61-101-00802.EF1 Revision J
Page | 25
(14) With the INS TEST POINT switch at SIG / RTN position, verify the T/S display
shows a value between 1500 and an “over range” of 1.
Note:
Ensure conductance is within specifications. If test results are outside limits,
repeat test.
(15) Set ON / OFF switch to OFF.
(16) Disconnect Probe adapter from Probe.
(17) Disconnect Probe adapter from T/S.
D. Discrete Level Sensor Test for C90 & C90A / B /GT /GTi / GTx
(1) Connect the T/S to the probe as shown in Figure 8 and the following setps.
Figure 8
Probe Discrete Level Interface
(2) Ensure the test leads, P/N 101-01012 banana plugs are connected to the
DISCRETE LEVEL SENSOR jacks.
(3) Connect the clip ends of test leads to probe DISCRETE LEVEL SENSORS leads as
specified in the following table.
Position
Connections
Upright
Inverted
Black & Blue
Lamp OFF
Lamp ON
Black & Orange
Lamp OFF
Lamp ON
Black & White
Lamp ON
Lamp OFF
Table 13
Discrete Level Sensor Continuity for C90 & C90A / B / GT / GTi / GTx
(4) With clip ends connected to black and blue leads of sensor, hold sensor vertically.
(5) Set T/S ON / OFF switch to ON.
(6) Invert probe at each connection and verify continuity results per Table 13.
(7) Set the T/S ON / OFF switch to OFF.