11
4.3.1
Gap sensor detection
This measurement is used to determine the sensitivity of the label paper
sensor after the printer is turned on (Sensitivity). When the user replacement of
different specifications of the roll or the printer will initialize (Initialization) reduced
the set values for the factory set value, namely the need to re label paper
determination of gap sensor. To detect the gap or black marker is in accordance
with the correction of the last time you set value. The default value of this printer
sensor is set to the gap correction.
Follow these steps
:
1. Power off the printer
2. Press the key to open the printer power supply
3. In the first light purple, red flashing, release the feed key
Indicator color cycle mode
:
Blue and purple Blue Blue and purple Red(flashing 5 times) Blue
and purple(flashing 5 times) Blue(flashing 5 times)
Blue(fixed)
Be careful
:
Please select gap or black mark sensor by GAP command prior to calibrate
the sensor.
For more information about GAP command, please refer to programming
manual.
Internal Network Adaper Boot
Indicator color cycle mode:
Indicator light
function
Blue and
purple
Blue
Blue and
purple
Red
Blue and
purple
Blue
Blue
(flashing 5
times)
(flashing 5
times)
(flashing 5
times)
fixed
1.Gap sensor detection
Release
button
2. The gap sensor detects, print and enter
the value of self testing debugging mode
Release
button
3. Printer initialization (restore factory
defaults)
Release
button
4. Skip
AUTO.BAS
program
Release
button
Содержание XP-DT108B
Страница 1: ...XP DT108B DIRECT THERMAL BARCODE PRINTER USER S MANUAL Direct Thermal Printer...
Страница 11: ...9...