15 of 149
3. TROUBLESHOOTING
3-1. RS-232 Protocol Command
Interface and Requirements
The RS-232 Commands use only ASCII characters which can be entered using a typical
terminal emulator like Windows HyperTerminal with the following setting:
Bits per second:
115200
Data bits:
8
Parity:
None
Stop bits:
1
Flow control:
None
Note that each input character will be echoed on the terminal by MCU and there is no need
to set the local echo “ON” with the terminal setting.
System Operation commands
.
The Operation commands tell the projector what to do. All commands start with 2
letters: “op” for operations commands, and a space [SP] then following a control command
then finally the value wants to read, set, increase or decrease. All commands must end
with a carriage return (ASCII hex 0D), shown as [CR] below. The syntax for operations
commands is as follows:
op
[SP]
<operation command>
[SP]
<Setting Value>[CR]
For all but Execute functions the response from the projector will be the command and
“= <value>” where <value> is the current value or “NA” if the value is not available. For
Execute functions the response will be the same command. All responses will be in CAPS.
Please refer to the following table for command list and examples:
System Operation command:
Operation
Commands
Values
Set
= <value>
Makes the unit take that value.
Get
?
Asks what the current value is.
Increment
+
Adds 1 to the current value.
Decrement
-
Subtracts 1 from the current value.
Execute
(none)
Performs an action such as a reset.
Motor operation command:
Содержание RLM-W14
Страница 1: ...1 of 149 PROJECTOR Service Manual BARCO RLM W14 Rev 01...
Страница 11: ...11 of 149 2 2 Block Diagram W14 WUXGA 3D ALL Boards Function Block Diagram...
Страница 12: ...12 of 149...
Страница 14: ...14 of 149...
Страница 38: ...38 of 149...
Страница 39: ...39 of 149...
Страница 71: ...71 of 149 4 19 All Module Layout...
Страница 83: ...83 of 149 RJ 45 Test procedures Key in your Projector IP to web browser Information...
Страница 84: ...84 of 149 5 4 Recover Process Procedure for NXP MCU...
Страница 85: ...85 of 149...
Страница 86: ...86 of 149...
Страница 87: ...87 of 149...
Страница 88: ...88 of 149...
Страница 89: ...89 of 149...
Страница 91: ...91 of 149...
Страница 92: ...92 of 149...
Страница 93: ...93 of 149...
Страница 95: ...95 of 149 3 Press the HEX File to select hex file...
Страница 96: ...96 of 149 4 Press the Change to select COM Port...
Страница 97: ...97 of 149 5 Press confirm and start to download...
Страница 100: ...100 of 149 Or please key in op soft version And you can get more detail software revision...
Страница 103: ...103 of 149 Step3 Use hexagonal wrenches to adjust first adjusting screw Movement from top left to bottom right...
Страница 104: ...104 of 149 Step4 Use hexagonal wrenches to adjust second adjusting screw Movement from bottom left to top right...
Страница 105: ...105 of 149 Step5 Use hexagonal wrenches to adjust third adjusting screw Movement from bottom left to top right...
Страница 120: ...120 of 149 7 3 Replacing the Lamp...
Страница 121: ...121 of 149...
Страница 122: ...122 of 149...
Страница 123: ...123 of 149 7 4 Replacing the Filter...
Страница 124: ...124 of 149...
Страница 125: ...125 of 149...
Страница 137: ...137 of 149 ACCESSORIES 1 W14 BLK RLM W14 REMOTE CONTROLLER 26KEYS R5001519K 2 ACCESSOR KIT RLM W14 NO battery TBD...
Страница 138: ...138 of 149 9 PRODUCT PACKAGING 9 1 Full set unit packaging...
Страница 139: ...139 of 149 9 2 Model Accessory Part...
Страница 140: ...140 of 149 9 3 Carton...
Страница 141: ...141 of 149 9 4 Serial NO Label Explanation...
Страница 142: ...142 of 149 9 5 AIR SEA Shipping Packaging...