background image

R5912127 /03

SP4K-B

8

Electric related safety labels

Label image

Label description

Label location

Disconnect the power to the unit mains terminals and unplug
power cord at UPS inlet before removing this cover. See ID-
label for ratings.

WARNING

: HIGH LEAKAGE CURRENT

EARTH CONNECTION ESSENTIAL BEFORE
CONNECTING SUPPLY.

SEE INSTALLATION

INSTRUCTIONS BEFORE CONNECTING TO THE
SUPPLY

.

Déconnecter l

alimentation des bornes du réseau et

déconnecter le câble de la prise UPS avant de retirer ce
couvercle. Voir l

étiquette d

identification pour les

paramètres.

ATTENTION

: COURANT DE FUITE ÉLEVÉ

RACCORDEMENT À LA TERRE INDISPENSABLE AVANT
LE RACCORDEMENT AU RÉSEAU

VOIR LA NOTICE

D

INSTALLATION AVANT DE RACCORDER AU RÉSEAU

在取下此外殼前,斷開投影機主電源端的電源並從

UPS

電源

插座上拔下電源線。 額定功率參閱產品標籤。 警告:大漏電
流,在接通電源之前必須先接地。 在連接電源前請查看安裝
說明書

在取下此外壳前,断开投影机主电源端的电源并从

UPS

电源

插座上拔下电源线。 额定功率参阅产品标签。 警告:大漏电
流,在接通电源之前必须先接地。 在连接电源前请查看安装
说明书。

Screened on Mains cover

CAUTION!

DOUBLE POLE / NEUTRAL FUSING HIGH RESIDUAL VOLTAGE -

WARNING :

RISK OF ELECTRIC SHOCK

SWITCH OFF AND UNPLUG BEFORE REMOVING THIS

COVER. SEE INSTRUCTIONS BEFORE REMOVING SMPS.

注意 兩極

/

中性熔斷 高殘餘電壓

.

警告:存在觸電風險 移除此蓋板之前, 請先關機並拔掉電源插

頭 移除

SMPS

之前,請先閱讀說明

.

ATTENTION

DOUBLE PÔLE / FUSIBLE SUR LE NEUTRE HAUTE TENSION RÉSIDUELLE -

ATTENTION : RISQUE DE CHOCS ÉLECTRIQUES

. ÉTEINDRE ET DÉCONNECTER AVANT

OUVERTURE DU COUVERCLE.

LIRE LES INSTRUCTIONS AVANT DE RETIRER LE SMPS.

Printed on SMPS cover

Only for SP4K-55B

Caution: Cable hot plugging is forbidden.

1.4 High Brightness precautions: Hazard Distance

HD

Hazard Distance (HD) is the distance measured from the projection lens at which the intensity or the energy per surface unit
becomes lower than the applicable exposure limit on the cornea or on the skin. The light beam is considered (to be) unsafe
for exposure if the distance from a person to the light source is less than the HD.

Restriction Zone (RZ) based on the HD

The HD depends on the amount of lumens produced by the projector and the type of lens installed. See chapter

HD in function of

modifying optics

page 11

.

To protect untrained end users (as cinema visitors, spectators) the installation shall comply with the following installation requirements:
Operators shall control access to the beam within the hazard distance or install the product at the height that will prevent spectators' eyes
from being in the hazard distance. Radiation levels in excess of the limits will not be permitted at any point less than 2.0 meter (SH) above
any surface upon which persons other than operators, performers, or employees are permitted to stand or less than 1.0 meter (SW)
lateral separation from any place where such persons are permitted to be. In environments where unrestrained behavior is reasonably
foreseeable, the minimum separation height should be greater than or equal to 3.0 meter to prevent potential exposure, for example by an
individual sitting on another individual's shoulders, within the HD.

These values are minimum values and are based on the guidance provided in IEC 62471-5:2015 section 6.6.3.5.

Safety

Содержание SP4K-B

Страница 1: ...ENABLING BRIGHT OUTCOMES Safety Manual SP4K B...

Страница 2: ...Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV Beneluxpark 21 8500 Kortrijk Belgium www barco com en support www barco com...

Страница 3: ...rder to protect the user or operator against risk of electric shock and energy hazard and having access to live parts Safety standards also impose limits to the internal and external temperature rises...

Страница 4: ...as to be provided with a circuit breaker of max 40A to protect the complete unit The circuit breakers are considered as readily accessible disconnect devices that must be incorporated externally to th...

Страница 5: ...leave an exclusion zone around all external surfaces of the projector whereby no flammable or combustible materials are present The exclusion zone must be not less than 40 cm 16 for this projector Do...

Страница 6: ...approved by Barco are allowed to be used For SP4K 55B do not stand on the external cooling tubes to external cooler or do not place any object on the tubes so that free liquid flow can be guaranteed P...

Страница 7: ...THE BEAM IS PERMITTED RG3 IEC EN 62471 5 2015 CLASS 1 IEC EN 60825 1 2014 HAZARD DISTANCE CONSULT SAFETY MANUAL RG3 IEC EN 62471 5 2015 CLASS 1 IEC EN 60825 1 2014 RG3 IEC EN 62471 5 2015 CLASS 1 IEC...

Страница 8: ...e distance measured from the projection lens at which the intensity or the energy per surface unit becomes lower than the applicable exposure limit on the cornea or on the skin The light beam is consi...

Страница 9: ...quirements no person is allowed to enter the projected beam within the zone between the projection lens and the related hazard distance HD This shall be physically impossible by creating sufficient se...

Страница 10: ...e distance measured from the projection lens at which the intensity or the energy per surface unit becomes lower than the applicable exposure limit on the cornea or on the skin The light beam is consi...

Страница 11: ...5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 8 5 9 9 5 10 10 5 11 11 5 12 Hazard Distance m Throw Ra o SP4K 55B SP4K 40B SP4K 35B SP4K 27BHC Image 1 4 1 7 Compliance UK Compliance UK This product is fit for use...

Страница 12: ...R5912127 03 SP4K B 12 Safety...

Страница 13: ......

Страница 14: ...www barco com R5912127 03 2021 09 01...

Отзывы: