barfield 101-00901 Скачать руководство пользователя страница 4

 

56-101-00901 Revision F

 

 

Page iv 

MAINTENANCE AND REPAIR INFORMATION 

 
The manufacturer of this equipment does not recommend the user to attempt any maintenance or repair. 
In case of malfunction, contact the manufacturer to obtain the list of approved repair facilities worldwide, 
ensuring that this equipment will be serviced using proper procedures and certified instruments. 
 

BARFIELD PRODUCT SUPPORT DIVISION 

 
Telephone (305) 894-5400 
                  (800) 321-1039 
 
Fax            (305) 894-5401 
 

 

Email         

[email protected]

 

 

   

 
Shipping Address: 
 
Barfield, Inc. 
4101 NW 29th Street 
Miami, Florida 33142 
USA 
 

 

 
Mailing Address: 
 
Barfield, Inc. 
P.O. Box 025367 
Miami, FL 33102-5367 
USA 
 

 

 

Содержание 101-00901

Страница 1: ...2022 Barfield Inc All Rights Reserved USER INSTRUCTION MANUAL M N TT1000A P N 101 00901 Doc P N 56 101 00901 Revision F March 17 2022 ______________________________________ TT1000A Turbine Temperature...

Страница 2: ...ormation contained herein is the sole property of Barfield Inc No intellectual property rights are granted by the delivery of this document or the disclosure of its content This entire document is pro...

Страница 3: ...d user of this equipment to be able to obtain the service covered by the warranty Visit the company website http barfieldinc com for publication updates Please send the Registration Card to Barfield I...

Страница 4: ...to obtain the list of approved repair facilities worldwide ensuring that this equipment will be serviced using proper procedures and certified instruments BARFIELD PRODUCT SUPPORT DIVISION Telephone 3...

Страница 5: ...00890 January 27 2012 Updated to latest format specifications section changes D 260 00970 April 24 2013 Added instructions for using 45vdc voltage converter E 260 01025 September 19 2014 Update Barfi...

Страница 6: ...PHYSICAL CHARACTERISTICS 4 2 SPECIFICATIONS 4 3 CAPABILITIES 6 CHAPTER 2 OPERATION 7 1 OPERATING CONTROLS 7 2 GENERAL OPERATING INSTRUCTIONS 8 3 SYSTEM LEAD RESISTANCE TEST PROCEDURE 10 4 THERMOCOUPL...

Страница 7: ...ut 7 Figure 4 Voltage Conversion 9 LIST OF TABLES PAGE Table 1 Physical Characteristics 4 Table 2 Temperature Measurement 4 Table 3 Thermocouple Linearization 4 Table 4 Reference Junction Compensation...

Страница 8: ...couple outputs in degrees Celsius C B Thermocouple and lead resistance measurements to 0 01 and insulation measurements up to 2M C Simulates thermocouple outputs and system lead resistances from 0 to...

Страница 9: ...the supplied Warranty Registration Figure 1 Owner Warranty Registration Card B Each new or re certified unit is delivered with a Certificate not pictured that shows the date when the unit was tested b...

Страница 10: ...56 101 00901 Revision F Page 3 Figure 2 Limited 1 Year Warranty...

Страница 11: ...cy Typical measurement error at 25 C ambient less than 1 C National Institute of Standards Technology NIST Conformity Refer to Table 3 Reference Junction Compensation Refer to Table 4 see page 5 Error...

Страница 12: ...Ref Jct 1 5 NIST Conformity Temperature Coefficient 0 005 of Reading per C Table 5 Error Table B Lead Resistance 20 Range 0 19 99 in 0 01 increments 200 Range 0 199 9 in 0 1 increments Accuracy 0 1 of...

Страница 13: ...ates CH AL thermocouple with or without simulated system lead resistance D Measures and displays values of CH AL thermocouple in terms of degrees Celsius temperature E Automatically compensates for am...

Страница 14: ...BLACK pushbutton 5 when depressed with test leads connected to aircraft system and FUNCTION switch in RESISTANCE MEASURE position produces a display of the resistance in the system E The SHORT TEST L...

Страница 15: ...ighly recommends replacement of the batteries using the same CAUTION TO PREVENT BATTERY LEAKAGE 1 PROMPTLY REMOVE DEAD OR WEAK BATTERIES FROM THE TEST SET 2 NEVER MIX OLD AND NEW BATTERIES REPLACE ALL...

Страница 16: ...place the bulkhead of the panel assembly between the vertical guides in the carrying case and slide the assembly downward until the 45V battery connector can be connected and connect Then slide panel...

Страница 17: ...and then reversing the lead connections for the second measurement The true value is equal to the average of the two readings i e add the two readings and divide by two The two readings must be taken...

Страница 18: ...age 10 Note Resistance must be within manufacturer s specifications If results are slightly outside limits repeat entire procedure to ensure test failure is not due to human error I Place the ON OFF s...

Страница 19: ...lead clips to indicator terminals Observe polarity Alumel is negative and connects to the TT1000A BLACK clip Chromel is positive and connects to the TT1000A RED clip H Set TEMP ADJ control for the des...

Страница 20: ...nance Manual for specific values C Thermocouple Resistance Measurement 1 Disconnect aircraft power to indicator refer to the Aircraft Maintenance Manual 2 Follow the steps listed in section 4 THERMOCO...

Страница 21: ...e FUNCTION selector to TEMP MEASURE CAUTION AIRCRAFT INDICATORS OF THE D ARSONVAL TYPE MUST NOT BE CONNECTED DURING THIS TEST D ARSONVAL INDICATORS MAY GENERALLY BE RECOGNIZED BY THE ABSENCE OF A MULT...

Страница 22: ...o reship the TT1000A It is also recommended that the TT1000A and its carrying case be carefully inspected for damage If damaged immediately notify the carrier and the manufacturer 2 SHIPPING Use stand...

Отзывы: