3. Installation Guidelines
Image 3-7
Flip the cover to the left side and take off
How to re-adjusting the lamp position?
1. Start up the adjustment mode and select
Service
. (menu 3-1)
2. Select Lamp. The Z-axis indication (lamp menu in service mode) will be helpful while turning screw B . (menu 3-2)
3. Loosen the nut A on the back of the lamp casing (nutdriver 10).
4. Adjust the screw B with an Allen key by turning a little clockwise until the maximum light output is reached (the maximum value
of the Z-AXIS indication on the lamp menu).
5. Fasten the nut on the back of the lamp casing to secure this position (nutdriver 10).
ADJUSTMENT MODE
Select a path from below :
RANDOM ACCESS
INSTALLATION
SERVICE
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 3-1
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE PROJ. ADDRESS
CHANGE BAUDRATE PC
LAMP
MORE ...
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 3-2
LAMP
CONSTANT LIGHT OUTPUT [ON]
LINKED CLO [SLAVE]
MODE [ECONOMIC]
TARGET CLO LUMENS: 10000
_________________________________
Serial number :
003706
Article number :
R9840744
Run time :
140 hours
Remaining run time :
860
hours
Number of strikes :
160
Z-axis :
100 units
Select with
↑
or
↓
<ENTER> to toggle
<EXIT> to return
Menu 3-3
R5976781 TRACE+ 14/09/2004
17
Содержание Trace+ R9040341
Страница 1: ...Trace Owner s Manual R9040341 R5976781 00 14 09 2004 ...
Страница 4: ......
Страница 8: ...Table of contents 4 R5976781 TRACE 14 09 2004 ...
Страница 15: ...2 Packaging and Dimensions Image 2 5 Bottom View Dimensions R5976781 TRACE 14 09 2004 11 ...
Страница 16: ...2 Packaging and Dimensions 12 R5976781 TRACE 14 09 2004 ...
Страница 32: ...4 Trace Connections 28 R5976781 TRACE 14 09 2004 ...
Страница 144: ...8 Service Mode 140 R5976781 TRACE 14 09 2004 ...
Страница 146: ...9 Standard Source Files 142 R5976781 TRACE 14 09 2004 ...
Страница 150: ...Index W WARP1 43 Edit 43 WARP2 44 Edit 44 Windowing 56 Blanking 56 Start Up 56 146 R5976781 TRACE 14 09 2004 ...