Bard 8620-343 Скачать руководство пользователя страница 2

Manual 7960-918
Page 

2 of 9

Personal Protective Equipment (PPE)

UV radiation is absorbed by clothing, plastic or glass. 
Once absorbed, the UV radiation is no longer active. 
Wear UV goggles or face shield. Cover any exposed skin 
with coats, gloves, etc.

UV-C band light spectrum is not visible to the eye.

NOTE:

 

The health aspects associated with the use of 
this product and its ability to aid in disinfection 
of environmental air have not been investigated 
by UL.

NOTE: 

Color shift or chalking may occur without 
affecting structural properties.

Product Specifications

Model

Olympia UV-C Light F15T5-15W-UVC-DL

Electrical Specs

Input Voltage

120-277VAC

Power Consumption

15W

Frequency

50/60Hz

Dimensional Specs

Unit Dimensions

15-1/8" L x 3/4" H x 1" D

Weight

1 lb

Performance

Irradiance

170µW/cm

2

UL Listing and Certifications

Compliance and 
Certifications

UL 1598

CSA C22.2#250.0

UL 8750

UL 2043

CE

RoHS Directive

“UV-C LED Light Bar Installed” Label 7961-622-0375 
is located near unit serial plate

Kit

Voltage

Wall-Mount Models

8620-343

460V

W**A2,W**AA, W**AB

W**L2, W**LA, W**LB

W**H2, W**HA, W**HB

W*SAC, W*RV, W*LV

8620-344

230V

MIS-4309

MAGNETIC CLIPS

8

3/4"

"

1"

15

1

10"

(REF)

Dimensions

Overview 

The UV-C field-installed light kits utilize UV-C LED 
lighting technology to sterilize and improve overall air 
quality within an occupied space. UV-C exposure is 
proven to damage the DNA of microorganisms and render 
them inactive aiding in preventing the spread of diseases.

These instructions are applicable to the following models:

Содержание 8620-343

Страница 1: ...ng locations that prevent exposure to vulnerable components If mounting locations are limited protect components with UV resistant material such as aluminum foil aluminum duct tape metallic shields et...

Страница 2: ...sumption 15W Frequency 50 60Hz Dimensional Specs Unit Dimensions 15 1 8 L x 3 4 H x 1 D Weight 1 lb Performance Irradiance 170 W cm2 UL Listing and Certifications Compliance and Certifications UL 1598...

Страница 3: ...rlock Safety Device 1 E 113 908 Bracket WH Q TEC Q H A4 Units 1 F 113 909 Bracket I TEC Units 1 G 113 913 Bracket Q TEC Units 1 H 7961 963 UV C Warning Label 1 I Per Model Supplemental Instructions Ma...

Страница 4: ...tor or control box mounted to blower partition however UV light can still be installed as shown 6 Route wires into control panel through bushing in blower partition or copper grommet or wire bushing t...

Страница 5: ...2 Kit 8620 343 460V Stepdown Transformer Installation Locations MIS 4336 TRANSFORMER COVER NOT REQUIRED IN UNIT CONTROL PANEL ON BOTTOM BLOWER PARTITION TRANSFORMER COVER REQUIRED ON TOP BLOWER PARTI...

Страница 6: ...or light 13 Control panel assemblies vary due to available control options Find unused space on control panel and install relay and indicator light assemblies in control panel using self drilling scre...

Страница 7: ...R SWITCH ASSEMBLY LOCATION WHEN NO DEFLECTOR IS USED DOOR SWITCH ASSEMBLY USE BRACKET 113 908 ROUTE WIRES BEHIND DEFLECTOR AND THROUGH BUSHINGS TO CONTROL PANEL SHOWN WITH DEFLECTOR INSTALLED 1 3 4 IN...

Страница 8: ...stalled Label 7961 622 0375 to unit serial plate Serial plate is silver and located on the exterior of the unit cabinet or on a service panel with 5253 039 XXXX printed in the lower right corner 20 No...

Страница 9: ...CK WHITE BLACK WHITE ORANGE RED BLACK RED ORANGE BLACK WHITE NO COM T2 T1 L2 DOOR PANEL SWITCH UNIT SUPPLY VOLTAGE 460 VOLT 3 PHASE 230 VOLT 3 PHASE UNIT SUPPLY VOLTAGE UNIT SUPPLY VOLTAGE 230 VOLT 1...