![Bard Q-TEC QH Series Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/bard/q-tec-qh-series/q-tec-qh-series_installation-instructions-manual_4201873051.webp)
Manual 2100-742B
Page
51 of 57
1
Values listed are with ventilation package disabled
2
Return air temperature °F @ Default airflow (825 CFM) for AC tests and Balanced Climate airflow (600 CFM) for
dehumidification tests
3
Suction pr/- 4 psi, Discharge pr/- 10 psi
DB/WB
2
OD Temp.
75°F
85°F
95°F
Mode
A/C
Dehum
A/C
Dehum
A/C
Dehum
75/64.1
(55% RH)
Total Cooling Btuh
25,100
10,000
23,500
6,300
21,600
1,900
Sensible Btuh
18,200
3,000
17,500
300
16,800
(2,600)
S/T
0.725
0.30
0.745
0.05
0.778
0
Latent Btuh
6,900
7,000
6,000
6,000
4,800
4,500
Lbs. H20/hr.
6.5
6.6
5.7
5.7
4.5
4.2
Supply Air DB
55.1
70.6
55.9
74.7
56.7
78.9
Supply Air WB
53.9
58.9
54.6
60.9
55.4
63.1
Suction PSIG
3
132
125
134
127
136
132
Discharge PSIG
3
303
265
345
295
392
327
75/65.5
(60% RH)
Total Cooling Btuh
26,000
10,900
24,300
7,500
22,500
3,200
Sensible Btuh
17,300
4,500
16,400
1,800
15,700
(1,000)
S/T
0.665
0.413
0.675
0.240
0.698
0
Latent Btuh
8,700
6,400
7,900
5,700
6,800
4,200
Lbs. H20/hr.
8.2
6.0
7.5
5.4
6.4
4.0
Supply Air DB
56.1
71.6
57.0
75.6
57.9
79.9
Supply Air WB
55.0
59.9
55.9
61.8
56.7
64.0
Suction PSIG
3
134
128
137
130
139
134
Discharge PSIG
3
224
268
320
298
367
330
75/66.7
(65% RH)
Total Cooling Btuh
26,900
12,200
25,200
8,700
23,400
4,400
Sensible Btuh
16,200
6,100
15,400
3,300
14,600
500
S/T
0.602
0.50
0.611
0.38
0.624
0.11
Latent Btuh
10,700
6,100
9,800
5,400
8,800
3,900
Lbs. H20/hr.
10.1
5.8
9.2
5.1
8.3
3.7
Supply Air DB
57.3
72.6
58.2
76.6
59.0
80.8
Supply Air WB
56.3
60.8
57.2
62.7
58.0
64.9
Suction PSIG
3
137
131
139
133
141
137
Discharge PSIG
3
199
271
294
300
342
333
Q24H4D Cooling and Dehumidification Application Data
1
Содержание Q-TEC QH Series
Страница 16: ...Manual 2100 742B Page 16 of 57 MIS 2471 A REMOVE KNOCK OUT FOR INDOOR DRAIN HOSE CONNECTOR FIGURE 18C If used...
Страница 43: ...Manual 2100 742B Page 43 of 57 GRAPH 1 Q24H4 FAD Ventilation Delivery GRAPH 2 Q30H4 FAD Ventilation Delivery...
Страница 44: ...Manual 2100 742B Page 44 of 57 GRAPH 4 Q43H4 FAD Ventilation Delivery GRAPH 3 Q36H4 FAD Ventilation Delivery...
Страница 45: ...Manual 2100 742B Page 45 of 57 GRAPH 5 Q48H4 FAD Ventilation Delivery...