8. Service Mode
How to display the SMPS Diagnosis screen?
1. Push the cursor key
↑
or
↓
to highlight
SMPS
. (menu 8-38)
2. Press
ENTER
to select.
The
SMPS
Diagnosis screen will be displayed. (menu 8-39)
3. Press
EXIT
to return to the
Service Mode
menu.
DIAGNOSIS
I2C
FORMATTER
SMPS
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 8-38
SMPS
I2C (30H)
OK
AMBIENT TEMPERA
OK
NTC
OK
TILT SWITCH
OK
MICRO SWITCH
OK
LAMP TEMPERATUR
OK
LPS MAINS
OK
SMPS OUTPUT
OK
<EXIT> to return
Menu 8-39
8.14 DynaColor™
This menu item is only usefully when working with a multichannel setup.
To connect the projectors follow the same guidelines as discribed in Constant Light Output.
In a Linked CLO and/or Dynacolor™ setup a maximum of 14 projectors can be linked, all projectors must have
a different projector address between 0 and 13 and all projectors must have the same baudrate.
What can be done?
DynaColor™ will eliminate channel-to-channel color variations.
How to define color?
The CIE chromaticity diagram is one way to plot the colors the human eye can see.
Image 8-1
A projector can only reproduce a certain color gamut within this diagram. This color gamut is defined by the triangle formed by the
x, y coordinates of Red Green and Blue. These parameters are used by the DynaColor™ adjustment in the Trace+.
R5976781 TRACE+ 14/09/2004
137
Содержание Trace+ R9040341
Страница 1: ...Trace Owner s Manual R9040341 R5976781 00 14 09 2004 ...
Страница 4: ......
Страница 8: ...Table of contents 4 R5976781 TRACE 14 09 2004 ...
Страница 15: ...2 Packaging and Dimensions Image 2 5 Bottom View Dimensions R5976781 TRACE 14 09 2004 11 ...
Страница 16: ...2 Packaging and Dimensions 12 R5976781 TRACE 14 09 2004 ...
Страница 32: ...4 Trace Connections 28 R5976781 TRACE 14 09 2004 ...
Страница 144: ...8 Service Mode 140 R5976781 TRACE 14 09 2004 ...
Страница 146: ...9 Standard Source Files 142 R5976781 TRACE 14 09 2004 ...
Страница 150: ...Index W WARP1 43 Edit 43 WARP2 44 Edit 44 Windowing 56 Blanking 56 Start Up 56 146 R5976781 TRACE 14 09 2004 ...