HD
Hazard Distance (HD) is the distance measured from the projection lens at which the intensity or the energy
per surface unit becomes lower than the applicable exposure limit on the cornea or on the skin. The light beam
is considered (to be) unsafe for exposure if the distance from a person to the light source is less than the HD.
HD
Hazard Distance (HD) is the distance measured from the projection lens at which the intensity or the energy
per surface unit becomes lower than the applicable exposure limit on the cornea or on the skin. The light beam
is considered (to be) unsafe for exposure if the distance from a person to the light source is less than the HD.
Light processor unit
Heart of the projector, unit inside this projector which is responsible for the creation of the image to be
projected on the screen. Also called 'engine'.
Scheimpflug principle
The "plane of sharp focus" can be changed so that any plane can be brought into sharp focus. When the DMD
plane and lens plane are parallel, the plane of sharp focus will also be parallel to these two planes. If, however,
the lens plane is tilted with respect to the DMD plane, the plane of sharp focus will also be tilted according to
geometrical and optical properties. The DMD plane, the principal lens plane and the sharp focus plane will
intersect in a line below the projector for downward lens tilt.
DMX
DMX-512 Lighting protocol over RS-485 interface. Carries information of 512 channels from a lighting
controller to lighting devices. Standardized by USITT.
RS232
An Electronic Industries Association (EIA) serial digital interface standard specifying the characteristics of the
communication path between two devices using either D-SUB 9 pins or D-SUB 25 pins connectors. This
standard is used for relatively short-range communications and does not specify balanced control lines. RS-
232 is a serial control standard with a set number of conductors, data rate, word length and type of connector
to be used. The standard specifies component connection standards with regard to computer interface. It is
also called RS-232-C, which is the third version of the RS-232 standard, and is functionally identical to the
CCITT V.24 standard. Logical '0' is > + 3V, Logical '1' is < - 3V. The range between -3V and +3V is the
transition zone.
RS422
An EIA serial digital interface standard that specifies the electrical characteristics of balanced (differential)
voltage, digital interface circuits. This standard is usable over longer distances than RS-232. This signal
governs the asynchronous transmission of computer data at speeds of up to 920,000 bits per second. It is also
used as the serial port standard for Macintosh computers. When the difference between the 2 lines is < - 0.2V
that equals with a logical '0'. When the difference is > +0.2V that equals to a logical '1'..
R5906113 /08
UDX
145
Glossary
Содержание UDX
Страница 1: ...ENABLING BRIGHT OUTCOMES Installation Manual UDX...
Страница 8: ...R5906113 08 UDX 8...
Страница 32: ...R5906113 08 UDX 32 Installation preparations...
Страница 40: ...R5906113 08 UDX 40 Pulse Remote Control Unit...
Страница 86: ...R5906113 08 UDX 86 WiFi GSM Module...
Страница 92: ...R5906113 08 UDX 92 Laser range finder camera kit...
Страница 102: ...R5906113 08 UDX 102 Getting Started...
Страница 130: ...R5906113 08 UDX 130 Specifications...
Страница 131: ...131 R5906113 08 UDX Stacking UDX projectors B...
Страница 134: ...R5906113 08 UDX 134 Stacking UDX projectors...
Страница 144: ...R5906113 08 UDX 144 Overview video timings for video interfaces...