and IR 
gateway properties. 

 

UDP command port

 

Define the port on which the device will receive commands 
via UDP.  

TCP command port 

Define the port on which the device will receive commands 
via TCP.

 

Web server port 

Defines the port where the web server of the Barix 
Instreamer can be reached. If set to 

"0" the default HTTP 

port (80) is used. 

IR Source 

Select "IR IN" when attaching an IR Receiver on the IR IN 
jack or "IR Serial Dongle" when using the supplied Serial 
Receiver. 

IR Gateway

 

When activated all received IR remote control commands 
will be transmitted to other Barix devices IR OUT output. 
Leaving the IP address at 0.0.0.0 and setting a valid port 
(not 0) will broadcast the IR commands in the LAN.  
To direct to a specific device set the IP Address of the 
device and the port (

Example: 192.168.0.24:12301).  

To disable the IR Gateway set the IP address to 0.0.0.0 and 
the port to 0. 

 

7.8

 

Serial settings 

These settings adjust the serial port, serial gateway and IR 
Dongle LED properties. 

Baud rate

 

Select the serial transmission speed (300 to 115200 Baud). 

 Data bits

 

Select 7 or 8 data bits. 

 

Parity

 

Select no, even or odd parity. 

Stop bits

 

Select 1 or 2 stop bits. 

 

Flow control

 

Select the type of flow control:  
none, software (XON/XOFF) or hardware (RTS/CTS). 

Local port

 

Defines the port on which the serial port can be accessed 
for serial gateway application. Only when "Local port" is set 
to "0" the serial port can be used as a command interface. 
If the active serial gateway is enabled and the "Local port" is 
set to a value then this will be the source port of the TCP 
connection. On 

"0" a random source port is used. 

Destination IP

 

To have this Barix Instreamer actively establish a serial 
gateway select the destination IP address to the device 
where the serial data will be transmitted to (and received 
from). 
Select "0.0.0.0" when the serial port is only used local. 

Destination port

 

Defines the port for the active serial gateway function (see 
destination IP). 

Notes

 

Both settings, "Destination IP" and "Destination port" have 
to be set to enable the gateway function. 

RTS function

 

Select the function of the RTS output pin. 
On "IR Status" the LED on the connected IR Dongle will 
flash upon reception of an IR Remote Control (default 
setting). On "activate AVR" RTS is on during streaming and 
60 sec after the last streaming. It can be used to activate an 
Audio Video Receiver or Amplifier. On "RTS" it can be 
used for flow control as usual or as an additional output.  

Содержание EXSTREAMER GOLD

Страница 1: ...MER GOLD Network amplified audio player for digital audio streaming in custom home installations and commercial applications User Manual Version 01 01 For Release 02 02 03 Dec 2004 Firmware Version 06 04 EXSTREAMER ...

Страница 2: ......

Страница 3: ...LAYLIST SETTINGS 14 7 7 CONTROL SETTINGS 15 7 8 SERIAL SETTINGS 15 7 9 SECURITY SETTINGS 16 7 10 REVERTING TO FACTORY DEFAULTS 17 7 11 REBOOTING THE DEVICE 17 7 12 UPDATING THE DEVICE 18 8 THE STEP BY STEP HOW TO 19 8 1 HOW TO SET A STATIC IP ADDRESS 19 8 2 HOW TO SET THE BARIX EXSTREAMER TO STREAM MUSIC FROM YOUR PC 19 8 3 HOW TO SET THE BARIX EXSTREAMER TO STREAM MUSIC FROM A SPECIFIC PC 19 8 4 ...

Страница 4: ...Barix Exstreamer Gold User Manual Version 01 01 Page 2 ...

Страница 5: ... listen to your MP3s being stuck in front of a computer or having to listen to high quality music through low quality computer speakers The Barix Exstreamer let you enjoy your music in any room of your home To make this manual easier to understand we have included a dictionary at the end of the manual that links to each technical word example DHCP 2 Features Streams MP3s from computers digital aud...

