2.

SYSTEM INSULATION MEASUREMENT

1.

Remove power from Aircraft Fuel Quantity System.

2.

Defuel Aircraft as per Aircraft Maintenance Manual
instructions.

CAUTION: Observe all safety precautions.

3.

Gain access to the Signal Conditioner.

4.

Break electrical connection.

5.

Connect the Adapter Harness A/C connector to mating Aircraft
wiring plug.

6.

Do not connect the Adapter Harness to the Signal Conditioner.

7.

Set the Test Set ON/OFF switch to ON.

8.

Set the INS TEST POINTS switch to GND/SH.

9.

Set the RANGE switch to X1.

10.

Set the TEST FUNCTION switch to the INSULATION position.

11.

Adjust the METER ADJUST to achieve an infinity indication on
the Test Set meter MEGOHM scale.

12.

Set the Test Set ON/OFF switch to OFF.

13.

Set the Adapter Harness IND. SELECT switch to A/C.

14.

Connect the Adapter Harness HI-Z COAX and LO-Z TANK jacks to
the Test Set HI-Z COAX and LO-Z TANK insulation jacks using 2
each 101-01008 (BNC to BNC) cables.

15.

Connect the GND jack of the Test Set to a good aircraft
ground using the 101-01007 cable.

16.

Set the Test Set ON/OFF switch to ON.

17.

Allow the Test Set time to stabilize.

18.

Insulation shall not be less than value specified in Table 1.

┌──────┬─────────────┬────────────┐

TEST

TEST POINTS

INSULATION

╞══════╪═════════════╪════════════╡

1

GND / SH

1000 MEG

Ω │

2

GND / LO-Z

1000 MEG

Ω │

3

GND / HI-Z

1000 MEG

Ω │

4

SH / LO-Z

1000 MEG

Ω │

5

SH / HI-Z

1000 MEG

Ω │

6

LO-Z / HI-Z

1000 MEG

Ω │

└──────┴─────────────┴────────────┘

TABLE 1

19.

Set the Test Set INS TEST POINTS switch for remaining Tests
per Table 1.

20.

Insulation shall not be less than values specified in Table
1.

21.

Set the Test Set ON/OFF switch to OFF.

Содержание 2548H

Страница 1: ...UCTION SUPPLEMENT FOR 2548H FUEL QUANTITY TEST SET P N 101 00420 WITH ADAPTER CABLE P N 101 00435 FOR CESSNA 402C S N 0001 ON 404 S N 0001 ON 414A S N 0001 ON 421C S N 0114 ON 61 101 00435 A1 June 22...

Страница 2: ...jacks using 2 each 101 01008 BNC to BNC cables 8 Place BNC shorting cap on Test Set LO Z COMP jack 9 Connect the GND jack of the Test Set to a good aircraft ground using the 101 01007 cable 10 Set the...

Страница 3: ...tion on the Test Set meter MEGOHM scale 12 Set the Test Set ON OFF switch to OFF 13 Set the Adapter Harness IND SELECT switch to A C 14 Connect the Adapter Harness HI Z COAX and LO Z TANK jacks to the...

Страница 4: ...Test Set manual for details 11 Release the pushbutton 12 Set Test Set TEST FUNCTION switch to CAP SIM 2 13 Set the Test Set ON OFF switch to OFF 14 Place BNC shorting cap on Test Set LO Z TANK jack 1...

Страница 5: ...vement can be made 33 With Indicator at 0 lbs set the Adapter Harness IND SELECT switch to T S 34 Test Set shall indicate 34 20 A 35 With Indicator at 620 lbs 402C 414A 421C or 1100 lbs 404 set the Ad...

Страница 6: ...e to 0 A as possible on the Test Set meter NOTE Refer to Test Set manual for details 12 Release the pushbutton 13 Set Test Set TEST FUNCTION switch to CAP SIM 2 14 Set the Test Set ON OFF switch to OF...

Страница 7: ...er to Test Set manual for details 28 Release the pushbutton 29 Set Test Set TEST FUNCTION switch to CAP SIM 2 30 Set the Test Set ON OFF switch to OFF 31 Return power to aircraft Fuel System 32 Adjust...

Отзывы: