61-101-00802.EF2 (REV. G)
CH. 2
January 7, 2015
Page 33 of 44
exist, disconnect and clean the wing harness connector with
contact cleaner and gently blow dry. If the condition persists
disconnect and clean the fuel panel connector behind the LH
sidewall below the fuel panel in the same manner. When
cleaning the connectors be sure to include the test sets
connectors.
(58) Set the test set ON
/
OFF switch to OFF.
E.
Disconnecting or reconfiguring
(1) Open the circuit breakers.
Caution: When lowering or raising the fuel panel, ensure aircraft battery
switch is OFF and this battery is disconnected.
(2) Disconnect the test set ACFT connector from aircraft wiring plug or
the adapter cable.
(3) Disconnect the test set IND connector from the indicator or adapter
cable.
(4) Disconnect the adapter cable from the aircraft wiring and indicator.
(5) Connect the aircraft plug to indicator.
(6) Return the aircraft to original configuration.