Barcol-Air CERA NXOJOOB Скачать руководство пользователя страница 5

5

© 01-2022 | Barcol-Air B.V. | T +31 (0)299 689 300 | www.barcol-air.nl | www.cera-systeem.nl | Changes w/o notice or obligation.

CERA units | type NXOJOOB

Technical information

Application

-  CERA units are pressure-independent fresh outside air volume control 

units (ventilation units) suitable for stacked housing. The units have 

been designed particularly for systems with low noise criteria and for 

the accurate measurement and control of air volumes courtesy of the 

patented air flow sensor type Flo-Cross

®

.

The CERA unit controls the amount of fresh air supplied to the room 

based on the measured CO

2

 level and features override options using 

switches, all of which save energy. The CERA unit controls the amount 

of fresh air supplied to the room based on the measured CO

2

 levels 

between a factory calibrated minimum and maximum set-point. It will 

provide increased air volumes when the ‘cooking’ function or ‘bathroom’ 

function is activated. When the ‘night’ function is active it will provide 

reduced but suffi  cient fresh air for the occupants. This way the CERA 

is a very energy conscious system, which will contribute to your green 

building certifi cation.

The units take up very little space and are suitable for use in new or 

refurbishment projects (renovations/transformation). The units are 

maintenance free and do not contain fi lters or a fan.

BENG calculation

BENG stands for Nearly Zero Energy Buildings and is applicable since 

01-01-2021 and did replace the EPC calculation. The BENG calculation 

is required for applying for a new building environmental permit and 

calculate the Energy Performance component. 

The energy performance of a building is determined with the new 

determination method NTA 8800. 

Technical information

The compact, low-noise units are internally lined; the air fl ow does not 

come into contact with the insulating material and the units do have 

supply and return spigots. The supply and return air run synchronously 

with each other and ensure air balance in the apartment. Two versions of 

the CERA system are available: the one-zone system (CERA-1) and the 

two-zone system (CERA-2). 

The CERA-2 unit has an extra air damper which controls the air fl ow 

more accurately between the diff erent rooms. On the air side, it features 

a specially-designed servo-actuated 3-way valve that directs air to the 

main zones & the sub zones depending on the need. 

The CERA PLUS system can be connected to several CO

2

 sensors for 

several bedrooms and/or other rooms. The highest CO

2

 value measured 

will be used in the air volume calculation. The CERA PLUS system is 

available for the CERA-1 (up to 5 sensors) and the CERA-2 (up to 6 

sensors).

The units and the system are not suitable for direct connection to 

a motorless or motorised kitchen hood. 

TYPE

CERA-1 | CERA-2

CERA-1 | 1 zone system

CERA-2 | 2 zone system

Содержание CERA NXOJOOB

Страница 1: ...www airselect nl TYPE NXOJOOB TOTAL VENTILATION CONCEPT FOR STACKED HOUSING TOTAL VENTILATION CONCEPT FOR STACKED HOUSING CO2 CONTROLLED FRESH OUTSIDE AIR VENTILATION SYSTEM ONLINE SELECTION TOOL...

Страница 2: ...dependent control Low pressure loss Individual room control up to 6 nos rooms High accurate air ow control Flo Cross air ow sensor air ow sensor Plug Play including factory calibrated BACnet controlle...

Страница 3: ...s Index TYPE CERA 1 CERA 2 Type designation 4 Technical information 5 Technical information delivery format 6 Speci cation 7 Assembly and installation intructions 8 CERA 1 Dimensions 9 Performance dat...

Страница 4: ...t coil O O without reheat coil Position 6 Controls type and function O O without controls Position 7 Sensor B O not applicable B Flo Cross 2 x 12 point averaging 2 x 12 point averaging and signal ampl...

Страница 5: ...contain lters or a fan BENG calculation BENG stands for Nearly Zero Energy Buildings and is applicable since 01 01 2021 and did replace the EPC calculation The BENG calculation is required for applyin...

Страница 6: ...ogen free The controller is supplied with dedicated CERA 1 or CERA 2 software Upon request the system can be set up and remotely controlled It is recommended to opt for the optional remote setup and m...

Страница 7: ...n bearings Completed with Flo Cross 2x12 points 2x12 points averaging and signal amplifying air ow sensors better than 2 5 accuracy even with irregular duct approach Units supplied with DDC controller...

Страница 8: ...and measuring tubes must be accessible at all times control equipment is mounted on the inner side and can be reached via a hinged ap The unit must be clean dust free and dry when tted and connected...

Страница 9: ...490 C 265 293 333 D 158 158 198 E 350 350 430 F 100 100 120 G 210 210 250 Kg 14 4 14 8 17 0 Model CERA 1 Remarks dimensions 1 All dimensions are in mm 2 Other dimensions available on request Home sid...

Страница 10: ...Volume Lw in dB Oct re 1pW Lp values dB A NC NR dB dB dB Lw in dB Oct re 1pW Lp values Lw in dB Oct re 1pW Lp values dB A NC NR TYPE CERA 1 Sound data pressure drop 100 Pa 125 Hz 250 Hz 500 Hz 1000 H...

Страница 11: ...cable signal cable Power Outlet 230Vac Power Outlet 230Vac CO sensor push button switch 24V 0V OP1 OP2 OP3 0V 24 V 0 5 V 0 2000 ppm 0 V 0 5 V 0 40 C N A CERA S TCO2 24V 0V OP1 OP2 OP3 0V 24 V 0 5 V 0...

Страница 12: ...emand driven CO2 control In reduced mode night sleep mode the required air volume will be set to a xed value of 75 MaxFlow regardless of the CO2 reading After 13 hours night sleep setting the control...

Страница 13: ...338 373 453 K x 109 129 L x 118 138 Kg 21 2 23 4 29 2 Model CERA 2 Dimensions en weight CERA 2 CERA 2 type NXOJOOB Dimensions TYPE CERA 2 Remarks dimensions 1 All dimensions are in mm 2 Other dimensi...

Страница 14: ...42 31 22 24 59 54 48 42 37 30 34 36 29 24 22 21 22 8 244 517 878 89 72 67 59 54 50 45 33 25 27 61 56 50 45 39 32 22 36 39 33 27 24 22 25 10 305 646 1097 139 X X X X X X X X X X X X X X X X X X X X X X...

Страница 15: ...1 OP2 OP3 0V 24 V 0 5 V 0 2000 ppm 0 V 0 5 V 0 40 C N A CERA S TCO2 24V 0V OP1 OP2 OP3 0V 24 V 0 5 V 0 2000 ppm 0 V 0 5 V 0 40 C N A CERA S TCO2 24V 0V OP1 OP2 OP3 0V 24 V 0 5 V 0 2000 ppm 0 V 0 5 V 0...

Страница 16: ...volume will be maximum regardless of the measured CO2 value it will be equally 50 50 divided between the two zones After 60 minutes the control sequence will automatically return to the demand driven...

Страница 17: ...17 01 2022 Barcol Air B V T 31 0 299 689 300 www barcol air nl www cera systeem nl Changes w o notice or obligation CERA units type NXOJOOB CE Declaration of Conformity TYPE CERA 1 CERA 2...

Страница 18: ...BARCOL AIR AIR DISTRIBUTION Cantekoogweg 10 12 1442 LG Purmerend The Netherlands T 31 0 299 689 300 E export barcol air nl OUR TECHNOLOGY YOUR WELLBEING WWW BARCOL AIR NL...

Отзывы: