Manual 2100-719
Page
23 of 25
TABLE 7
C**H INDOOR BLOWER PERFORMANCE - CFM (0.00" — 0.50" H
2
0)
Model
Rated
ESP
MAX
ESP
k
Blower
Only
Cooling
& Heat Pump
Stage 1
Cooling
& Heat Pump
Stage 2
Electric
Heat
C24H
.10
.50
550
550
740
900
C30H
.10
.50
650
650
900
900
C36H
.15
.50
800
800
1100
1100
C42H
.15
.50
800
900
1250
1250
C48H
.20
.50
825
1000
1550
1550
C60H
.20
.50
850
1300
1650
1650
NOTE: These units are equipped with a variable speed (ECM) indoor motor that automatically adjusts itself to maintain approximately
the same rate of indoor airflow in both heating & cooling, dry & wet coil conditions and at both 230/208 or 460 volts.
Maximum ESP (inches WC) shown is with 2" thick disposable filter.
k
Blower only CFM is the total air being circulated during continuous fan mode. Airflow remains constant.
Blower only CFM reduces during continuous fan mode. Requires wiring modification; consult Installation Instructions & Wiring Diagram.
CFM output on Cooling or Electric Heat.