Страница 6: ...ght is static it means that the Barix Exstreamer found the zServer If the light is blinking it means that the Barix Exstreamer is streaming 5 Reset button Press this button to restart the device If you press it until the red light flashes about 5 seconds the device settings will be restored to the factory defaults A B C D E F G A RJ45 for LAN 10 100 Half Full duplex This port is for the connection...

Страница 7: ...laylists are After the correct path is entered click on set Skip the next step If you don t have any playlists created hit the browse button and click on the create folder icon to create a playlist folder for later use STEP 6 This is the playlist creation utility The first window asks for the location of your MP3s files Hit the upper browse button and show the program where they are If you click o...

Страница 8: ...utput B or an optical S PDIF output C to your digital audio input on your stereo both cables are not included 5 3 Installing the Barix Exstreamer to your network STEP 1 Plug the included network cable i into the network port of the Barix Exstreamer a and the other end into your hub or switch You can also use a crossover network cable not included for a direct connection to your PC STEP 2 Plug the ...

Страница 9: ...n top of the selected button and it will inform you of its function Click on the playlist title to start playing it You can also adjust the sound properties of the Barix Exstreamer by clicking on the SET button 6 1 User control interface PLAY This action plays the media file NEXT TRACK This action skips to the next media file in the playlist PREVIOUS TRACK This action skips to the previous media f...

Страница 10: ...e sound that both play is possible only on Exstreamer kitchen which becomes the sync master Once synchronized the name or the IP address of the sync master is displayed in the song list frame Click on the stop link to stop the synchronization To control the sync master click on the name of the device you have synchronized to When viewing the control panel of a sync master clicking any stop link wi...

Страница 11: ... a specific level or click or to increment decrement the treble level in steps LOUDNESS ON This action turns on the loudness level LOUDNESS OFF This action terminates the loudness level SET AS DEFAULT This action saves the current settings as default Every time you restart the Exstreamer it will use these settings LOCK VOLUME This action locks the volume level so it cannot be adjusted UNLOCK VOLUM...

Страница 12: ...s will bring you back to your starting point Clicking one of the playlists will show you the titles of this playlist Click it to go back or the folder above Click it to refresh the current list Click it to play the song or playlist Click it to play the subdirectory If a song a playlist or a subdirectory is playing it will appear the link Current Playlist Clicking this link will bring you to folder...

Страница 13: ...es not have to get a new one upon power up We recommend that you set a Static IP address IP Address Enter the 4 values of the desired device IP address e g 0 0 0 0 for automatic discovery in this order BOOTP DHCP IPzator AutoIP See also section 10 4 Automatic discovery settings 192 168 0 12 for an internal LAN Netmask Enter the 4 values of the desired Static IP e g 0 0 0 0 for a default Netmask de...

Страница 14: ...e to enter the IP address of your web server Server Port In this field you have to enter the port number on which your web server is communicating standard web server s work on port 80 A zero in this field indicates the default value port 80 Server Path In this field you have to enter the path where your playlists are stored on the web server Please note that you have to put a in front and at the ...

Страница 15: ...ing buffer underruns during an open TCP connection In this case one possibility is to disconnect the TCP connection The other option is to reconnect again the same stream Buffer Underrun Timeout The Buffer Underrun Timeout defines the amount of time in seconds since the streaming buffer is empty until the Buffer Underrun Mode action will be executed Number Of Reconnections The Number Of Reconnecti...

Страница 16: ...guration automatically 30 sec after the last change in the control interface The stored parameters are volume mute volume lock balance bass treble loudness on off shuffle and repeat 7 6 Playlist settings These settings adjust the playlist properties Own Name You can enter the name of the Barix Exstreamer here This name is displayed in the file info frame on the device status page This name will be...

Страница 17: ...ta bits Select 7 or 8 data bits Parity Select no even or odd parity Stop bits Select 1 or 2 stop bits Flow control Select the type of flow control none software XON XOFF or hardware RTS CTS Local port Defines the port on which the serial port can be accessed for serial gateway application Only when Local port is set to 0 the serial port can be used as a command interface If the active serial gatew...

Страница 18: ...to erase the current password View configuration password usage When the password is set the user clicking on the Config link has to type in the password in the password field of the pop up window the user name does not matter Only one user can log in at a time Further connections will be refused while one user is logged in To log out click on the Logout link next to the SECURITY tab in the menu b...

