1.
IMPORTANT
The equipment covered in this manual is to be installed
by trained, experienced service and installation
technicians. All duct work or portions thereof not in
the conditioned space should be properly insulated in
order to both conserve energy and prevent
condensation or moisture damage.
2. APPLICATION
This is a fan-assisted forced air gas furnace with
electric air conditioning for outdoor installation. A fan-
assisted furnace is equipped with an integral
mechanical means to draw products of combustion
through the combustion chamber and heat exchanger.
The furnace installation must conform with local
building codes and ordinances or, in their absence,
with the National Fuel Gas Code ANSI Z223.1 or
CAN/CGA-B149.1, latest edition, and the National
Electrical Code ANSI/NFPA-7 or CSA C22.1, latest
edition. It is the personal responsibility and obligation
of the purchaser to contact a qualified installer to
assure that installation is adequate and is in
conformance with governing codes and ordinances.
3.
DUCT WORK
The unit is designed for use with or without duct work.
See Warning on Page 7. Flanges are provided for
attaching the supply and return ducts. These
instructions explain the recommended method to install
the air cooled self-contained electric air conditioning
and gas heating unit and the electrical wiring
connections and gas piping to the unit. The refrigerant
system is completely assembled and charged. All
internal wiring is complete.
These instructions and any instructions packaged with
any separate equipment required to make up the entire
heating/cooling system should be carefully read before
beginning the installation. Note particularly “Starting
Procedure” and any tags and/or labels attached to the
equipment.
All duct work, supply and return, must be properly
sized for the design air flow requirement of the
equipment. Air Conditioning Contractors of America
(ACCA) is an excellent guide to proper sizing.
Refer to Table 9 for maximum static pressure available
for duct design.
AIR CONDITIONING MODULE OPTIONS
STD =
Standard equipment.
j
CCM Compressor control module has adjustable 30 second to 5 minute delay-on-break
timer. On initial power up, or any time the power is interrupted, the delay-on-make
will be 2 minutes plus 10% of the delay-on-break setting. There is no delay-on-
make during routine operation of the unit. The module also provides the lockout
feature (with 1 retry) for high and/or low pressure controls, and a 2 minute timed
bypass for low pressure control.
k
HPC High pressure control is auto reset. Always used with compressor control module
(CCM) which is included. See note
j
.
l
LPC Low pressure control is auto reset. Always used with compressor control module
(CCM) which is included. See note
j
.
m
LAC Low ambient control permits cooling operation down to 0°F.
1
M
C
C
2
C
P
H
3
C
P
L
4
C
A
L
d
e
ll
a
t
s
n
I
y
r
o
t
c
a
F
e
d
o
C
d
e
ll
a
t
s
n
I
d
l
e
i
F
t
r
a
P
D
T
S
D
T
S
%
G
6
1
-
A
M
C
D
T
S
D
T
S
%
%
H
8
1
-
A
M
C
D
T
S
D
T
S
%
I
6
-
A
M
C
Содержание WG241D
Страница 13: ...Manual 2100 376 Page 10 FIGURE 2A MOUNTING INSTRUCTIONS FOR WG42 WG48 AND WG60 MIS 1472 ...
Страница 16: ...Manual 2100 376 Page 13 FIGURE 6 COMMON WALL MOUNTING INSTALLATIONS MIS 1474 ...
Страница 22: ...Manual 2100 376 Page 19 FIGURE 11 LOW VOLTAGE WIRING MIS 1748 ...
Страница 23: ...Manual 2100 376 Page 20 FIGURE 11A LOW VOLTAGE WIRING ...
Страница 24: ...Manual 2100 376 Page 21 FIGURE 12 GAS PIPE CONNECTION MIS 1683 ...
Страница 34: ...Manual 2100 376 Page 31 26 LIGHTING AND SHUTDOWN INSTRUCTIONS FIGURE 15 INSTRUCTION LABEL ...
Страница 40: ...Manual 2100 376 Page 37 FIGURE 19 460 VOLT BLOWER MOTOR WIRING OPTIONS WG24 WG30 AND WG36 MODELS MIS 1725 ...
Страница 41: ...Manual 2100 376 Page 38 FIGURE 20 460 VOLT BLOWER MOTOR WIRING OPTIONS WG42 WG48 AND WG 60 MODELS MIS 1487 ...
Страница 56: ...Manual 2100 376 Page 53 WG241DA 230 208 60 1 ...
Страница 57: ...Manual 2100 376 Page 54 WG241DA 230 208 60 1 ...
Страница 58: ...Manual 2100 376 Page 55 WG241DB 230 208 60 3 ...
Страница 59: ...Manual 2100 376 Page 56 WG241DB 230 208 60 3 ...
Страница 60: ...Manual 2100 376 Page 57 WG241DC 460 60 3 ...
Страница 61: ...Manual 2100 376 Page 58 WG241DC 460 60 3 ...
Страница 62: ...Manual 2100 376 Page 59 WG301DA WG361DA 230 208 60 1 ...
Страница 63: ...Manual 2100 376 Page 60 WG301DA WG361DA 230 208 60 1 ...
Страница 64: ...Manual 2100 376 Page 61 WG301DB WG361DB 230 208 60 3 ...
Страница 65: ...Manual 2100 376 Page 62 WG301DB WG361DB 230 208 60 3 ...
Страница 66: ...Manual 2100 376 Page 63 WG301DC WG361DC 460 60 3 ...
Страница 67: ...Manual 2100 376 Page 64 WG301DC WG361DC 460 60 3 ...
Страница 68: ...Manual 2100 376 Page 65 WG422DA 230 208 60 1 ...
Страница 69: ...Manual 2100 376 Page 66 WG422DA 230 208 60 1 ...
Страница 70: ...Manual 2100 376 Page 67 WG422DB 230 208 60 3 ...
Страница 71: ...Manual 2100 376 Page 68 WG422DB 230 208 60 3 ...
Страница 72: ...Manual 2100 376 Page 69 WG422DC 460 60 3 ...
Страница 73: ...Manual 2100 376 Page 70 WG422DC 460 60 3 ...
Страница 74: ...Manual 2100 376 Page 71 WG481DA WG601DA 230 208 60 1 ...
Страница 75: ...Manual 2100 376 Page 72 WG481DA WG601DA 230 208 60 1 ...
Страница 76: ...Manual 2100 376 Page 73 WG481DB WG601DB 230 208 60 3 ...
Страница 77: ...Manual 2100 376 Page 74 WG481DB WG601DB 230 208 60 3 ...
Страница 78: ...Manual 2100 376 Page 75 WG481DC WG601DC 460 60 3 ...
Страница 79: ...Manual 2100 376 Page 76 WG481DC WG601DC 460 60 3 ...