1
CHECK:
Check the correct drive type, check suitable
motor type & info
2
PREPARE:
Correct tools, suitable mounting location,
weather protection
3
MOUNT:
Mechanical mounting
4
CONNECT:
Power & Control connections
5
CHECK:
Final check of everything before operation
6
POWER ON
7
COMMISSION
the drive parameters
8
OPERATE
and check everything is as intended
WARNING! The drive should ONLY be installed by a qualified electrician.
WARNING! In a residential environment, this product may cause radio
interference in which case supplementary mitigation measures may be required.
NOTE
This guide does not provide detailed installation, safety or operational instructions.
See the E3 IP66 Outdoor User Manual for complete information.
Unpack and check the drive. Notify the supplier and shipper immediately of any damage.
1 CHECK
Identifying the Drive by Model Number
Each drive can be identified by its model number, as shown in the table below.
E
-
3
-
1
2
0021 -
1
F
1
B
Product Family
IP Rating
IP66 FWD/REV Pot Disconnect
A
B
C
Generation
Dynamic Brake Transistor 1 = Not Fitted
4 = Internal Transistor
Frame Size
Filter Type 0 = No Filter
F = Internal EMC Filter
Input Voltage 1 = 110 – 115
2 = 200 – 240
4 = 380 – 480
No. Of Input Phases
Output Current x 10
2 PREPARE
Prepare the Mounting Location
The drive must be mounted in a vertical position only.
Installation should be on a suitable flat, flame resistant
surface. Do not mount flammable material close to the drive.
Refer to Technical Data and ensure the chosen mounting
location is within the drive specification.
The mounting location should be free from vibration.
Do not mount the drive in any area with excessive humidity,
corrosive airborne chemicals or potentially dangerous dust
particles.
Avoid mounting close to high heat sources.
The drive must not be mounted in direct sunlight. If
necessary, install a suitable shade cover.
The mounting location must be free from frost.
Do not restrict the flow of air through the drive heatsink.
The drive generates heat which must be naturally allowed
to dissipate. Correct air clearance around the drive must
be observed.
If the location is subject to wide ambient temperature
and air pressure variation, install a suitable pressure
compensation valve in the drive gland plate.
NOTE
If the drive has been in storage for a period longer than 2 years, the DC link capacitors must be reformed. Refer to
online documentation for further information.
Please scan the QR code
to access the complete
User Manual