Страница 19: ...rtant note Use this method if connection to the Barix Exstreamer cannot be established This can happen if you have set a Static IP address once switched off SonicIP and then forgotten the IP address The hardware default settings reverts the IP Address to automatic discovery 0 0 0 0 and enables SonicIP If this fails we recommend downloading the Barix Exstreamer Gold Rescue Kit from www barix com Th...

Страница 20: ...ill see the following screen STEP 2 Click on Please click here to continue to launch the update process The device will restart in a special mode called Bootloader and the following screen appears showing a number counting down Upon start up the following screen appears ready for the update process STEP 3 To upload an update click on Browse to locate the file you want to update The file is named e...

Страница 21: ...uto detect in the Mode field STEP 7 Make sure that Server Port says 8888 STEP 8 Make sure that Server Path says STEP 9 Make sure that Playlist List Path says playlist html STEP 10 Hit the Apply button to save the changes The Barix Exstreamer will reboot STEP 11 After the reboot wait until the green LED stays steady zServer was found click on the HOME icon to get to the main page You should see now...

Страница 22: ... music 8 5 How to set the Barix Exstreamer to be a streaming puller For use with standard MP3 jukeboxes or many Web radio stations STEP 1 Open your Web Browser STEP 2 Enter the Barix Exstreamer s IP address and press Enter Example 192 168 0 12 STEP 3 Click on the Config link STEP 4 Click on the SERVER tab in the SETTINGS menu STEP 5 Choose 3 Streaming Puller in the Mode field STEP 6 In the Server ...

Страница 23: ... and announced the IP Address The function of this LED can be changed in the configuration Serial settings by the field RTS function see section 7 9 Serial settings The Installation is completed The Exstreamer can now be controlled through your IR remote control Enjoy the comfort and ease of use Mute Unmute the Barix Exstreamer s Output Switch to previous next song in the current playlist Decrease...

Страница 24: ...erial cable to your PC s COM port and to the serial port of the Barix Exstreamer STEP 5 Keep the Reset button pushed and plug in the power supply Release the Reset button as soon as you see following screen STEP 6 Hit s to skip network discovery if not connected to a network and the following screen appears STEP 7 Hit s to get to the Barix Exstreamer s setup STEP 8 Hit enter to enter the Barix Exs...

Страница 25: ... and other PC or embedded applications In the device configuration the serial port can be adjusted to suit your application For a detailed list of serial commands refer to the Exstreamer Technical Documentation available on the Barix website www barix com Ethernet UDP or TCP control commands The same control commands used on the serial port can be used as UDP or TCP commands over Ethernet For more...

Страница 26: ...Barix Exstreamer Gold User Manual Version 01 01 Page 24 ...

Страница 27: ...IP address correctly Check the cables to make sure the Barix Exstreamer is properly connected to the network Q Will the Barix Exstreamer work on my operating system A The Barix Exstreamer works on virtually any operating system because the zServer software is a portable java application that was designed to run regardless of which operating system it is on To control the Barix Exstreamer a standar...

Страница 28: ...Barix Exstreamer Gold User Manual Version 01 01 Page 26 ...

Страница 29: ...ore than one computer or network device Example A1 B2 C3 D4 E5 F6 Netmask A number used to identify a sub network so that an IP address can be shared on a LAN Local Area Network A mask is used to determine what subnet an IP address belongs to An IP address has two components the network address and the host address For example consider the IP address 150 215 17 009 Assuming this is part of a Class...

Страница 30: ...Barix Exstreamer Gold User Manual Version 01 01 Page 28 ...

Страница 31: ...pective owners and are used for reference only Barix Exstreamer Instreamer SonicIP and IPzator are trademarks of Barix AG Switzerland and are registered in certain countries For information about our devices and the latest version of this manual please visit www barix com Barix AG Seefeldstrasse 303 8008 Zurich SWITZERLAND Phone 41 43 433 22 11 Fax 41 1 274 2849 Internet web www barix com email sa...

Отзывы: