8 Application notes
This section will show you how to set the Annuncicom devices in common applications.
8.1 Two station intercom
Situation: two stations with one TALK button each.
Annuncicom’s default settings are already configured to allow two station intercom with only a few changes.
8.1.1 Station 1 configuration
Wiring
Station 1 is connected to an intercom panel:
Speaker to speaker out (C).
Microphone to Microphone In (E or F).
The TALK button to Input 0 (B1 and B3).
Network settings
If you have a DHCP Server in your network the device will automatically get an IP address and no changes
are needed.
Skip this step and go to Audio settings.
Use the following settings if you prefer to have a Static IP or if no DHCP server is available.
SonicIP is disabled; no need to hear it on power up as the IP Address is static and known and the device will
stay powered most of the time.
BARIX AG
| 28. Jan. 2014 | Application notes | Page 38/54
Station 1
192.168.0.10
LAN
Station 2
192.168.0.20
Intercom
Panel with one
button
Intercom
Panel with one
button
Содержание Annuncicom