barfield 2548H Скачать руководство пользователя страница 1

INSTRUCTION SUPPLEMENT

FOR

2548H FUEL QUANTITY TEST SET

P/N 101-00420

WITH

ADAPTER CABLE

P/N 101-00435

FOR

CESSNA

402C S/N 0001 & ON
404

S/N 0001 & ON

414A S/N 0001 & ON
421C S/N 0114 & ON

61-101-00435.A1

June 22, 1999

Содержание 2548H

Страница 1: ...UCTION SUPPLEMENT FOR 2548H FUEL QUANTITY TEST SET P N 101 00420 WITH ADAPTER CABLE P N 101 00435 FOR CESSNA 402C S N 0001 ON 404 S N 0001 ON 414A S N 0001 ON 421C S N 0114 ON 61 101 00435 A1 June 22...

Страница 2: ...jacks using 2 each 101 01008 BNC to BNC cables 8 Place BNC shorting cap on Test Set LO Z COMP jack 9 Connect the GND jack of the Test Set to a good aircraft ground using the 101 01007 cable 10 Set the...

Страница 3: ...tion on the Test Set meter MEGOHM scale 12 Set the Test Set ON OFF switch to OFF 13 Set the Adapter Harness IND SELECT switch to A C 14 Connect the Adapter Harness HI Z COAX and LO Z TANK jacks to the...

Страница 4: ...Test Set manual for details 11 Release the pushbutton 12 Set Test Set TEST FUNCTION switch to CAP SIM 2 13 Set the Test Set ON OFF switch to OFF 14 Place BNC shorting cap on Test Set LO Z TANK jack 1...

Страница 5: ...vement can be made 33 With Indicator at 0 lbs set the Adapter Harness IND SELECT switch to T S 34 Test Set shall indicate 34 20 A 35 With Indicator at 620 lbs 402C 414A 421C or 1100 lbs 404 set the Ad...

Страница 6: ...e to 0 A as possible on the Test Set meter NOTE Refer to Test Set manual for details 12 Release the pushbutton 13 Set Test Set TEST FUNCTION switch to CAP SIM 2 14 Set the Test Set ON OFF switch to OF...

Страница 7: ...er to Test Set manual for details 28 Release the pushbutton 29 Set Test Set TEST FUNCTION switch to CAP SIM 2 30 Set the Test Set ON OFF switch to OFF 31 Return power to aircraft Fuel System 32 Adjust...

Отзывы: