1. Safety
1.3
Environmental Condition Check
Environment condition check
The unit must always be mounted in a manner which ensures both air inlets and outlets are free. For installations in environments
where the device is subject to excessive dust, it is highly advisable to take measures to prevent the dust from reaching the unit. If
this is not a feasible , then the unit should be relocated to a different dust-free location.
It is the customer’s responsibility to ensure at all times that the device is protected from the harmful effects of hostile airborne particles
in the environment of the device. The manufacturer reserves the right to refuse repair if a device has been subject to negligence,
abandon or improper use.
Environment conditions
Table below summarizes the physical environment in which the S3 series screen management system may be safely operated or
stored.
Environment
Operating
Non-Operating
Ambient Temperature
0°C (32°F) to 40°C (104°F)
-10°C (14°F) to 60°C (140°F)
Air cleanliness
Clean of
fi
ce environment (equivalent with cleanroom
standard ISO 14644-1 ISO Class 9)
n.a.
Humidity
5% to 85% RH Non-condensed
0% to 95% RH Non-Condensed
Altitude
-60 (-197Ft) to 3000m (9843Ft)
-60 (-197Ft) to 10000m (32810Ft)
Environment
Do not install the device in a site near heat sources such as radiators or air ducts, or in a place subject to direct sunlight, excessive
dust or humidity. Be aware that room heat rises to the ceiling; check that temperature near the installation site is not excessive.
4
R5906016 S3 SERIES 06/08/2015