![Bard CRVS-5A Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/bard/crvs-5a/crvs-5a_installation-instructions-manual_3843359006.webp)
Manual 2100-760
Page
6 of 17
5. For Installation of Left Hand Units Only
Remove strain relief in right side of CRVS (see
Figure 3). Unclip the two (2) wire ties holding the
wire harness. Reroute wires to left side of CRVS.
Re-install wire ties in left side holes. Route wires
through left side and re-install strain relief.
FIGURE 3
Reroute Wires for Left Hand CRVS-5A Units Only
6. Insert ventilator into the unit to the far left side
clearing the right filter bracket (see Figure 4).
Once the ventilator is fully inserted, slide the
ventilator to the right until it is tight against the
back of the control panel.
MIS-4341
FOR LEFT HAND UNITS
WIRED FOR RIGHT HAND UNITS.
LEFT END
FOR LEFT HAND UNITS, UNCLIP WIRE TIE
THROUGH LEFT END, REINSTALL
STRAIN RELIEF
RIGHT END
FOR LEFT HAND UNITS, REWIRE
STRAIN RELIEF & ROUTE WIRES
RE-CLIP WIRE TIE HERE
BASE