R5906113 /09
UDX
17
Based on national requirements, no person is allowed to enter the projected beam within the zone between
the projection lens and the related hazard distance (HD). This shall be physically impossible by creating
sufficient separation height or by placing barriers. The minimum separation height takes into account the
surface upon which persons other than operator, performers or employees are permitted to stand.
On Image 1-3 a typical setup is displayed. It must be verified if these minimum requirements are met. If
required a restricted zone (RZ) in the theater must be established. This can be done by using physical barrier,
like a red rope as illustrated in Image 1-3.
The restricted area sticker can be replaced by a sticker with only the symbol.
P
R
RESTRICTED
AREA
R
E
S
T
R
I
C
T
E
D
A
R
E
A
Image 1-3
USA market
For LIPs (Laser Illuminated Projectors) installed in the USA market other restriction zone conditions apply.
LIPs for installation in restrained environment (cinema theaters, business rooms, class rooms, museums ...)
shall be installed at height vertically above the floor such that the bottom plane of the hazard distance zone
shall be no lower than 2.5 meters above the floor. Horizontal clearance to the hazard distance zone shall be
not less than 1 meter. Alternatively, in case the height of the separation barrier for the horizontal clearance is
at least 1 meter high then the horizontal clearance (SW) can be reduced to:
•
0 meter if the height of the hazard zone is minimum 2.5 meter.
•
0.1 meter if the height of the hazard zone is minimum 2.4 meter.
•
0.6 meter if the height of the hazard zone is minimum 2.2 meter.
LIPs for installations in unrestrained environment (concerts, ...) shall be installed at a height vertically above
the floor such that the bottom plane of the Hazard distance Zone shall be no lower than 3 meters above the
floor. Horizontal clearance to the hazard distance zone shall be not less than 2.5 meters. Any human access
horizontally to the Hazard Zone, if applicable, shall be restricted by barriers. If human access is possible in an
unsupervised environment, the horizontal or vertical clearances shall be increased to prevent exposure to the
hazard distance zone.
The LIP shall be installed by Barco or by a trained and Barco-authorized installer or shall only be transferred to
laser light show variance holders. This is applicable for dealers and distributors since they may need to install
the LIP (demo install) and/or they transfer (sell, rent, lease) the LIP. Variance holders may currently hold a
variance for production of Class IIIB and IV laser light shows and/or for incorporating RG3 LIPs. Laser light
show variance can be requested via the FDA online eSubmitter portal or via FDA Form 3147 referencing to
Barco
’
s variance approval 2016-V-0144.
The installation checklist for laser illuminated RG3 projectors must be fully completed after the installation.
The installation checklist can be downloaded from the Barco website. The last variance holder in the
distribution chain is responsible to maintain the installation checklist and to make it available on request of the
FDA. In case Barco is the last variance holder the checklist must be sent to [email protected].
Содержание UDX Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Installation manual UDX...
Страница 4: ......
Страница 28: ...R5906113 09 UDX 28 Installation process...
Страница 50: ...R5906113 09 UDX 50 Image 4 11 Installation procedures...
Страница 60: ...R5906113 09 UDX 60 Installation procedures...
Страница 72: ...R5906113 09 UDX 72 Flight case and rigging frame...
Страница 78: ...R5906113 09 UDX 78 Pulse SFP input use cases...
Страница 88: ...R5906113 09 UDX 88 Projector covers...
Страница 94: ...Glossary R5906113 09 UDX 94...
Страница 98: ...Index R5906113 09 UDX 98...